Skip to the record
Noosa’s premier civic archive.

Council archive · source document

09/1474 - Preliminary Building Works [As Published] · 172009.1474

of 23

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

Ne

a

 

 

 

 

 

0.42 bmt colorbond ultra roof sht. at 4.65m
radius fixed to manuf. spec.

75x38 (variable) battens fixed by 1/75mm
No. 14 type 17 screw

approved roof trussés at 90Qcrs.
fixed by 30x0.8 galv. looped

  

 

 

 

1

|
!

Sermemer f

ee

| q

 

 

2/M12 bolts from
200x45 Hyne LVL beam
to 150x100x10 galv. plate
, plate fully welded to
B 100 CHS galv. columns

provide powder coated TT]
alum slatted screen l

slab

to conc.

between posts JIM
_—
at
Y16 brace rods
fully welded to {
columns [L| 2/M12 bolts from plate
rT |

 

=F

 

 

 

 

 

 

 

 

 

190. blockwork . .
reint. to Y reinf. conc. slab & footing
Ena’s details details to Eng.s drawings
9 ‘Kordon’ termite protection to
Z all slabs & slab penetrations
[Ly on compacted sand fill
Typical Details
Scale 1: 20
NOTES . wes

All levels/dimensions shall be verified on site before commencing work.
Use figured dimensions only. Scaling dimensions is not to be used. All
« workmanship/materials to be in accordance with relevant SAA codes
and the Qld. Building ‘Act. Footing/slab design to be designed by
* engineers. .
Timber, sized from AS1684(N3) — MGP12-H2 (JD4 group) ext. loadbearing swd. walls
MGP10SH2 (JD4 group) int./non-load swd. walls. Hyne 18C/F17hwd lintels/beams

F18 laminated beams. Terrain Cat. 2.5 Topographic class - T1

~

2/M12 bolts from
245x65 Hyne 18C lam:

beam

to 150x200x10 galv. plate

plate fully welded to
100 CHS galv. columns

2-way from
entry area ¢
of house

 

 

sensor
units to
lights

/

re: dop
XX PN

 

 

o.

Carport Electrical Plan

 

Type
fluorescent fight (strip with sensor))

Symbol

tr

paraflood light (with sensor)

double power point

 

 

 

2 (external)
|

1 (external)

 

 

 

 

 

 

   

proposed Carport
forMr & Mrs Doyle

at Lot 15
Plover Street
PEREGIAN BEACH

 

amendments

 

 

 

/ OPRIAN POOLEY »

aad
MS8OGATES.
ply Kd-..
ACH. 010 700 289"*
building designed:
alex seaside resort
cnr alexandra parade & mari street
alexandra headland tel.
07-5443 2173
} design FAX
adrian pootey — )7-54438320
drawn scale
ahp:mep 4:100/20
date drawing
28/09/09

9/2087 /30-3

        

   

Building Design
(restrictions - nil)
Licence No - 64684

   
 

building designers
association of

 

Lic. under QBSA Act 1991.

 
   

queensland ine.
\ life_member

 

    

 

 

 

 

 

 

 

Used in these records

About this file

File size
1.7 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

09_1474 - Preliminary Building Works [As Published].pdf · 1.7 MB (small file)