Change to exisiting approval - Plan 2 - OPW15 0099.01
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn
LEG
END
BULK EARTHWORKS SURFACE
FINISHED SURFACE
NATURAL SURFACE
ee
REDIRECT EXISTING OVERLAND
FLOW PATH INTO DETENTION BASIN
1 IN 3 BATTER MAX.
MAX 1.5m BOULDER RETAINING WALL
REFER ELEVATION ON DRG. 126
CLUBHOUSE
4.50m MAX-
EARTHWORKS NOTES
BULK
1.
FILE: 15-001261-1 i!
Xref's: X_15-001261_1
NOTWITHSTANDING THE LIMITS OF CUTTING AND FILLING
SHOWN ON THE CROSS SECTIONS, THE ACTUAL LIMITS
SHALL BE DETERMINED ON-SITE BY THE
SUPERINTENDENT DURING CONSTRUCTION AND SIMILARLY
THE FINISHED SURFACE CONTOURS MAY BE ADJUSTED
BY WRITTEN DIRECTION OF THE SUPERINTENDENT
DURING CONSTRUCTION.
SOAKED CBR TEST RESULTS FROM ROAD PAVEMENT
SUBGRADE SHALL BE FORWARDED TO THE
SUPERINTENDENT FOR DETERMINATION OF BOX DEPTHS
PRIOR TO EXCAVATION BEYOND THE ‘NOMINAL’ DEPTH.
CONTRACTOR TO LIAISE WITH ALL RELEVANT SERVICE
AUTHORITIES TO ASCERTAIN SERVICES PRESENT
ON-SITE. ANY ALTERATION WORKS TO SERVICES WILL
BE CARRIED OUT BY THAT SERVICE AUTHORITY ONLY.
THE CONTRACTOR SHALL NOTIFY THE SUPERINTENDENT
PRIOR TO COMMENCING THE DEMOLITION OF ANY
EXISTING STRUCTURES WITHIN THE SITE AREA.
ALL DRAINAGE STRUCTURES TO BE PRESERVED FROM
THE EFFECTS OF STRUCTURAL LOADING GENERATED BY
THE EARTHWORKS.
ALL EXCAVATION AND FILLING SHALL BE COMPACTED
TO THE REQUIREMENTS OF AS3798-1996 IN ACCORDANCE
WITH THE LOCAL AUTHORITY REQUIREMENTS. LEVEL 1
SUPERVISION IS REQUIRED.
ALL CLEARING SHALL BE CARRIED OUT IN STAGES TO
ALLOW FOR RELOCATION OF FAUNA, COMMENCING AT
THE LOWER AREAS OF THE SITE.
ALL CONSTRUCTION ACTIVITIES SHALL COMPLY WITH
WORKPLACE HEALTH AND SAFETY REQUIREMENTS.
ALL EARTHWORKS TO BE CONSTRUCTED IN ACCORDANCE
WITH PALNNING SCHEME POLICY PSPOS ENGINEERING
DESIGN STANDARDS.
DATE: 15-12-2015 TIME: 1655
ITLE USR: adam young
4
1% MINOR REGARDING AS REQUIRED
TO ENSURE SURFACE IS FREE
DRAINING TO OVERLAND FLOW PATH.
TURF BATTERS TO RETAIN
CLEAN WATER DIVERSION
SITE 102
ROAD 8
PB
POOL AREA SITE 68
1 IN 3 BATTER TO N.S.
LANDSCAPING CORRIDOR
WIDTH VARIES
NOTES:
1, RETAINING WALLS TO BE CONSTRUCTED
TO MANUFACTURERS SPECIFICATIONS. x
2. CONTRACTOR TO PROVIDE STRUCTURAL
CERTIFICATION FOR RETAINING WALLS.
DESIGN AND CONSTRUCTION.
3. PROVIDE APPROVED SAFETY FENCE TO
ALL WALLS HIGHER THAN 1.0m. .
4, ALL RETAINING WALL FOOTINGS TO BE RY
WHERE INDICATED IN FRONT OF WALL
TEMPORARY APPROVED
SAFETY FENCE TO WALLS
HIGHER THAN 1.00m |
PROPERTY BOUNDARY POSITION
PROPERTY BOUNDARY POSITION
JQVHERE INDICATED BEHIND WALL
iy
iS
5
LOCATED A MINIMUM 1.0m HORIZONTALLY 1
CLEAR OF THE ROOFWATER AND SEWER
fetuener tN BELOW THE ZONE OF PERMEABLE |
- GEOTEXTILE 1
MEMBRANE
MINIMUM DESIGN REQUIREMENTS
- SURCHARGE LOADING ON BACKFILL : SKPa
- POST AND FOOTING DESIGN TO ALLOW
FOR 1.8m HIGH FENCE
- MAX 1V:46H SLOPE BEHIND WALL
200mm WIDE
GRANULAR FREE
DRAINING MATERIAL:
HEIGHT USED FOR PAYMENT
1 IN 4 TURFED BATTER FOR MIN.
0.25m HIGH FOR REDIRECTION OF +
FLOW ALONG SITE BOUNDARY
F.S.L.
