Council archive · source document
RFI - Attachment 6 - Amended Civil Engineering Report · MCU22/0094
Very large file (15.5 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Original PDF page 50, section 1. The text section number identifies this passage in the reader.
WATER SENSITIVE DESIGN CODE
Performance Criteria and Acceptable Solution
Noosa Childcare Centre Lot 4
11 May 2022
PERFORMANCE OUTCOMES ACCEPTABLE OUTCOMES RESPONSE
Shire Business Centre
PO5 AO5.1 RO5.1
Within the Shire Business Centre site, as shown on No probable solution Not Applicable
Map SBC run-off treatment is contained within the
developable areas of the site and drainage lines are
only used for final polishing of run-off;
AND
PO6 AO6.1 RO6.1
Within the Shire Business Centre site, as shown on No probable solution Not Applicable
Map SBC, on-site detention measures are
contained within the developable areas of the site,
clear of drainage lines and Open Space Precincts
Use of natural treatments and systems
PO7 AO7.1 RO7.1
Natural treatment strategies, including grass swales No probable solution Development complies. Bioretention basin will be
and bio-retention systems, vegetated filtration strips utilised
and gross pollutant traps, are used wherever
possible..
PO8 AO8.1 RO8.1
Development design including density and scale Integration of stormwater quality treatment is in Development complies. Bioretention basin will be
provides adequate footprint to integrate all elements accordance Healthy Waterways Water Sensitive Urban utilised
of stormwater quality and quantity treatment Design Guidelines for South East Queensland and the
infrastructure including, where relevant, bio Water by Design Bio retention Technical Design
retention basin batters and maintenance access, Guideline.
without the need for retaining walls.
PO9 AO9.1 RO9.1
Stormwater conveyance channels use natural Landscape and ecological features (e.g. plant species No new conveyance channels constructed as part
channel design principles to convey external and habitat types) used in stormwater conveyance of the development
catchment stormwater through the development channels are complementary to the local context,
including natural waterways;
l:\9000-9999\9300-9399\9307\codes\11-05-22 water sensitive design code.docx
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
RFI - Attachment 6 - Amended Civil Engineering Report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 15.5 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.