DETAILS OF MAIN BUILDING DETAILS OF MAIN COMPONENTS
Bay Width: 4 x 4.000 m Roof Cladding: 0.42 Corro bmt - 0.48 Corro tct
Span: 8.000 m Wall Cladding: 0.42 Corro bmt - 0.48 Corro tct
2C25024 "C" Purlin, Fixed with heavy duty plates
Length(total): 12.000 m Columns:
and bolts
2C25024 "C" Purlin, Fixed with heavy duty plates
Eave Height: 4.200 m Rafters:
and bolts
Overall Height: 4.978 m
TH120100 purlin fixed with heavy duty framing
Roof Pitch: 11 deg Purlins:
teks
Left Lean-to: N/A Girt: TH120100 girt fixed with heavy duty framing teks
Right Lean-to: N/A Gutter: Quad
Front Garaport: 0.000 m Downpipes: To ground level
Back Garaport: 0.000 m
Note: Garaport length is included in Length(total) shown above.