Attachment B - Code Compliance Assessment
Performance outcomes Acceptable Outcomes Comments
seating areas are in the line of sight or seen The proposal is located within an existing
from a street or other public space. Building Unit Plan. These services were
provided as part of the parent approval.
Lighting Complies with Performance Outcome.
PO15 AO15.1 The proposal is located within an existing
The obtrusiveness of lighting is minimised Lighting associated with the use is designed, Building Unit Plan. These services were
without unduly limiting the use, enjoyment installed, operated and maintained in a provided as part of the parent approval.
or safety of outdoor recreation community manner that does not unreasonably impact
facilities. on the amenity of an adjoining residential
use.
AO15.2
Any lit sports courts are located at least 60
metres from the external wall of an existing
or approved residential dwelling on any
separate property (as measured from the
centre of the court).
AO15.3
The vertical illumination resulting from
direct, reflected or other incidental light
emanating from the site does not exceed 8
lux when measured at any point 1.5 metres
outside the boundary and at any level
from ground level upward; and any flood
lighting is restricted to the types that give no
upward component of light where mounted
Urban Planners Queensland
[email protected] | upqld.com.au | (07) 3106 3221
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.