Specific Outcomes Probable solutions {if code assessable) Compliance
DAWENAY PY
% f i Vf f ‘. YN
Oth 1 i Y +. &
Cra4G aS 75 } ae. 16.
a oy — CTH - ee $5.1 Landscaping provided which allows adequate visibility for | Conditions may be recommended accordingly.
Fi , ae EEC casual surveillance of public and semi-public spaces, including
Re c ne entrances and exits to sites and buildings, by:
Visionl a) planting trees which have clean trunks to a height of at
RoAtun least 1.8 m; and
¥ b) appropriately spacing shrubs at 1.2m horizontal centres,
with a maximum height of 0.75m, to avoid clumping and to
O5 The provision of landscaping is to a satisfactory retain sightlines.
standard ensuring that it does not lead to opportunities for
concealment and possible assault sites. $6.1 Street trees and trees in carparking areas achieve a Conditions may be recommended accordingly.
maximum of 900mm clear trunk height for a 2.0m high tree at
planting and are able to attain a clear trunk height of 1900mm on
maturity;
$6.2 All scrub planting to be a maximum height of 700mm from | Conditions may be recommended accordingly.
the road pavement (not top of kerb).
O6 Street trees and plantings in towns and villages,
carparks and other areas where potential conflicts with
vehicles and pedestrians are evident, are planted so as to
maximise vehicle and pedestrian safety.
Services and utilities
07 ~All landscaping works maintain adequate safe S7.1 Plant species used in landscaping adjacent to substations, | Conditions may be recommended accordingly.
distance from services and utilities including substations, or adjacent to or on electricity transmission line easements, are
overhead powerlines, power poles and transformers, street less than 4m high at maturity and do not encroach within 3m of a
lamps, stormwater catchment pits, and underground substation boundary;
services and utilities. OR
S7.2 For trees higher than 4m, trees are planted at a distance
from any part of an electricity transmission line at least equal to
the expected height of the tree at maturity (see Figure -2;
Figure -2
bees |
$7.3 For power lines that connect to a premises, the height ofSee the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
0015ECF3.001.pdfRelated documentPublic source context ↗
07/1685 - MCU - Visitor Accom. Type 4 - Visitor Hostel [As Published]Related documentApplication case desk ↗
About this file
- File size
- 6.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.