Our ref: 102995-10


Earthworks

    Issue
    The proposed development will include significant earthworks but the submitted material does not include any
    comment, plans or reports regarding the extent of earthworks and the proposed retaining structures.

    Information Required

    9.    Provide detail and plans that clearly indicate the extent of earthworks and the proposed retaining structures. The
          detail must also include a site specific soils investigation that includes recommendations for the construction of
          the development works.


Response
Earthworks plans (prepared by Acor) have been provided in Attachment C. These plans show the extent of
all earthworks and retaining structures. They have been designed in accordance with the Stormwater
Management Plan.
It is submitted to Council that a site specific soils investigation be conditioned as part of development
approval that will better contemplate detailed design.


Traffic and Access

    Issue
    There will be a demand for customers to use both centres in the same trip and for this reason there should be
    integration between the two buildings for cars, pedestrians and service vehicles.

    Information Required

    10. Provide amended plans that address and provide for the following:
        a. Redesign the proposal to integrate the vehicular access arrangements (car and service vehicle) and
            pedestrian connectivity of the proposed Bunnings expansion with the existing Bunnings development.
          b.   Demonstrate how vehicles would safely and appropriately exit the existing northern Bunnings access
               driveway and then enter the proposed new Bunnings expansion driveway.

          c.   Quantify and justify the loss of on-street parking arising from the proposed access arrangements.
          d.   Demonstrate that a delivery vehicle entering the new driveway will have adequate height clearance where it
               passes under the new building.
          e.   Justify one-way operation of the proposed basement carpark when the preferred two-way operation can be
               readily accommodated.




Response
Traffic response has been prepared by TTM confirming the appropriateness of the proposed design, access
and circulation arrangements. In particular TTM indicate that:
•        Integration of the site access arrangements is not physically possible due to the substantial difference in
         levels between the two sites, being approximately 3m.
•        TTM drawing number 21BRT0226-04B (Appendix B of the traffic report) demonstrates that the design
         customer vehicle (large car and dual-axle trailer combination) can safely and adequately exit the
         existing Bunnings northern access on Gateway Drive.




RPS Australia East Pty Ltd. Registered in Australia No. 44 140 292 762
rpsgroup.com                                                                                                           Page 14

Used in these records

About this file

File size
1.9 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

MCU220051_Information Request Response_v1.2_130323.pdf · 1.9 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.