FLOOR AREAS - UNIT 1 & 2 COLOURBOND ROOF

SHEETS

: ‘INTERNAL GROUND: 65.2 sq.mx 2 = 130.4 sq.m

Coe RN DENSITY: 5 porns INTERNAL UPPER: 54.3 sq.mx2= 108.6 sq.m ; HOSE TAP STORM WATER
‘ . FLOOR GULLY

PLOT RATIO: 0.45:1 | TOTAL GFA: 239.0 sq.m / 239.2 sq.m | LOOR GULL SMOKE DETECTOR

SITE COVER x 40% 212.6 sq.m PLOT RATIO: 0.45:1 /0.45:1 DOWN PIPE HOT WATER

GROSS FLOOR AREA x 45% 239.2 sq.m TOTAL SITE COVER: 208.6 sq.m / 212.6 sq.m FRIDGE

2 ! DOOR
LANDSCAPED OPEN SPACE 4.8p x 40m? 192.0 sq.m OPEN LANDSCAPE AREA: 220.4 sq.m/192.0 sq.m FLAT ROOF

SOFT LANDSCAPE: 192.0 x 60% = 115.2 8q.m/ 124.4 sq.m WINDOW
HARD LANDSCAPE: 192.0 x 40% = 76.8 sq.m/ 97.6 sq.m RAIN HEAD rates von

AIR-CON UNIT SPITTER

 

 

 

 

 

 

TBM
Nail in Kerb
RL 38.94

TOP OF ROOF-RL-48-45--

_400h SEMI-FRAMELESS GLASS.
BALUSTRADING ATTACHED TO
FRAMEWORK INNER FACE AS
HREQD) NO TOBHOUDS 1) i!

 

Me eee nneee

 

 

TOP OF ROOF RL 47.10

 

: LOT 1 RP160353
20 BELMORE TERRACE SUNSHINE BEACH “ROOFS ON SITE

AREA: 531.6 m?

1
0} DOWN PIPES AND ROOF DRAINAGE LOCATIONS
ARE SUGGESTED ONLY AND BUILDER SHOULD

ENSURE ADEQUATE STORMWATER FALL AND
3850 | DRAINAGE AS REQUIRED

 

 

NOOSA SHIRE COUNCIL

PLANS AFHROVE

SITE ADDRESS: Lot 1 RP 160353 20 Belmore Terrace, Sunshine Beach

CHRIS CLOUT DESIGN PTY LTD GENERAL NOTES: CLIENT NAME: IRWINN Glenn & MATHEWS Trevor
CHRIS CLOUT

12 WEYBA ST SUNSHINE BEACH Use written dimensions only. DO NOT scale drawings. Contractors to verify all

dimensions on site prior to commencing works. Site location is Category W41or
design PO BOX 135, NOOSAVILLE, QLD 4566. to engineers requirment. ° “oy prawins tre: ROOF TERRACES

PH: (07) 54748 107 FAX: (07) 54748 108 wrese drawings are "0 be read m conjunction with engineers design and details, DRAWING DATE: 26/06/07 SCALE: 1:100 DRAWN BY: ¢ clout DRAWING Na:
Pty Ltd MOB: 0412 408 410 EMAIL: [email protected] accompanying buliding specification and schedule of rinishes. 04 0
If in doubt, please request clarification. DO NOT ASSUME. AMENDMENT bates: PRELIMINARY 15-02-08 '

 

 

Used in these records

About this file

File size
1.9 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_2357 - Approved Plans [As Published].pdf · 1.9 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.