Original source · versioned page text
Attachment 2A - UNIT DRAWINGS
RACV NOOSA RESORT - ECO RESORT
ROYAL AUTOMOBILE CLUB OF VICTORIA
142 NOOSA DRIVE, NOOSA HEADS QLD 4567
D.A. ISSUE
Project Number
TOOWOOMBA BRISBANE MAROOCHYDORE
P. (07) 46 329 962 WWW.ASPECTAPM.NET
A.B.N 96071786948 BOAQ 4487 21-0910
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take up to a minute.
Full text of the other 10 pages
Page 2
IMPORTANT:
ALL DRAWINGS MUST BE READ IN CONJUNCTION WITH
THE GENERAL NOTES SHEET
AMENDMENT SCHEDULE
ISS DATE DESCRIPTION BY
A 20/06/22 CONSULTANTS REVIEW ZT
10m WIDE
FIRE BUFFER
MANAGED ZONE
STORE
UNIT 1 20 CARPARKS
100
00
LINE
NG
LDI
BUI
UNIT 8
UNIT 2
UNIT 7
UNIT 6
UNIT 3
UNIT 5
TOOWOOMBA | BRISBANE | MAROOCHYDORE
www.aspectapm.net
ABN 96 071 786 948 ACN 071 786 948
UNIT 4 BOAQ 4487
BUILDING DESIGNERS
ASSOCIATION
GENERAL NOTES
THIS PLAN HAS BEEN PREPARED IN ACCORDANCE WITH ALL
RELEVANT BUILDING CODES AND STANDARDS. NO AMENDMENTS
SHALL BE MADE WITHOUT THE APPROVAL FROM ASPECT AND/OR
RELEVANT LOCAL AUTHORITY.THESE DRAWINGS ARE SUPPLIED ON
THE CONDITION THAT, IN THE EVENT OF ERROR, ASPECTS' LIABILITY
IS LIMITED ONLY TO THE COST OF AMENDING THESE DRAWINGS.
C:\Users\z.thorp\Documents\Revit User Files\AP210910-S01_REVISED_z.thorp.rvt
CONTRACTORS ARE TO VERIFY ALL DIMENSIONS ON SITE BEFORE
COMMENCING ANY WORK OR PRODUCING SHOP DRAWINGS. THESE
DRAWINGS ARE PROTECTED BY THE LAWS OF COPYRIGHT AND MAY
NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN
PERMISSION OF ASPECT .
PROJECT
RACV NOOSA RESORT - ECO
RESORT
FOR
ROYAL AUTOMOBILE CLUB OF
VICTORIA
@
PROJECT ADDRESS
DRAWING TITLE
20/06/2022 2:38:22 PM
SITE PLAN
N DATE SCALE @ A1 DRAWN CHECKED
20/06/22 1 : 250 AS TB
DRAWING No. ISSUE
1:250
0 2 4 6 8 10 20 21-0910_ 10-01 A
Page 3
IMPORTANT:
ALL DRAWINGS MUST BE READ IN CONJUNCTION WITH
THE GENERAL NOTES SHEET
AMENDMENT SCHEDULE
ISS DATE DESCRIPTION BY
A 28/01/22 SITE LAYOUT ZT
B 19/04/22 REVISION A ZT
PROPERTY DESCRIPTION C 29/04/22 SITE REVIEW TB
Project Description Visitor Accommodation Units
Site Description Lot 3 on SP126 203
Local Authority Noosa Shire Council
Locality Noosa Heads
Site Area 5,453m² (0.5453ha)
Developable Area 4,054m² comprising 3,818.5m² plus
236m² under Infrastructure Agreement
Site Cover 1,062m2
19.47%
Total GFA 1,628m2
Plot Percenatge 29.85%
10m WIDE Plot Ratio 0.30:1
FIRE BUFFER
MANAGED ZONE LEGEND
Green Environmental management &
Conservation Zone Overlay
Orange Tourist Accomodation
STORE Zone Overlay
20 CARPARKS
UNIT 1
100
00
LINE
NG
LDI
BUI
UNIT 8
UNIT 2
UNIT 7
UNIT 6
UNIT 3
UNIT 5
TOOWOOMBA | BRISBANE | MOOLOOLABA
www.aspectapm.net
ABN 96 071 786 948 ACN 071 786 948
BOAQ 4487
UNIT 4
BUILDING DESIGNERS
ASSOCIATION
GENERAL NOTES
THIS PLAN HAS BEEN PREPARED IN ACCORDANCE WITH ALL
RELEVANT BUILDING CODES AND STANDARDS. NO AMENDMENTS
SHALL BE MADE WITHOUT THE APPROVAL FROM ASPECT AND/OR
RELEVANT LOCAL AUTHORITY.THESE DRAWINGS ARE SUPPLIED ON
THE CONDITION THAT, IN THE EVENT OF ERROR, ASPECTS' LIABILITY
IS LIMITED ONLY TO THE COST OF AMENDING THESE DRAWINGS.
