Note:
This plan was prepared as a site contour and detail
survey of 2 Arakoon Crescent, Sunshine Beach, Qld,
N T 4567 and it should not be used for any other purpose.
Lot boundaries were not marked at the time of survey
E 785 and have been derived from survey plan's RP48111,
SC
IS304495, IS295771, IS177648, SP137632, IS156867,
IS159182, IS95399 & IS29170 Held by Department of
RP48111
E Resources. Bearings shown on the plan have been
CR
rotated by 8°46'20" to be in terms of MGA2020 z56.
ON
Services shown hereon have been located by field
survey where possible. Prior to any excavation,
K O demolition or construction the relevant authorities
should be contacted for locations of underground
A services if applicable.
AR For detailed information please refer to digital models.
Survey File: M4371 3000 001 A.12da & .dwg
This note is an integral part of the plan.
784
RP48111
0
27.0
5 0 5
N
0
26.0
109° Scale 1 : 250 - Distances are in Metres
16'2
35.8 0"
351°27'2
ISSUE/REVISION
0
25.0
58
14.120
CP
D
Located Services Note:
0"
ROA
0
24.0
SP148678
Service information shown on this plan has been surveyed to AS 5488.1:2019
Classification of Subsurface Utility Information standards.
23.00
Quality Level A - Consists of the positive identification of the attribute and location A 25/05/22 Issued to client
of a subsurface utility at a point to an absolute spatial position in
Rev Date Revision Details
.00
three dimensions. It is the only quality level that defines a subsurface
22
utility as "validated."
Quality Level B - Relative subsurface feature location in three dimensions 783 CONSULTING
0"
21.00
by tracing or physical measurement that does not satisfy
RP48111 CADASTRAL
16'2
0
the spatial tolerance of Quality Level A. The minimum requirement
7
ENGINEERING
20.0
8.06
199°
for Quality Level B is relative spatial position. MINSTAFF AND MINING
0
19.0
Quality Level C - Surface feature correlation or an interpretation of the approximate SURVEY SURVEYORS
ABN 35 609 674 875
location and attributes of a subsurface utility asset using a
combination of existing records, a site survey of visible evidence
26.00
and/or methods to indicate the existance of an undefined entity. TOOWOOMBA SUNSHINE COAST BRISBANE
338
Quality Level D - The attribute information and metadata of a subsurface utility 319 Margaret Street 22/2 Innovation Parkway 4/8 Navigator Place
may be from any or a combination of: existing records, cursory Toowoomba QLD 4350 Birtinya, QLD 4575 Hendra, QLD 4011
14.1
°39
(07) 4637 9790 (07) 5327 3900 (07) 3198 2462
site inspection, and anecdotal evidence.
25.00
'50"
20
CLIENT
A comprehensive search has been made of the works area, however due to
age, type and depth of services, and soil/ground conditions, it is recommended
that appropriate physical validation is completed prior to any excavation,
24.00
demolition, or construction.
THE
0
.0
LEGEND
23
00
22.
00
FEATURE DESCRIPTION FEATURE DESCRIPTION
21.
0
ESP
20.0
Building FACIA Building SHED PROJECT
Building WALL Building STAIRS
2 Arakoon Crescent
ROAD
CM Communications MARKER Communications PIT
Drainage APRON CP Drainage KERB ADAPTOR Proposed Development
LAN
P PO
D D
Drainage DOWN PIPE Drainage PIPE OUTLET
SP148681 Lot 783 on RP48111
32 4.12
Drainage GULLY TRAP Electrical PILLAR
5°
2 Arakoon Crescent
'20"
1
52
IO
Drainage INSPECTION OUTLET Electrical SUBSTATION EDGE Sunshine Beach, Qld , 4567
'20
29.552
191°09
Drainage OPEN DRAIN Fence GATE
A
0
"
Electrical AIRCON Fence LINE DESCRIPTION
DE
Electrical LIGHT INGROUND C (QL-D) Located COMMUNICATIONS D
EL Electrical MARKER E (QL-D) Located ELECTRICAL D
Contour & Detail
S (QL-D) Located SEWER D W (QL-D) Located WATER D Pre Construction Surface
Park GARDEN EDGE Park FOLIAGE EDGE
Road LINE MARKING UNMAPPED Park TREE PROJECT DATUM
Surface RETAINING WALL TOP Road CROWN Horizontal Datum : MGA2020 z56 (Ground)
Surface SPOT LEVEL Road DRIVEWAY Vide PSM: 44262
Survey Marks STATION Road KERB BACK CONTROL COORDINATES - (MGA2020 - Ground) Level Datum : AHD D Vide PSM: 44262
Traffic SIGN Road KERB INVERT
STN EASTING NORTHING HEIGHT DESCRIPTION RL: 50.932
Water HYDRANT Road KERB LIP
Water METER Road KERB TOP PSM44262 510895.430 7079703.999 50.932 Standard
31
3°
04
717 Local Authority : Noosa Shire
14
Water PIT
CP
Sewer MANHOLE LID MSS001 511244.328 7079770.457 25.235 Screw in Kerb .12 '20
" RP48111 DRAWING INFORMATION
UN
Water UNKNOWN Surface BANK TOP MSS002 511255.911 7079722.521 21.904 Spike in Rock 0
Surveyed : CB Project No : M4371
boundary CORNER
boundary ROAD RESERVE
SP148682
Surface CHANGE OF GRADE
Surface CONCRETE
MSS003 511236.088 7079794.834 27.008 Nail in Kerb Drawn : CB Ref No : 3000-DS-2
MSS004 511226.130 7079812.178 28.572 Screw in Kerb Checked : MAW Date of Survey : 20/05/22
Australia Post POST BOX Surface PAVERS
CONTOURS
Building COLUMN Surface RETAINING WALL BOTTOM MSS005 511246.648 7079807.971 26.290 Screw in Concrete
Major : 1.00m Scale @ A3 : 1 : 250
Building DECK Water TAP MSS006 511267.567 7079803.708 24.920 Nail in Other Minor : 0.20m Date: 25/05/22
Building DOOR Water VALVE
MSS007 684
511266.215 7079791.146 24.573 Nail in Other
FL
Building FLOOR LEVEL boundary ADJACENT DRAWING NUMBER
Building GUTTER boundary LOT
MSS008 RP48111
511263.269 7079782.841 24.593 Nail in Other
Building LINE contours MAJOR MSS009 511262.147 7079779.535 24.621 Nail in Other M4371 3000 001
Building ROOFLINE contours MINOR MSS010 511254.575 7079785.706 24.842 Nail in Other Sheet No. 2 of 2 Revision : A