1 INTRODUCTION SCG Consulting Engineers has performed a limited site investigation and established a site classification in accordance with AS 2870-2011 and made recommendations based upon the classification for a building to be constructed at the above site. This report does not include an assessment of Slope Stability, Landslide Risk, or specifications for damp proofing, termite protection or moisture barriers. This soil test and footing report relates only to the above property and the proposed construction as described below: Proposed Construction Residential Dwelling External Walls Masonry Internal Walls Masonry/Timber Ground Floor Slab on Ground Upper Floor Suspended Concrete Building Platform Cut Pad Masonry Articulation Required @ 8 m centres This report must be read and considered as a whole. All of our recommendations, foundation plans, sections and appendices must be read, considered and followed by all people involved in this project including the client to ensure adequate long term performance of the footing system constructed on this site. A copy of this report must remain with the client or final owner of the building upon completion of the proposed works. If you are unsure of any of the requirements herein, you must seek clarification from this office. 2 SITE CLASSIFICATION After considering the results of our field investigation performed on 21/02/2022 we have classified this site in accordance with AS 2870-2011 as: The classification has been calculated from test work performed on the soil profile encountered on the day of our fieldwork and consideration of AS2870-2011. Any disturbance of the soil profile may result in a change to the classification. The ‘P’ classification relates to the loose sands and poor bearing capacity encountered during our testing on site. Please refer to our definitions list appended to this report for further descriptions of these characteristics. With respect to potential surface movements through seasonal moisture variations, the site could be considered equivalent to a class S site. The site preparation details that follow have allowed for the influence of the earthworks described in section 5.0 below. Site Classification: The site classification is calculated in accordance with the “AS2870-2011 Residential Slabs and Footings-Construction” and relates to the estimation of Ys, “The characteristic surface movement” within reactive soil profiles. The limits used for this classification are as follows: | Predicted Surface Movement __| Classification | Ys = <=20mm S Slight Ys = >20— 40mm M Moderate Ys = >40 — 60mm H1 High-1 Ys = 60 —75mm H2 High-2 Ys => 75mm E Extreme Problem sites Pp Problem 3 SITE DESCRIPTION The construction area has a gradient in the order of 5%. SCG Consulting Engineers 1 SCG Ref: 32027(S)
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
35484 APPROVED PLANS BA.pdfRelated documentApplication case desk ↗
About this file
- File size
- 18.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.