Skip to the record
For the highest quality transcripts.

Council archive · source document

Approved Plans - MCU22-0135 · MCU22/0135

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
              NOOSA COUNCIL
              APPROVED PLAN
            MCU22/0135 7 OCT 2022




                                                                                                                                                                                                                                                                                                                                              Selected EPS sunhood/feature fixed
                                                                                                                                                                                                                                                                                                                                              to manufacturers specification.
                                                                                                                                                                                                                                                                                                                                              (Rendered & Painted)

                                                                                                                                                                                                                                                                                                                                              Colorbond Custom orb roof sheeting
                                                                                           Select Timber Cladding fixed to                                                                                                                                                                                                                    fixed to manufacturers specification
                                                                                           manufacturers specification.                                                                                                                                                                                                                       for required wind category. (5° pitch).
                                                                                                                                                    600                                                                  600
                                                                                           Rendered NRG Foamboard to                                O/H                                                                  O/H
                                                                                           manufacturers specification.                                                                                                                                                                                                                       Rendered brick veneer
                                                                                                                                                                                                                                                                                                                                              walls to engineers details.
                                                                                                                                                                                                  5°
                                                                                                                                                                                                                                                                                                                                              Colorbond slotted gutter, fascia
                                                                                           Select Recycled Brickwork wall to                                                                                                                                                                                                                  to match roofing. Fix to manufacturers
                                                                                           owners / builders specification.                                                                                                                                                                                                                   specification.
                                                                                           Aluminum framed Doors
                                                                                           to manufacturers specification.
                                                                         Parapet Height*
                                                4,725mm




                                                                 4740




                                                                                                                                                                                                                                                                                                                                                       Parapet Height*
                                                                                                  Ceiling Height




                                                                                                                                    6,734mm




                                                                                                                                                                                                                                                                                                                                                3340
                                                                                           2700




                                                                                                                          Joinery
                                                                                                                   2400




                                                                                           2x 89 Nom.CHS Post                                                                                                                                                                                                                                 Approx. Existing
                                                                                           to engieers detail.                                                                                                                                                                                                                                Ground Line.
                                                                                           Nom. 200 thick concrete pool                                                                                                                                                                                                                       Approx. Proposed
                                                                                           walls to engineers detail.                                                                                                                                                                                                                         Ground Line.
                                                                                           Approved frameless glass pool fence to                                                                                                                                                                                                             Aluminum framed windows
                                                                                           manufacturers specifications.                                                                                                                                                                                                                      to manufacturers specification.
                                                                                           Min. 1200mm high.
                                                                                                                                                                                                                                                                                                                                              Rendered 600mm Cantilevered
                                                                                           30x30 Aluminium Batten Screen                                                                                                                                                                                                                      Slab Edge to engineers detail.
                                                                                           @ 75mm Crs Max. fixed to
                                                                                           manufacturers detail.
                                                                                           Built up rendered 200 series
                                                                                           blockwork wall to engineers detail.

                                                                                                                                                                                                                             NORTH EAST ELEVATION
                                                                                                                                                                                                                             Scale : 1 : 100




                                                                                                         Revision Schedule                     Project Address :                                                                Sheet Name:                                                   Project Status:               Project Number:                              * Parapet heights are dependent on the truss upstand.
                                                                                                  Number Description    Date Issued by         No. 49 Donnellys Road, Ridgewood                                                 Elevations                                                    WD                            20-060                                       Builder to confirm truss upstands with truss
                                                                                                  1     WD           20/01/20 BJH                                                                                                                                                                                                                                        manufacturers prior to building parapet walls to ensure
                                                                                                                                            Client Name :                                                                         Project Issue Date :                                                Q.B.C.C Lisence No.   Sheet Number:                                roofing & adequate flashing is hidden behind parapet walls.
    Email: [email protected]
    Website: www.iconbuildingdesign.com.au                                                                                                  Rhys          &   Monique                                                             20/01/2021                                                          126221                07
Document    Set ID: 22061202
     C COPYRIGHT The Drawing and the design depicted on this sheet remains the property of Icon Building design. Reproduction in part or whole is prohibited unless written permission is obtained from Icon Building Design. Plans are design for use on the job address specified in the titleblock only.
Version: 1, Version Date: 04/08/2022

Used in these records

About this file

File size
4.8 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Approved Plans - MCU22-0135.pdf · 4.8 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.