Skip to the record
The gold standard in government transparency.

Council archive · source document

07/2357 - MCU - Multiple Housing Type 2 - Duplex [As Published] · 132007.2357

of 74

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

Column 4
Specific Outcomes

014 Multiple housing is designed and sited to minimise the
extent of shadows cast on solar photovoltaic cells on roofs of
adjoining buildings.

Stoping sites

O15 On sloping sites, buildings and structures are designed
to maximise the use of the natural topography and minimise the
need for cut and fill.

Wall length and detailing

O16 Within the Semi-attached Housing, Attached Housing
and Visitor Mixed Use Zones buildings and other structures
provide for visual interest and amenity by—

a) staggering or separating continuous walls into smaller
sections to vary the elevation; and
b) _ providing well articulated building forms with strong

 

vertical design features.

Column 2
Probable Solutions (if code assessable)

   

DETAILED ELEVATION — THE MEASUREMENT AT *.” IS
50% OF THE WIDTH OF THE SOUTHERN PROPERTY.
IT’S NOT AFFECTED BY SHADOWS FROM THE
NORTHERN NEIGHBOUR, EVEN IN THE MIDDLE OF
WINTER WHEN THE SUN IS LOW.

$14.1 No solution provided

 

$15.1 Buildings and structures on sloping sites—

a) Have a maximum distance of 3m between the
ground and the lowest part of the floor of the building
or the building incorporates undercroft skirting or
screening (eg. timber battens) to the full height of any
undercroft area higher than 3m above ground level at
the perimeter of the building:

are of split level design that step down the slope or
have suspended floor construction;

limit the amount of cut or fill to less than 4.5m in
depth; and

b)
c)

qd)
of the building and associated batters.

$16.1 The maximum wail length is 15m;

AND

$16.2 Wall pianes incorporate design elements to add visual
interest and amenity, such as windows, pergolas, sun
shading devices and variations in balcony styles.

 

do not result in the spread of fill beyond the footprint

  
  

 

Column 3
fereTiare cures

  
 

Not applicable.

Not applicable.

—|

Complies — the proposa! has a maximum length of wall less
than 15metres. Wall planes incorporate visual design elements
such as windows, feature grooves and a range of balcony styles.

 

 

 

For Muitiple housing Type 2 - Duplex

 

Orta
ber rey

 

yea
Built Form
| Garages and carports
O17 Garages, carport structures and vehicle manoeuvring

Residential Code - Glen Irwin and Trevor Mathews

column 2
Probable solutions {if code assessable)

| 517.4 Where lock up garages are included—

bere TE
Compliance

 

| Basement carparking proposed.

Page 5

Used in these records

About this file

File size
6.6 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_2357 - MCU - Multiple Housing Type 2 - Duplex [As Published].pdf · 6.6 MB (large file)