column 1 ees Column 3
Specific Outcomes Probable solutions (if code assessable) Compliance
c) 0.45:1 otherwise.
O09 For Multiple housing Type 3 or 4, Visitor
accommodation Type 4 or the accommodation unit Complies — A maximum gross floor area of 2201.6m? is
component of an Entertainment and dining business allowable. The proposal has a gross floor area of 757m’.
Type 3 (hotel)—the maximum gross floor area is
equivalent to the maximum allowable population density in
persons multiplied by 40m’, provided that Lots 75-77 on
P9311 Heron Street, Peregian Beach, have a maximum
gross floor area of 1200m’.
010 For the Detached Housing Zone and Semi- Complies - soft landscaping is provided over a large area of
attached Housing Zone—soft landscaping is provided and the site. It is noted that this requirement has been Seleted as
retained over a minimum of 20% of the site area. part of the proposed planning scheme amendments.
011 For the Neighbourhood Centre Zone the maximum
plot ratio is as follows—
a) 0.8:1 for site areas up to and including 2000m?: and
b) 0:3:1 for that area of a site in excess of 2,000m’.
Roof form
O13 Roof forms— $13.1 The main roof of the building has a roof pitch no less Complies — The project designer has incorporated a variety of
a) contribute positively to the local skyline; than 5 degrees and has roof overhangs a minimum of 600mm skillion roof forms across the proposal. These have a pitch
b) complement the beachside character of the wide; greater than 5 degrees and include overhangs a minimum of
locality: AND 600mm wide.
Cc) use soft and articulated pitched or curved roof $13.2 Buildings and structures do not include roof top terraces.
forms;
d) avoid low pitched (eg. less than 5 degrees) or box
profiles/parapets; and
e) do not create opportunities for residents to
overlook the private open space areas of
neighbouring properties.
Sloping sites
O14 Development on sloping sites— $14.1 Buildings and associated accessways are not Not Applicable — The subject is not defined as a sloping site.
a) is responsive to the natural topography of the site constructed on land with a slope greater than 25% (1 in 4); It is noted that as a result of the backfilling of the lower level,
and minimises cut and fill; AND the project designer has ensured the topographical
b)} does not visually dominate the hill slope or $14.2 Buildings are of split level design that step down the characteristics of the site improve the acoustic and visual
interrupt the skyline; slope or have suspended floor construction; amenity outcomes of the development.
¢) is integrated with the natural site characteristics AND
including vegetation; and $14.3 Cut or fill is less than 1.5m in depth;
d) for Multiple housing, takes the form of small AND
separate buildings. $14.4 The distance between the ground and the lowest part of
the floor of the building does not exceed 3m to avoid large
under-building areas;
AND
$14.5 Buildings present no more than—
a) if in the Visitor Mixed Use Zone —- 3 storeys at any one
point when viewed from the street; orSee the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
0015ECF3.001.pdfRelated documentPublic source context ↗
07/1685 - MCU - Visitor Accom. Type 4 - Visitor Hostel [As Published]Related documentApplication case desk ↗
About this file
- File size
- 6.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.