Effluent Disposal Area
Matter Raised Response
It must be demonstrated that each lot has An effluent disposal report has been provided as
sufficient area and other attributes to ensure part of Appendix G – Geotechnical Report which
efficient and effective on-site sewerage disposal. outlines the requirements for on-site effluent
disposal. The sites are capable of complying with
the recommendations from this report and a
development approval can be conditioned to
ensure compliance.
Biodiversity, Waterways and Wetlands Overlay
Matter Raised Response
The proposed house site areas and property The development proposes building envelopes
boundaries must be sited within existing cleared and lot boundaries in existing cleared areas and
areas or areas of low ecological value. areas of low ecological value. Refer to Appendix
E – Ecological Assessment Report for full details.
Bushfire Hazard Overlay
Matter Raised Response
Parts of the site are mapped Medium Potential A site specific bushfire hazard report has been
Bushfire Intensity and the building envelope of provided as part of this application. Refer to
proposed lot 2 is located within this level of Appendix F – Bushfire Hazard Assessment &
identified hazard area. A site-specific bushfire Management Plan.
hazard assessment report and management plan
would be required in accordance with PSP8
Natural Hazards.
Landslide Hazard Overlay
Matter Raised Response
The predominant area of the site and the A site-specific geotechnical report has been
proposed access is mapped landslide hazard provided as part of the development application
area. The Reconfiguring a Lot Code seeks (refer to Appendix G – Geotechnical Report). The
development ideally not to be located on land report has identified that there would be a low risk
identified as a landslide hazard. Any of slope instability impacting the proposed
development proposed on land identified as a development and that the development should
landslide hazard would need to be supported by be undertaken in accordance with
a site-specific geotechnical assessment recommendations contained within the report. A
prepared by a registered professional engineer, development approval can be conditioned to
in accordance with PSP8 Natural Hazards. The ensure compliance with the geotechnical
Landslide Hazard Overlay Code seeks buildings recommendations.
and associated accesses not to be constructed
on land with a slope greater than 25%.
The Landslide Hazard Overlay Code seeks The development will retain the existing house on
development to: be responsive to the natural Lot 1. A building envelope is proposed within Lot
topography and constraints imposed by the 2 for a future dwelling house which is situated at
slope; retain natural landforms, landscape a lower elevation than the existing house and will
character, vegetation and visual amenity of hill be located forward of the dwelling house on the
slops and ridgelines; visually integrate into the neighbouring lot to the north. Given the location
CadCon provides boundary, contour & detail and construction surveys, town planning applications, liaison & negotiation with Councils & Government,
coordination and liaison with architects, engineers etc, coordination and management of development projects from start to finish.