                                                                                                                                                                                                                  PROFILED METAL ROOF SHEETING ON                  PREFABRICATED STEEL PFC WALKWAY                                                                      TENANCY ENTRY STATEMENT
                                                                                                                                                                                                                  INSULATION BATTENS & PURLINS                     ARBOR STRUCTURE w/ DANPALON (OR                                                                      TO FUTURE DETAIL
                                                                                                                                                                                                                  FRAMING TO STRUCTURAL ENG. DETAIL                SIMILAR) USED FOR ROOF SHEETING

                                                                                                                                                                                                                                                                   CONC. TILT PANEL WALL
                                                                                                                                                                                                                                                                   REFER STRUCTURAL ENG. DETAIL




                                                                   ROOF
                                                               10.200 m




                                                                LEVEL 1                                                                                                                                                                                                                                                                                                 SIGNAGE PANEL FIXED TO FEATURE TIMBER
                                                                6.000 m                                                                                                                                                                                                                                                                                                 BLADES TO FUTURE DETAIL


                                                                                                                                                                                                                                                                   TENANCY 21

                                                                                                                                                                                                                                                                   TENANCY SHOPFRONT                                                                                    CARPARK
                                                          GROUND FLOOR
                                                               3.000 m



                                                                                                                                                                                                                                                                                                                                  PEDESTRIAN WALKWAY HARDSCAPING
                                                                                                                                                                                                                                                                                                                                  ELEMENT TO FUTURE DETAIL. REFER TO PLAN
                                                                                                                                                                                                                                                                                                                                  FOR LAYOUT
                                                                                                                                                                     CONCRETE TILT WALL TO                                                                         R.C FLOOR SLAB AND FOOTINGS TO
                                                                                                                                                                     FUTURE DETAIL                                                                                 STRUCTURAL ENG. DETAIL                                         PEDESTRIAN WALKWAY



                                                              1           BUILDING 3 - Section c
                                                          A-DA-1203 1 : 100




                                                                                                                                                                                                                                                                                          3075


                                                                                                                                                                                                                                                      TENANCY ENTRY STATEMENT                        PROFILED METAL ROOF SHEETING ON
                                                                               1100




                                                                                                                                                                                                                                                      TO FUTURE DETAIL                               INSULATION BATTENS & PURLINS
                                                                                                                                                                                                                                                                                                     FRAMING TO STRUCTURAL ENG. DETAIL

                                                                                                                                                     TENANCY 22
                                                                           3800
                                                                        2700   1100
                                                                           3800




                                                                                                                                                     CURTAIN WALL GLAZING
                                                                                                                                                     TREATMENT TO EXTERIOR
                                                                        2700




                                                                                                                                                                                                                                                                      9645
                                                                15000


                                                                               1100




                                                                                                                                                     TENANCY SHOPFRONT w/ INTEGRATED
                                                                                                                                                     MULTI-FOLD DOORS TO FUTURE DETAIL
                                                                           3800
                                                                        2700




                                                                                                                                                                                                                                                                                                     CONC. TILT PANEL WALL
                                                LEVEL 1                                                                                                                                                                                                                                              REFER STRUCTURAL ENG. DETAIL
                                                6.000 m



                                                                                                                                                                                                                                                                                                     TENANCY 02
                                                                                                                                                                                                                                                                      3000
                                                                        2800




                                                                                                                                                                                    ARBOR STRUCTURE FOR SHADING
                                                                                                                                                                                                                                                                                                     TENANCY SHOPFRONT
                                           GROUND FLOOR
                                                3.000 m




                                                                                                                                        PEDESTRIAN WALKWAY                                                         CARPARK                                                      PEDESTRIAN WALKWAY




                                                              2           MIXED-USE PRECINCT OVERALL SITE SECTION - d
                                                          A-DA-1203 1 : 100




Rev.   Date       Description   Iss.   Appr.                                          Do not scale this drawing. Verify all dimensions on site before commencing                                                                   Project                                                                     Status                                                       Drawing Title

                                                                                                                                                                                                                                   NOOSA MARKETPLACE
                                                                                      any work. Copyright © 2019 Buchan. This drawing remains the property of
1      14.05.19   FINAL ISSUE   AJ     PS
                                                                                      The Buchan Group Australia Pty Ltd. Reproduction in whole or in part without
                                                                                      prior consent is forbidden.                                                                                                                                                                                              Date Plotted
                                                                                                                                                                                                                                                                                                                              14/05/2019 11:09:23 AM
                                                                                      File
                                                                                                                                                                                                                                   LOT.1 - SP222982: 2-20 HOFMANN DRIVE, LOT.4 - SP2465848:                    Date Issued
                                                                                                                                                                                                                                                                                                                              14.05.19
                                                                                                                                                                                                                                                                                                                                                                 N          MIXED-USE PRECINCT BUILDING
                                                                                                                                                                                                                                   2-18 HOFMANN DRIVE, NOOSA QLD                                               Scale
                                                                                                                                                                                                                                                                                                                              1 : 100 @A1                                   SECTIONS
                                                                                                                                                                                                                                   Project Number                                                                                                                           Drawing Number                      Revision   Brisbane Studio
                                                                                                                                                                                                                                                                                                               0        10       20             40       60M
                                                                                                                                                                                                                                                                                                                                                                                                                           + 61 7 3859 9222 / buchangroup.com.au
                                                                                                                                                                                                                                   716159                                                                                                                                   A-DA-1206                               1
Log in to download the original file

13. Appendix I - Integrated Water Mangement Plan.pdf · 61.2 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.