RADIATA PINE ROOF TRUSSES @ 900 CRS FITTED IN
20 DEGREES PITCH ROOF & ACCORDANCE WITH MANUFACTURER'S SPEC.
TOP HAT PITCH 30 DEGREES WITH FEATURE GUTTER COLOURBOND ROOF SHEETS FITTED IN ACCORDANCE
( SEE JOINERY DETAIL ) ae MANUFACTURER'S SPEC. FOR W41 WIND LOADS.
ENSURE WATERPROOF MEMBRANE
PROPERLY TO TIMBER FRAMED
ROOF TERRACE TO ENGINEERS DETAILS
8MM RENDER WITH
FINE SAND FINISH WITH 8MM x 8MM
GAPS AT 140 HORIZ. LINES
3 COATS OF
WATERPROOF TYPE PAINT
120 x 45mm K/D DURABILITY CLASS 1 EXPOSED
RAFTER TAILS WHERE SHOWN.
(SCHEDULE OF FINISHES)
i
-yrra
ta
UPPER CEILING LINE
a 's
° we FA
5 5 2 >
< S0MM TIMBER FRAME TO is 5
= WITH WALL & ;
* CLADDING (TBA :
_UPPERFLOORLEVEL _ RL 44.25 fH eee EE LLL LLL Ln m ) ~-eL- LLL z _ '
ea MS eH ee ee ee ee LL LL LLL wees -3
UPPER FLOOR LEVEL
i Fy
'
t
1
1
t
.
GROUND CEILING LINE COT OT TON
200 SERIES BLOCKWORK TO = GROUND CEILING LINE
8 ENGINEER'S DETAILS :
8 :
o ENSURE PARAPETS TO PLANTERS {
8 ARE PROPERLY WATERPROOF YI
GROUND FLOOR LEVEL ~\J RL 40.95
“BASEMENT CELINGLINE ~ “B77 7 7 7 7 TTT Se ~ — ~ RE449 KA | GRounp FLoor LeveL
Op GSE TTT a NP ie UK KL BASEMENT CEILING LINE
= —
RL 38.25
BASEMENT FLOOR LEVEL
200 UM WATERPROOF MEMBRANE
TREATMENT AGAINST TERMITE
ATTACK (TERMIMESH OR SIMILAR)
REINFORCED CONCRETE
SLAB AND FOOTINGS
TO ENGINEER'S DETAILS Ss E cTi QO N B B
RADIATA PINE ROOF TRUSSES @ 900 CRS FITTED IN ENSURE WATERPROOF MEMBRANE
20 DEGREES PITCH ROOF & ACCORDANCE WITH MANUFACTURER'S SPEC. PROPERLY TO TIMBER FRAMED 120mm TOP SPAN
TOP HAT PITCH 30 DEGREES WITH FEATURE GUTTER COLOURBOND ROOF SHEETS FITTED IN ACCORDANCE ROOF TERRACE TO ENGINEERS DETAILS METAL PURLIN WITH 7 DEGREES.
( SEE JOINERY DETAIL ) WITH MANUFACTURER'S SPEC. FOR W41 WIND LOADS. ROOF PITCH 10MM RENDER WITH
FINE SAND FINISH
) SKYLIGHT ACCESS HATCH 3 COATS OF
120 x 45mm K/D DURABILITY CLASS 1 EXPOSED
RAFTER TAILS WHERE SHOWN. ~_) WATERPROOF TYPE PAINT
(SCHEDULE OF FINISHES) NS
5
L
TERRACE t ’ ‘ - pee eee ey el.
RL 46 po Gee LI
“UPPER CEILING LINE “*
90MM TIMBER FRAME TO ' * t ' “ne ‘ ‘ ; : '
WITH WALL —_ . . fay 5 a = 40 ~ “T9_ sh <7 UPPER FLOOR LEV
CLADDING (TBA) to | . vt teed — . : — WO ay ‘GROUND Sensis
UPPER FLOOR LEVEL RL 43.75
“GROUND CEILING LINE
200 SERIES BLOCKWORK TO.
ENGINEER'S DETAILS
' : BED 2
, . ENSURE PARAPETS ARE PROPERLY '
: WATERPROOF \
GROUND FLOOR LEVEL RL 40)45 RL 40.45 GROUND FLOOR LEVEL
“BASEMENT CEILING LINE
---- SA PARKING
TIMBER
DOORS AND WINDOWS TO W41
AS PER ENGINEERS DETAILS
BASEMENT FLOOR LEVEL
Rt 37.75
200 UM WATERPROOF MEMBRANE
TREATMENT AGAINST TERMITE
ATTACK (TERMIMESH OR SIMILAR)
ALL FRAMING TIMBER MEMBER SIZES ETC.
AS PER ENGINEERS DETAIL
SECTION AA
REINFORCED CONCRETE
SLAB AND FOOTINGS
TO ENGINEER'S DETAILS
CLIENT NAME:
SITE ADDRESS: Lot 1 RP 160353 20 Belmore Terrace, Sunshine Beach
GENERAL NOTES: IRWINN Glenn & MATHEWS Trevor
CHRIS CLOUT DESIGN PTY LTD
CHRIS GLOUT
ZA 12 WEYBA ST SUNSHINE BEACH Use written dimensions only. DO NOT scale drawings. Contractors to verify all
a LJ dimensions on site prior to commencing works. Site location is Category W41or
design PO BOX 135, NOOSAVILLE, QLD 4566. to engineers requirment, 9 prawinc tie: SECTIONS AA
PH: (07) 54748 107 FAX: (07) 54748 108 These drawings are to be read in conjunction with engineer's design and details, DRAWING DATE: 26/06/07 DRAWN BY: c clout DRAWING No:
Ply Ltd MOB: 0412 408 410 EMAIL: [email protected] the accompanying building specification and schedule of finishes. 0 7 0
amenpMenT vates: PRELIMINARY 15-02-08 ,
If in doubt, please request clarification. DO NOT ASSUME.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/2357 - Approved Plans [As Published]Related documentApplication case desk ↗
About this file
- File size
- 1.9 MB (small file)
- File type
No other editions are linked here.