Council archive · source document
Response to Information Request - REC13/0015
Very large file (44.8 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.
PRE DEVELOPMENT Q100 Cooroy stg noosa 100-Year Duration=6 min, Inten=301.0 mmlhr
Prepared by {enter your company name here} Printed 19/04/2013
HydroCAD<ID 10.00 sIn 05328 @2011 HydroCAD Software Solutions LLC Page 7
Summary for Subcatchment 55: Existing roof+drive area
Runoff = 0.02080 [email protected] hrs, Volume= 0.010 MI, Depth= 37 mm
Runoff by Rational method, Rise/Fall=1.0/1.7 xTc, Time Span= 0.00-3.00 hrs, dt= 0.01 hrs
noosa 100-Year Duration=6 min, Inten=301.0 mm/hr
Area (m2) C Description
276.0 0.90 existing roof+DVE
276.0 100.00% Pervious Area
Tc Length Slope Velocity Capacity Description
(min) (meters) (m/m) (m/sec) (m3/s)
5.0 Direct Entry, existing roof
5.0 0.0 Total, Increased to minimum Tc = 6.0 min
Subcatchment 55: Existing roof+drive area
Hydrograph
II Runoff~
-
~
E
-
~
o
LL
o 1 2 3
Time (hours)
See the original
The page text is free to read. Viewing or downloading an original file needs an account.