SECTION
SCALE (AN): 1.700
SCALE (A3):1:200
ACOUSTIC FENCE BY OTHERS.
REFER SOUND ENGINEERS PLANS
FOR HEIGHT AND DETAILS
tT]
2
SITE BDY
2.50m
LANDSCAPE BUFFER
NOTE
REFER DRG. 15-001261-401 FOR BASIN
RETAINING WALL DETAILS.
CONCRETE SLEEPER
RETAINING WALL BY OTHERS.
NO ALLOWANCE FOR
ACOUSTIC FENCE DESIGN.
SECTION
SCALE (AN): 1:100
SCALE (A3):1:200
A
RETAINING WALL DESIGN AND CONSTRUCTION TO BE RPEQ
CERTIFIED BY THE CONTRACTOR'S NOMINATED GEOTECHNICAL
ENGINEER. ROCKS TO BE PLACED IN STRETCHER BOND
PATTERN (MINIMUM VOID ALLOWABLE SHALL NOT BE
GREATER THAN 50mm IN ANY DIRECTION, WITH NO SPALLS
SMALLER THAN 750mm IN SIZE - i.e. NO VOID INFILLING)
TEMPORARY APPROVED
SAFETY FENCE TO WALLS
HIGHER THAN 1.00m
x
WHERE INDICATED BEHIND WALL
AN
GEOFABRIC TO
FACE OF WALL
PROPERTY BOUNDARY POSITION
NOTE:
BOULDERS TO BE ‘RANDOM’ GRADE SANDSTONE
(TRENCHED ROCK) RECTANGULAR IN SHAPE.
MINIMUM DESIGN REQUIREMENTS:
- SURCHARGE LOADING ON BACKFILL: SKPa
- ALLOW FOR 1.8m HIGH FENCE
100% SLOTTED SUBSOIL DRAIN Z
WITH FILTER SOCK. DISCHARGE
TO STORMWATER SYSTEM
STEEL UNIVERSAL COLUMNS—— |
TYPICAL CONCRETE SLEEPER RETAINING WALL DETAIL
SCALE 1: 20 {A1)
CONCRETE SLEEPERS
PROPERTY BOUNDARY POSTION
WHERE INDICATED BEHIND WALL
- MAX 1V:4H SLOPE BEHIND WALL 12000
HEIGHT USED FOR PAYMENT
COMPACTED FREE-DRAINING
GRANULAR BACKFILL (APPROX.
40-75mm DIA. SPALLS)
SELECTED COMPACTED BACKFILL
TYPICAL ‘RANDOM’ GRADE
SANDSTONE TRENCHED ROCK WALL
SCALE 1:20 (A1)
SCALE 1:40 (A3)
REF NO. 132007.2398.02
Feat [oauce [oeawe] _ oaTe penian cneox SCALE (METRES) TACROFIOM Wo. LENT DRAWS TE
AMENDMENT DETAILS: SURVEYOR: ML_SURVEYS
a eT aC VRC HAH ERG TRE ARES St 38 Leybourne Street, Chelmer QLD 4068 PALM LAKE WORKS PTY LTD CONSULT AUSTRALA BULK EARTHWORKS
MTB Tay aT 3105.6 [NOTE apDeD - DP |wo 1 oo 1 2 3 4 5m Mob: 0412 | Mob: 0412 7h/\223 E: [email protected] | E: murray@misurveys. com.au oS NOTES, DETAILS AND
N +200 a3 i: A
BC] BF | BF | 16.08.16 | SECTION E AMENDED TO SHOWN CONCRETE SLEEPER RETAINING WALL DRAWE-CHEGK PROJECT No. Calibre Consulting (QLD) Pty Ltd oe SECTIONS
iE ¢ 15-001261 Pm a (seven ra ( AGEN HHA 850 aN PAM Gono i i ie 2 ras = —
lego simile
Sir _ FOR & ON BEHALF OF CALIBRE CONSULTING (QLD) PTY LTD STAGE 1A CONSULTING Daan Cats i Sx Sep ttn cont ‘Tedd 15-001261-125
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.