Original source · versioned page text
Noise Report
Density Residential Zone or High Density
Residential Zone and screened by a 5 metre wide
buffer densely planted with trees and shrubs
including species from 1 metre to 8 metres in
height; or
(b) located internally to the arrangement of buildings
on the site.
AO22.4
Mechanical plant is:
(a) located at least 2 metres from side or rear
property boundaries;
(b) where located at ground level, screened by fencing
1.5 metres in height or dense vegetation of at least
1.5 metres in width incorporating grouped trees
and shrubs with a maximum separation distance of
1 metre measured from the centre of the plant;
(c) where located above ground level, enclosed or
screened such that it is not visible from the street
frontage nor adjoining properties; and
(d) visually integrated into the line and plane of the
building and roof design and does not project
beyond the height or width of the building when
viewed from the street and adjoining properties.
Onsite accommodation and potential noise intrusion can be addressed during the detailed design stage
(façade treatment) and operational noise managed by onsite management.
It is recommended that compliance is achieved with Acceptable Outcome AO22.4 for mechanical plant with
minimum boundary setbacks (2m) and screened by ground level fencing (min. 1.5m high) and screened for
above ground level plant.
5.2 Environmental Protection (Noise) Policy
Schedule 6 Planning scheme policies part SC6.2 - PSP1 Preparing a well-made application, SC6.2.4 Appendix
1, states that noise emissions from onsite activities are assessed against the Environmental Protection (Noise)
Policy 2008 (EPP 2008). Details of the criteria and established noise limits are presented in the following
sections.
5.2.1 Acoustic Quality Objectives
Table 4 presents the acoustic quality objectives at noise sensitive receivers as detailed in Schedule 1 of the
EPP2008.
Table 4: Acoustic Quality Objectives at Noise Sensitive Receivers (EPP2008)
Acoustic Quality Objectives, dB(A)
Sensitive Receiver Time of Day
L Aeq,adj,1hr L A10,adj,1hr L A1,adj,1hr
Dwelling Day and Evening
50 55 65
(Outdoors) (7am – 10pm)
Site: 3 - 7 Serenity Place, Noosa 11
Reference: 22BRA0079 R01_1