Council archive · source document
Att 4 - SWMP · MCU21/0117
4.2.2 Operational Maintenance
Periodic maintenance and monitoring of stormwater infrastructure proposed for this
development should be carried out to ensure they are operating effectively during the
post-construction phase. After the on-maintenance period, the responsibility for these
maintenance activities shall be the body corporate for the site who may appoint a suitably
qualified maintenance contractor to undertake these activities.
The field inlet grates, pits and underground pipes shall be inspected for blockage or
damage at least 6 monthly or after significant rainfall event. Any blockages shall be
cleared from the system, and damage assessed to determine if it impacts on the function
of the system or may pose a hazard that will require repair.
The litter baskets shall be maintained in accordance with the manufacturer’s specifications.
Refer to Appendix C Ecosol Litter Basket Technical Specification for further details.
The bioretention areas shall be maintained following a schedule of routine inspections
undertaken after every significant rainfall event (30mm of rainfall in a 24-hour period) or on
a three (3) monthly basis within the first twelve (12) months and on a six (6) monthly basis
thereafter. The inspection shall ensure the proper functioning and condition of the
bioretention area and ensure that the planting and vegetation health is suitably
maintained. An inspection checklist from the Healthy Waterways Technical Design
Guidelines for Southeast Queensland has been provided in Appendix D Bioretention
Inspection Checklist that provides the structure for the inspections to be undertaken.
In addition to regular inspections, the first 4 months of establishment of the bioretention
areas requires a watering frequency of:
i. Week 1 - 6 - 5 times per week
ii. Week 6-10 – 3 times per week
iii. Week 11-15 – 2 times per week
After 5 months, watering frequency shall be adjusted based on the local conditions to
ensure plants are maintained in a healthy state.
Page 18 of 26
P +61 7 5211 1003 A 37 Mary St, Noosaville Qld 4566 E [email protected] recorconsulting.com
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Att 4 - SWMP.pdfRelated documentApplication case desk ↗
About this file
- File size
- 5.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.