Figure 4.4 – Typical Tank node configuration
Each tank is to be fitted with a first flush diverter to remove the typically sediment laden
initial volume from the tanks. This is modelled by assuming a 25L flush for run-off draining
to each tank distributed over the roof area equating to a 0.12mm increase to the rainfall
threshold on the upstream roof source node.
The tanks will be plumbed for internal and external reuse which has been modelled in
accordance with the MUSIC guidelines. The reuse demands have been determined as
follows.
- Internal Reuse
o All homes are assumed to be fitted with full water saving devices,
▪ 26L/Person/day for laundry
▪ 21L/Person/day for toilets
o ½ Pod C roof run-off
▪ 2x2 bed = 3.2 persons
▪ 3.2 * 47L = 150.4L/day
Page 14 of 26