Performance outcomes                           Acceptable Outcomes                           Comments
Street awnings Cooroy and Tewantin                                                           Not applicable.
PO30                                           AO30                                          The site is not within this locality.
Street awnings in Cooroy and Tewantin          Street awnings:
District centres are designed and located
to:                                                   1. are provided along the
                                                         full frontage of the building and
        1. provide continuous weather                    cover the footpath where no
           protection to pedestrians;                    other weather protection is
        2. maintain the continuity and                   provided for pedestrians as part
           style of adjacent awnings,                    of the building design;
           especially in relation to height,          2. are set back a minimum of 1
           scale, form and materials;                    metre from the kerb and where
        3. contribute to an attractive                   include timber posts, the posts
           streetscape environment;                      are set back not less than 1
        4. promote an                                    metre from the kerb;
           active building front by                   3. are water proof;
           encouraging pedestrian use of              4. conform with the height, form
           the street;                                   and materials of awnings on
        5. provide a feeling of enclosure                adjoining properties which
           and human scale for                           share the same frontage;
           pedestrians so as to contribute            5. where fall towards the street,
           to the “sense of place”; and                  are no less than 2.5 metres at
        6. have an adequate clearance                    their lowest point or where
           distance from the kerb to                     cantilevered, are no less than
           prevent obstruction.                          2.7 metres at their lowest point




Urban Planners Queensland
[email protected] | upqld.com.au | (07) 3106 3221
Log in to download the original file

Attachment B - Code Compliance Assessment.pdf · 868 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.