Council archive · source document
Y010-01 AAA Stormwater Report · OPW21/0219
Attached to the e-mail Engineering documentation - 12 Grosvenor Terrace OPW21/0219.
AAA DESIGN & DEVELOPMENT PTY LTD ABN 33 109 041 287 Unit 34, 13 Norval Court Maroochydore QLD 4558 Tel/Fax.: (07)5479 6747 Mobile: 0422 039 247 Email: [email protected] 23rd June 2022 12 Grosvenor Tce Noosa Heads Qld 4567 Application No; OPW20/0172 Our Ref: Y010-01 In Accordance with the Information Request Dated 3 September 2021. 1. Please refer to the attached survey plan (Appendix A) of the hard stand area for 12 Grosvenor Terrace. This provided the basis for the attached engineering drawings (Appendix B) demonstrating the runoff direction and corresponding volume calculations as requested. 2. As the attached drawing (Appendix B) shows, the watershed over the existing driveway for 12 Grosvenor Terrace can be divided into two distinct catchment areas. The first area is defined by CTM1, whereas the water drains towards the existing inlet pit in the North East Corner of the property (Indicated by the arrows). The second area is defined by CTM2, which flows towards the kerb into the road reserve. The flow calculations in Appendix B for ‘CTM2’ determined that even under a major flood (1% AEP) the maximum depth at the invert of the kerb will only rise 25mm. The cross fall for driveway of Number 12 is 150mm (See Attachment A). Also consider the height difference between the driveway at Number 14 and Number 12 is an additional 70mm (See Attachment C). Hence, waterflow from driveway at number 12 will not top the high point in the driveway of number 14 Grosvenor Terrace. 3. Formal statement; Based on the evidence stated above, I, Jose David Lesmes Tirado (RPEQ7198), certify the downstream Driveway at 12 Grosvenor Terrace, Noosa Heads does not impede surface flows for all events up to and including the 1% AEP to such an extent that flows will not top the highpoint in the driveway to Number 14 Grosvenor Terrace. 4. Construction Management Plan 4.1 The aim is to cut between the existing kerb and bitumen edge to replace the original kerb with M3. This will be done along the front boundary of 12 Grosvenor Tce. 4.2 In order to prevent water seepage between the existing bitumen and the kerb, an asphalt repair compound will be used to sealed the gap between the bitumen and the new kerb (Refer to Appendix B). 4.3 The traffic management plan will be organised by the owner at 12 Grosvenor Tce. Do not hesitate to contact us, if there are any queries. Regards Jose David Lesmes Tirado BEng Civil, MIEng Aust, RPEQ 7198 pg. 1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 1 page
Page 2
AAA DESIGN & DEVELOPMENT PTY LTD
ABN 33 109 041 287
Unit 34, 13 Norval Court
Maroochydore QLD 4558
Tel/Fax.: (07)5479 6747
Mobile: 0422 039 247
Email: [email protected]
Attached Appendix
Appendix A ………. Contour Survey by Noosa Cooloola Land Surveys, Project No. 22338Det.
Appendix B ………. Stormwater Calculations by AAA Design and Development Dwg 3847.
Appendix C ………. 14 Grosvenor Tce Engineering by Lindsay Consulting, Dwg 20-1000-F1.
pg. 2
Used in these records
Y010-01 AAA Stormwater Report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 168 KB (small file)
- File type
No other editions are linked here.