Council archive · source document
08/0658 - Operational Works - Road and Drainage/S/Wter/Water and Sewerage [As Published] · 142008.658
- SEWGR NOTES PIPELINES 1. ALL SEWERS ARE TO BE 150 @ uPVC CLASS SN8 - AS1260 - RUBBER RING JOINTED , UNLESS NOTED OTHERWISE. FOR SEWERS DEEPER THAN 3.0 m, uPVC CLASS 12 PRESSURE PIPE TO AS1477 SHALL BE USED. INSIDE EOGE OF CLASS 12 PIPE TO BE CHAMFERED TO PROVIDE A SMOOTH TRANSITION OF FLOWS WHEN USED IN CONJUNCTION WITH OTHER CLASSES OF PIPES AND FITTINGS. 2. ALIGNMENTS UNLESS NOTED OTHERWSSE SHALL BE: 2.1. 1.50m INSIDE FRONT BOUNDARY OF ALLOTMENTS 2.2. 1.50m INSIDE REAR BOUNDARY OF ALLOTMENTS 2.3. 1,00m FROM SIDE BOUNDARY OF ALLOTMENTS 3. BEDDING FOR PIPELINES TO BE TYPE 1 UNLESS OTHERWISE NOTED AND PLACED IN ACCORDANCE WITH NOOSA SHIRE COUNCIL STANDARD DRG. No. 8813. IN COASTAL SAND TERRAIN , EXCAVATED MATERIAL MAY BE USED FOR BEDDING SUBJECT TO THE APPROVAL OF THE SHIRE ENGINEER. ALL OTHER AREAS SHALL USE WASHED 5mm - 10mm SCREENINGS AS BEDDING AND BACKFILLING MATERIAL. 4. MINIMUM COVER FOR SEWER PIPES SHALL BE 1.0 METRE FOR ALLOTMENTS AND FOOTPATHS , AND 1.5 METRES FOR ROADWAYS HOUSE CONNECTION BRANCHES 5, THE FOLLOWING CRITERIA ARE TO BE TAKEN INTO ACCOUNT WHEN SETTING THE INVERT LEVEL OF AN HCB... 6. HOUSE CONNECTION JUMP-UPS ON SEWERS DEEPER THAN 2.0m SHALL BE “SUGDON” FIBREGLASS REINFORCED DROP JUNCTIONS. 5.1. DEPTH TO INSPECTION OPENING SHALL BE BETWEEN 0.6m AND 1.5m 5.2. INSPECTION OPENING SHALL CONTROL THE ALLOTMENT AT A GRADE OF 1 IN 60 5.3. WITH 300mm COVER AT HEAD OF DRAIN §.4. (C) DEPTHS IN EXCESS OF 1.5m ARE NOT ACCEPTABLE 7. HOUSE CONNECTION BRANCHES TO EXTEND AT LEAST 1.5m INTO PROPERTY BEING SERVED. 8. ALL HOUSE CONNECTION BRANCHES TO BE TYPE A, P OR F AND CONSTRUCTED IN ACCORDANCE NOOSA SHIRE COUNCIL STANDARD ORG. No. 9821H. 9, HOUSE CONNECTION BRANCHES TO BE 100mm DIAMETER UNLESS NOTED OTHERWSSE. WORK ON EXISTING SEWERS 10. ALL WORK ON EXISTING SEWERS TO BE PERFORMED BY APPROVED CONTRACTOR UNLESS OTHERWISE DIRECTED BY THE SHIRE ENGINEER , AND ACTUAL COST INCLUDING LABOUR AND MATERIALS SHALL BE MET BY THE DEVELOPER. SEWER MANHOLES 7/04/2008 10:43:23 AM 44. MANHOLES SHALL BE PRE-CAST 1070mm DIA. UNLESS OTHERWISE NOTED AND CONSTRUCTED IN ACCORDANCE WITH NOOSA SHIRE COUNCIL STANDARD DRAWINGS Nos, 0822¢, 9843 & 9848a. : 1. GENERAL NOTES ALL WORK IS TO BE CARRIED OUT TO THE STANDARDS OF, AND TO THE APPROVAL OF THE NOOSA COUNCIL AND THE ENGINEER. THESE DRAWINGS ARE TO BE READ IN CONJUNCTION WITH THE NOOSA SHIRE COUNCIL STANDARD DRAWINGS : 9813 SEWER CONSTRUCTION TRENCHES & BEDDING 9821H HOUSE CONNECTION BRANCHES - 9822C SEWER MANHOLES 9843 DUCTILE IRON SEWER MANHOLE COVERS 9848A SEWER MANHOLE - PRECAST COMPONENTS AND BASE PROPERTY BOUNDARIES SHALL BE STAKED PRIOR TO SEWERAGE CONSTRUCTION AND SEWERAGE MANHOLE LOCATIONS CHECKED SY CONTRACTOR TO ENSURE BOUNDARY CLEARANCES ARE ACHIEVED - THE CONTRACTOR SHALL NOT RELY SOLELY ON SEWER CHAINAGES TO SET OUT MANHOLES. FINAL SURFACE LEVELS OF MANHOLES ARE TO BE ADJUSTED ON SITE TO SUIT ALL EARTHWORKS. - TYPICALLY 75mm ABOVE SURROUNDING FINISHED SURFACE LEVELS. THE CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL EXISTING SERVICES BEFORE COMMENCEMENT OF WORK ON SITE. ALL TRENCH EXCAVATION AND CONSTRUCTION IS TO BE IN ACCORDANCE WITH THE CONSTRUCTION SAFETY ACT 1971-1975 AS AMENDED, AND THE MINES REGULATIONS ACT. PROVECT PROPOSED INDUSTRIAL SUBDIVISION VENTURE DRIVE, NOOSAVILLE for GATEWAY RISE PTY LTD DRAWING TITLE SEWERAGE RETICULATION NOTES ASSOCIATED CONSULTANT PROJECT STRATEGY QLD Pty Ltd 1 041898 96 57 Meble Telephone Fecsimie Eroad Address + [email protected]: : 62 Buderim Avenue, Alexandra Headird OLD 4572 TODCORNSULT. ENGINEERS 20 Mary Street, Noosaville P.O. Box 61, Noosaville QLD 4566 Phone (07) 5449 9600 Fax (07) 5449 9494 EMail: [email protected] Web: www.todconsulting.com eee are, Devlan and Orme Ty 14 tt Ont MAR 2008 = “ MURRAY & ASSOCIATES STRUCTURAL CIVIL = Saki reete COW'S ts Sas come McGrath RPEQ 3029 | “MAS SHO! LOT 14 ON SP170295 . CONSULTING SURV meee. || Cononor mY chonceano! sumo, PUANERS, mae a Ga saa A Fe Commruraord WEYBA eR ce Oa a lary counts of Y Semen nem HORIZ DATUM Gaps toeneY oe (G7) sa 7OGas rom To SULTING PTY. LTD. eee COUNTY OF MARCH VERT DATUM —_BM 108352 mee ee Serr an ° on 39 128 605 336 vane 06583 wes , Ti TI messes, NOOSA COUNCIL APPROVAL No 2007/1626 RL 3.818 AHD ee }
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
08/0658 - Operational Works - Road and Drainage/S/Wter/Water and Sewerage [As Published]Related documentApplication case desk ↗
About this file
- File size
- 3.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.