C:\Users\z.thorp\Documents\Revit User Files\AP210910-S01_REVISED_z.thorp.rvt
CONTRACTORS ARE TO VERIFY ALL DIMENSIONS ON SITE BEFORE
COMMENCING ANY WORK OR PRODUCING SHOP DRAWINGS. THESE
DRAWINGS ARE PROTECTED BY THE LAWS OF COPYRIGHT AND MAY
NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN
PERMISSION OF ASPECT .
PROJECT
RACV NOOSA RESORT - ECO
RESORT
FOR
ROYAL AUTOMOBILE CLUB OF
VICTORIA
CONCEPT DESIGN
@
142 NOOSA DRIVE, NOOSA HEADS
QLD 4567
DRAWING TITLE
27/06/2022 3:41:27 PM
ZONING SITE PLAN
N DATE SCALE @ A1 DRAWN CHECKED
29/04/22 1 : 250 AS TB
DRAWING No. ISSUE
1:250
0 2 4 6 8 10 20 21-0910_ A10-02 C
Page 4
IMPORTANT:
ALL DRAWINGS MUST BE READ IN CONJUNCTION WITH
THE GENERAL NOTES SHEET
AMENDMENT SCHEDULE
ISS DATE DESCRIPTION BY
A 27/05/22 CONSULTANTS REVIEW ZT
20 CARPARKS
STORE
RL 3.200
52 0
0
RL 3.200 15 0
0
UNIT 1
63
00
RL 4.000
UNIT 8
RL 3.200
PROPOSED PAD RL 3.400
RL 3.200
63
RL 4.000
00
UNIT 2
12
00
RL 4.000
52
UNIT 7
00
RL 4.000
4600
1500
RL 4.600
UNIT 6
3800
PROPOSED PAD RL 4.000
RL 4.000
RL 4.600
UNIT 3
UNIT 5
RL 4.600
RL 4.600 TOOWOOMBA | BRISBANE | MOOLOOLABA
www.aspectapm.net
ABN 96 071 786 948 ACN 071 786 948
UNIT 4
BOAQ 4487
BUILDING DESIGNERS
ASSOCIATION
GENERAL NOTES
THIS PLAN HAS BEEN PREPARED IN ACCORDANCE WITH ALL
RELEVANT BUILDING CODES AND STANDARDS. NO AMENDMENTS
SHALL BE MADE WITHOUT THE APPROVAL FROM ASPECT AND/OR
RELEVANT LOCAL AUTHORITY.THESE DRAWINGS ARE SUPPLIED ON
THE CONDITION THAT, IN THE EVENT OF ERROR, ASPECTS' LIABILITY
IS LIMITED ONLY TO THE COST OF AMENDING THESE DRAWINGS.
C:\Users\z.thorp\Documents\Revit User Files\AP210910-S01_REVISED_z.thorp.rvt
CONTRACTORS ARE TO VERIFY ALL DIMENSIONS ON SITE BEFORE
COMMENCING ANY WORK OR PRODUCING SHOP DRAWINGS. THESE
DRAWINGS ARE PROTECTED BY THE LAWS OF COPYRIGHT AND MAY
NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN
PERMISSION OF ASPECT .
