0008783052-01 NatHERS Certificate 6.1 Star Rating as of 24 Jul 2023
Explanatory notes
AAOs have specific quality assurance processes in place, and continuing
About this report professional development requirements, to maintain a high and consistent
A NatHERS rating is a comprehensive, dynamic computer modelling standard of assessments across the country. Non-accredited assessors do not
evaluation of a home, using the floorplans, elevations and specifications to have this level of quality assurance or any ongoing training requirements.
estimate an energy load. It addresses the building layout, orientation and Any questions or concerns about this report should be directed to the
fabric (i.e. walls, windows, floors, roofs and ceilings), but does not cover the assessor in the first instance. If the assessor is unable to address these
water or energy use of appliances or energy production of solar panels. questions or concerns, the AAO specified on the front of this certificate should
Ratings are based on a unique climate zone where the home is located and be contacted.
are generated using standard assumptions, including occupancy patterns and
thermostat settings. The actual energy consumption of a home may vary Disclaimer
significantly from the predicted energy load, as the assumptions used in the
The format of the NatHERS Certificate was developed by the NatHERS
rating will not match actual usage patterns. For example, the number of
Administrator. However the content of each individual certificate is entered and
occupants and personal heating or cooling preferences will vary.
created by the assessor to create a NatHERS Certificate. It is the
While the figures are an indicative guide to energy use, they can be used as a responsibility of the assessor who prepared this certificate to use NatHERS
reliable guide for comparing different dwelling designs and to demonstrate that accredited software correctly and follow the NatHERS Technical Notes to
the design meets the energy efficiency requirements in the National produce a NatHERS Certificate.
Construction Code. Homes that are energy efficient use less energy, are
The predicted annual energy load in this NatHERS Certificate is an estimate
warmer on cool days, cooler on hot days and cost less to run. The higher the
based on an assessment of the building by the assessor. It is not a prediction
star rating the more thermally efficient the dwelling is.
of actual energy use, but may be used to compare how other buildings are
likely to perform when used in a similar way.
Accredited assessors
Information presented in this report relies on a range of standard assumptions
To ensure the NatHERS Certificate is of a high quality, always use an (both embedded in NatHERS accredited software and made by the assessor
accredited or licenced assessor. NatHERS accredited assessors are members who prepared this report), including assumptions about occupancy, indoor air
of a professional body called an Assessor Accrediting Organisation (AAO). temperature and local climate.
Australian Capital Territory (ACT) licensed assessors may only produce Not all assumptions that may have been made by the assessor while using the
assessments for regulatory purposes using software for which they have a NatHERS accredited software tool are presented in this report and further
licence endorsement. Licence endorsements can be confirmed on the ACT details or data files may be available from the assessor.
licensing register
Glossary
Annual energy load the predicted amount of energy required for heating and cooling, based on standard occupancy assumptions.
the floor area modelled in the software for the purpose of the NatHERS assessment. Note, this may not be
Assessed floor area
consistent with the floor area in the design documents.
features that require a penetration to the ceiling, including downlights, vents, exhaust fans, rangehoods, chimneys
Ceiling penetrations and flues. Excludes fixtures attached to the ceiling with small holes through the ceiling for wiring, e.g. ceiling fans;
pendant lights, and heating and cooling ducts.
a zone within a dwelling that is expected to require heating and cooling based on standard occupancy
Conditioned
assumptions. In some circumstances it will include garages.
windows listed in NatHERS software that are available on the market in Australia and have a WERS (Window
Custom windows
Energy Rating Scheme) rating.
windows that are representative of a specific type of window product and whose properties have been derived by
Default windows
statistical methods.
these signify ventilation benefits in the modelling software and must not be modelled as a door when opening to a
Entrance door
minimally ventilated corridor in a Class 2 building.
terrain with no obstructions e.g. flat grazing land, ocean-frontage, desert, exposed high-rise unit (usually above 10
Exposure category – exposed
floors).
terrain with few obstructions at a similar height e.g. grasslands with few well scattered obstructions below 10m,
Exposure category – open
farmland with scattered sheds, lightly vegetated bush blocks, elevated units (e.g. above 3 floors).
terrain with numerous, closely spaced obstructions below 10m e.g. suburban housing, heavily vegetated bushland
Exposure category – suburban
areas.
Exposure category – protected terrain with numerous, closely spaced obstructions over 10 m e.g. city and industrial areas.
provides shading to the building in the horizontal plane, e.g. eaves, verandahs, pergolas, carports, or overhangs
Horizontal shading feature
or balconies from upper levels.
National Construction Code the NCC groups buildings by their function and use, and assigns a classification code. NatHERS software models
(NCC) Class NCC Class 1, 2 or 4 buildings and attached Class 10a buildings. Definitions can be found at www.abcb.gov.au.
the openability percentage or operable (moveable) area of doors or windows that is used in ventilation
Opening percentage
calculations.
an assumed value that does not represent an actual value. For example, if the wall colour is unspecified in the
Provisional value documentation, a provisional value of ‘medium’ must be modelled. Acceptable provisional values are outlined in
the NatHERS Technical Note and can be found at www.nathers.gov.au
can be applied to walls, roofs and ceilings. When combined with an appropriate airgap and emissivity value, it
Reflective wrap (also known as foil)
provides insulative properties.
for NatHERS this is typically an operable window (i.e. can be opened), will have a plaster or similar light well if
Roof window
there is an attic space, and generally does not have a diffuser.
Shading device a device fixed to windows that provides shading e.g. window awnings or screens but excludes eaves.
Shading features includes neighbouring buildings, fences, and wing walls, but excludes eaves.
the fraction of incident solar radiation admitted through a window, both directly transmitted as well as absorbed
Solar heat gain coefficient (SHGC) and subsequently released inward. SHGC is expressed as a number between 0 and 1. The lower a window’s
SHGC, the less solar heat it transmits.
Skylight (also known as roof lights) for NatHERS this is typically a moulded unit with flexible reflective tubing (light well) and a diffuser at ceiling level.
U-value the rate of heat transfer through a window. The lower the U-value, the better the insulating ability.
a zone within a dwelling that is assumed to not require heating and cooling based on standard occupancy
Unconditioned
assumptions.
provides shading to the building in the vertical plane and can be parallel or perpendicular to the subject
Vertical shading features wall/window. Includes privacy screens, other walls in the building (wing walls), fences, other buildings, vegetation
(protected or listed heritage trees).
* Refer to glossary. Page 15 of 15
Generated on 24 Jul 2023 using BERS Pro v4.4.1.5 (3.21) for David Low Way , Sunrise Beach , QLD , 4567
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
35484 APPROVED PLANS BA.pdfRelated documentApplication case desk ↗
About this file
- File size
- 18.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.