Town Planning Assessment Report · MCU24/0120
● Existing services code;
● Fire services for common private title code;
● Landscaping code;
● Sustainable building design code;
● Transport code;
● Water quality and drainage code;
● Waste management code;
● Bushfire hazard overlay code.
The proposal has been assessed against the Acceptable Outcomes and Performance Outcomes of the
above codes in Attachment A, and is considered compliant. Where the proposal does not comply
with an Acceptable Outcome, alternative solutions to satisfy the corresponding Performance Outcome
have been provided. Elements of the code which are not applicable to the subject site or proposed
development have been removed from the tables below. No planning scheme conflicts have been
identified in relation to this proposal.
5.3 MEDIUM DENSITY RESIDENTIAL ZONE CODE
A review of the Medium density residential zone code has been undertaken. Refer to attached code
assessment. The proposed development meets the purpose, overall outcomes and the relevant
acceptable outcomes of the code. The proposal complies with, can comply with or can be conditioned
to comply with all of the relevant code requirements with the exception of the acceptable outcomes
below:
Performance Outcome Acceptable Outcome Response
PO12 Buildings and structures AO12.1 Buildings and The proposal seeks the
are designed and sited to: structures meet the following following front setback
(a) provide a high level of minimum boundary setbacks: relaxations:
amenity to users of the (a) for frontages — 6 metres
subject site and adjoining (b) for side boundaries— ● Unit 2 includes a feature
premises, including entry landscape arbour
(i) 1.5 metres setback up and privacy wall
provision of visual and to 4.5 metres height;
acoustic privacy; exceeding 2m in height
(ii) 2 metres setback within the front setback;
(b) not unreasonably obstruct between 4.5 metres ● 5.587m to ground floor
views or cause overlooking and 7.5 metres and 5.062m to wall nib
of private open space or height; and (Unit 2);
habitable areas of ● 4.929m to upper floor
(iii) 2.5 metres where
adjoining premises; (Unit 2);
above 7.5 metres
(c) provide adequate distance height ● Roof setbacks ranging
from adjoining land uses; from 4.859m-5.33m (Unit
(c) for the rear boundary - 6
(d) preserve existing metres 2);
vegetation that will help ● Unit 2 awning
buffer development; encroachments;
AO12.2 The front 6 metres of
(e) allow for space and ● 5.5m to fire separation
the property is landscaped
landscaping to be provided wall to western road
open space, provided that
between buildings frontage;
uncovered visitor parking, or
including adequate area at ● 5.277m to corner of Unit
swimming pools protruding no
ground level for 2 garage.
more than 1 metre above the
landscaping with trees, ground level, can be as close
shrubs, outdoor living and The development site is a
as 2 metres from the front
utilities; corner site, with two road
boundary.
frontages. The proposal
(f) be consistent with the
12
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Town Planning Assessment Report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 5.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.