Log in to see the plans as drawn(a) the court is located at least 60
metres from the external wall
of an existing or approved
dwelling on adjoining or
nearby premises (as
measured from the centre line
of the court); and
(b) the vertical illumination
resulting from direct, reflected
or other incidental light
emanating from the site does
not exceed 8 lux when
measured at any point 1.5
metres outside the boundary
and at any level from ground
level upward; and
(c) any floodlighting is restricted
to the types that give no
upward component of light
where mounted horizontally
(i.e. a full cut off luminare).
AO22.3
Outdoor or semi-enclosed
common areas used for serving
or drinking alcohol, or designated
outdoor smoking areas are:
(a) setback at least 15 metres
from the boundary of land in a
Low Density Residential
Zone, Medium Density
Residential Zone or High
Density Residential Zone and
screened by a 5 metre wide
buffer densely planted with
trees and shrubs including
species from 1 metre to 8
metres in height; or
(b) located internally to the
arrangement of buildings on
the site.
AO22.4