APPROVED WITH CONDITIONS
This is an Approved Building Works Document. Refer
FRAMELESS GLASS to the Decision Notice for conditions of approval
A B C D BALUSTRADE TO BE PERMIT No. 35484
DESIGNED AND DATE 09/11/2023
APPROVED BY
BOUNDARY
CONCRETE ROOF TO ENGINEERS DESIGN AND ISSUED BY COASTAL BUILDING
DETAIL (TED). APPLY WATERPRROFING OVER - STRUCTURAL CERTIFICATIONS PTY LTD
WATERPROOF MEMBRANE TO BE 'DURAM 195
WATERPROOFING MEMBRANE'. WHERE EXPOSED CONCRETE ROOF - ENSURE ENGINEER
TO ELEMENTS, THE MEMBRANE IS TO BE TOPPED MIN. 1:100 FALL IS ACHIEVED
WITH 'MULTITHANE ATC'.
50 250
UPPER FLOOR PP RL 26030 UPPER FLOOR PP RL 26030
8m HEIGH
T LIMIT FR
GLASS SKYLIGHT TO SPEC (SDD) OM DETA
IL SURVEY
2700
W13
2500
2500
FORMED CONCRETE DAYBED SLAB TO
2450
2400
D11
ENGINEERS DESIGN AND DETAIL (TED)
DINING
BOUNDARY
DAYBED
UPPER FLOOR RL 23530 RL 23530 RL 23530 UPPER FLOOR RL 23530
250
300
300
1080
GROUND FLOOR PP RL 23230 GROUND FLOOR PP RL 23230
1580
FORMED
VOID POOL RECESSED ACRYLIC POOL WINDOW TO
SPEC (SDD) CONFIRM RECESS DEPTH WITH
SUPPLIER PRIOR TO ORDERING
D1
50
3000
3000
2750
'DOUBE SKIN' POOL SHELL TO ENGINEERS
DESIGN AND DETAIL (TED)
STAIRS
GLASS BALUSTRADE ON STAND OFF PINS TO
2400
730mm D6 SPEC. ENSURE FINISHED HEIGHT IS MIN.
GROUND FLOOR RL 20230 1000mm ABOVE FINISHED FLOOR LEVEL GROUND FLOOR RL 20230
RL 20230 TERRACE
FAMILY
300
780 300
300
LOWER FLOOR PP RL 19930 LOWER FLOOR PP RL 19930
300
ENSURE WATERPROOFING TO
WALLS IN ACCORDANCE WITH CONCRETE BEAM TO ENGINEERS DESIGN
300
MANUFACTURERS STANDARDS AND DETAIL (TED)
3480
3480
AND COMPLY WITH ASA AND BSA EXISTING
STAIRS GROUND
2700
LI NE FROM line of
2450
TERMITE BARRIERS TO BCA 3.1.3 200UM D3 DETAIL SU sewer
RVE Y
WATERPROOF MEMBRANE TREATMENT AGAINST
TERMITE ATTACK (TERMIMESH OR SIMILAR) FAMILY
LOWER FLOOR RL 16450 LOWER FLOOR RL 16450
RL 16450
FRAMELESS GLASS
SECTION 3 BALUSTRADE TO BE
SCALE: 1 : 100 DESIGNED AND
APPROVED BY
STRUCTURAL
ENGINEER
A B C D
PLANTER - ENSURE SUFFICIENT
BOUNDARY
DRAINAGE. TO HYDRAULIC ENGINEERS
DESIGN AND DETAIL
CONCRETE ROOF - ENSURE
MIN. 1:100 FALL IS ACHIEVED
50 250
UPPER FLOOR PP RL 26030 UPPER FLOOR PP RL 26030
350
8m HEIGH
T LIMIT FR
OM DETA
IL SURVEY
OREGON BOARD FORMED FRAMELESS GLASS POOL FENCE ON
2700
2500
2500
SPIGOTS TO SPEC
2400
CONCRETE WALL TO ENGINEERS W15 W16
DESIGN AND DETAIL (TED) PDR
LIVING
BOUNDARY
UPPER FLOOR RL 23530 RL 23530 FALL
UPPER FLOOR RL 23530
250
300
300
GROUND FLOOR PP RL 23230 POOL GROUND FLOOR PP RL 23230
300
RECESSED ACRYLIC POOL WINDOW TO
ALL SUSPENDED SLABS TO MAX. DEPTH 1.08m SPEC (SDD) CONFIRM RECESS DEPTH WITH
ENGINEERS DESIGN AND DETAIL (TED) SUPPLIER PRIOR TO ORDERING
50
3000
3000
2750
D4 'DOUBE SKIN' POOL SHELL TO ENGINEERS
DESIGN AND DETAIL (TED)
70mm
BED 2 ENS BED 3 ENS GLASS BALUSTRADE ON STAND OFF PINS TO
2400
D5
SPEC. ENSURE FINISHED HEIGHT IS MIN.
GROUND FLOOR RL 20230 1000mm ABOVE FINISHED FLOOR LEVEL GROUND FLOOR RL 20230
RL 20230
GUEST
300
780 300
300
TERRACE
LOWER FLOOR PP RL 19930 RL 19500 LOWER FLOOR PP RL 19930
300
ENSURE WATERPROOFING TO
WALLS IN ACCORDANCE WITH ALL CONCRETE BEAMS TO ENGINEERS
MANUFACTURERS STANDARDS DESIGN AND DETAIL (TED)
3480
3480
AND COMPLY WITH ASA AND BSA
2750
2700
EXISTING line of
TERMITE BARRIERS TO BCA 3.1.3 200UM COMMS PDR GUEST ENS STUDY D2 GROUND
LI NE FROM sewer
WATERPROOF MEMBRANE TREATMENT AGAINST DETAIL SU
RVE Y
TERMITE ATTACK (TERMIMESH OR SIMILAR)
LOWER FLOOR RL 16450 LOWER FLOOR RL 16450
RL 16450
SECTION 4
SCALE: 1 : 100
CLIENT: Maxine Horne PROJECT: BEACHES
www.chriscloutdesign.com.au GENERAL NOTES:
Use written dimensions only. DO NOT scale drawings. Contractors SITE ADDRESS: BEACHES NOOSA 7/56 David Low Way, SUNRISE BEACH QLD 4567
A: OFFICE 1/20 DUKE STREET, to verify all dimensions on site prior to commencing works. Site
SUNSHINE BEACH, QLD 4567, location in accordance with engineers details. These drawings are to DRAWING TITLE: SECTIONS
be read in conjunction with engineers design and details, the
E: [email protected] DATE: 31-08-23 SCALE: 1 : 100 @ A2 DRAWN BY: C.CLOUT
P: (07) 54748 107 BSA LICENCE: 1127508
accompanying building specification and schedule of finishes. If in
doubt, please request clarification. DO NOT ASSUME. ISSUE: PRELIMINARY WORKING DRAWINGS
W3.1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
35484 APPROVED PLANS BA.pdfRelated documentApplication case desk ↗
About this file
- File size
- 18.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.