Original source · versioned page text
MCU16/0079 Town Planning Report
Town Planning Report
“Undefined Use”
Staged Extension & Refurbishment of Existing RSL Club
5 Memorial Ave, Tewantin QLD 4565
Lot 3 on T16319 and Lot 10 on SP273411
Table 14-8 For all Business Uses
Column 1 Column 2 Compliance
Specific Outcomes Probable solutions (if code assessable)
14.16 Effects of use
Electricity infrastructure S18.1 No solution provided Complies – The proposed development is not located within
O18 The development does not adversely impact on existing S19.1 Development for uses adjacent to or within 50m of an 50m of an existing electricity substation nor does it include
or future electricity supply infrastructure; existing electricity substation incorporates noise attenuation any buildings or structures which are proposed under
AND measures to mitigate noise impacts; electricity transmission lines or within an electricity easement.
O19 All uses and works maintain an adequate safe distance AND It is considered the proposed development does not
from electrical infrastructure including substations, overhead S19.2 Buildings and structures (including swimming pools, adversely impact on the existing or further electricity supply
powerlines, power poles and transformers. sheds, tennis courts and outbuildings) are not constructed infrastructure. During construction all works will be
under overhead electricity transmission lines, or within undertaken in a safe manner and at a safe distance from any
electricity easements. electricity infrastructure.
Noise No solution provided Complies – The proposed development is considered to
O20 Development is designed and sited to avoid noise minimise any potential noise disturbance through
emissions that unreasonably diminish the amenity of the area development design. An Acoustic Report has been completed
or surrounding uses. which illustrates that the proposed development will not
create any adverse noise impact. Council is directed to
Appendix F – Environmental Noise Impact Assessment
for further details.
Mechanical plant and equipment and storage areas S21.1 Mechanical plant and equipment are— Complies – The proposed development has been designed
O21 Mechanical plant and equipment (including air a) located more than 2m from any property boundary; to ensure all mechanical plan and equipment is stored and
conditioning equipment) and storage areas are designed and b) where located at ground level, screened by fencing 1.5m in located away from any street view or adjoining property. The
located to— height or dense vegetation of at least 1.5m in width proposed development ensures all equipment is located a
a) avoid adverse visual impacts when viewed from the street incorporating grouped trees and shrubs with maximum minimum of 2m from any property boundary. All equipment
and adjoining properties; and separation distance of 1m measured from the centre of the will be suitably screened from public view and will were
b) visually integrate with the building design. tree or scrub; and possible be integrated into the building line. Council is
c) are visually integrated into the line and plane of the directed to Appendix B – Architectural Plans for further
building and roof design and do not project beyond the height details.
or width of the building when viewed from the street and
adjoining properties;
AND
S21.2 For Industrial business and Retail business Type 3,
materials stored outside of a building do not exceed 4m in
height or half the height of the on-site buildings whichever is
July 2016 Page | 17