PROJECT
RACV NOOSA RESORT - ECO
RESORT
FOR
ROYAL AUTOMOBILE CLUB OF
VICTORIA
CONCEPT DESIGN
@
PROJECT ADDRESS
DRAWING TITLE
20/06/2022 9:16:19 AM
SITE PLAN - CONTOURS
N DATE SCALE @ A1 DRAWN CHECKED
27/05/22 1 : 250 AS TB
DRAWING No. ISSUE
1:250
0 2 4 6 8 10 20 21-0910_ A10-10 A
Page 5
IMPORTANT:
ALL DRAWINGS MUST BE READ IN CONJUNCTION WITH
THE GENERAL NOTES SHEET
AMENDMENT SCHEDULE
ISS DATE DESCRIPTION BY
A 16/05/22 SITE SECTIONS ISSUE ZT
B 27/05/22 CONSULTANTS REVIEW ZT
C 20/06/22 CONSULTANTS REVIEW ZT
10m WIDE 10m WIDE
APZ - OUTER ZONE APZ - INNER ZONE
8m HEIGHT LIMIT
UNIT 8
2500
2500
UNIT 1 LV 1 WALKWAY
LV 1 CARPARK
3000
RL 3.200
RL 3.200
2900
GROUND
GROUND
EXISTING GROUND LINE
NEW STONE RETAINING WALL
SITE SECTION A
1
1 : 200
4000 6000
BOUNDARY
BOUNDARY
FIRE BUFFER SETBACK
BUILDING SETBACK
8m HEIGHT LIMIT
UNIT 6
2500
LV 1
UNIT 2 CARPARK
(BEYOND) WALKWAY
3000
WALKWAY
GROUND
NEW STONE RETAINING WALL
SITE SECTION B
2
1 : 200
TOOWOOMBA | BRISBANE | MOOLOOLABA
www.aspectapm.net
6000
ABN 96 071 786 948 ACN 071 786 948
BOAQ 4487
BOUNDARY
FIRE BUFFER SETBACK
BUILDING DESIGNERS
ASSOCIATION
GENERAL NOTES
THIS PLAN HAS BEEN PREPARED IN ACCORDANCE WITH ALL
RELEVANT BUILDING CODES AND STANDARDS. NO AMENDMENTS
SHALL BE MADE WITHOUT THE APPROVAL FROM ASPECT AND/OR
8m HEIGHT LIMIT RELEVANT LOCAL AUTHORITY.THESE DRAWINGS ARE SUPPLIED ON
THE CONDITION THAT, IN THE EVENT OF ERROR, ASPECTS' LIABILITY
IS LIMITED ONLY TO THE COST OF AMENDING THESE DRAWINGS.
C:\Users\z.thorp\Documents\Revit User Files\AP210910-S01_REVISED_z.thorp.rvt
CONTRACTORS ARE TO VERIFY ALL DIMENSIONS ON SITE BEFORE
COMMENCING ANY WORK OR PRODUCING SHOP DRAWINGS. THESE
2500
DRAWINGS ARE PROTECTED BY THE LAWS OF COPYRIGHT AND MAY
UNIT 2 UNIT 1 NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN
LV 1 PERMISSION OF ASPECT .
CARPARK PROJECT
RACV NOOSA RESORT - ECO
RL 3.200
3000
GROUND RESORT
FOR
ROYAL AUTOMOBILE CLUB OF
VICTORIA
CONCEPT DESIGN
@
PROJECT ADDRESS
DRAWING TITLE
SITE SECTION C
24/06/2022 10:18:03 AM
3 SITE SECTIONS
1 : 200 DATE SCALE @ A1 DRAWN CHECKED
20/06/22 1 : 200 AS TB
DRAWING No. ISSUE
1:200
0 2 4 6 8 10 20m 21-0910_ A50-01 C
Page 6
C:\Users\z.thorp\Documents\Revit User Files\AP210910-S01_REVISED_z.thorp.rvt 21/06/2022 12:02:12 PM 2500 3000 und Floor, a CABIN SECTION 01 —* 4:100 Boardwalk 2500 3000 (Cc) \o) 4600 DINING oy CABIN SECTION 02 “/ 4:100 Roof 2500 | DINING BED 1 TH — a l __—_ Level 1 3000 , DINING 1 BED 1 a 3) DUPLEX CABIN SECTION 01 —* 4:100 Ground Floor- A M4 R 3) ww Level 1 Ground Floor (3) Cee 3) ee © ! 2560 ! 1800 2405, | ] b | 3000 A DUPLEX CABIN SECTION 02 4: 100 = oa So oO oO = i) wo aN oa = Oo Level 1 Ground Floor IMPORTANT: ALL DRAWINGS MUST BE READ IN CONJUNCTION WITH THE GENERAL NOTES SHEET AMENDMENT SCHEDULE ISS. DATE DESCRIPTION BY A 27/05/22 CONSULTANTS REVIEW B 20/06/22 CONSULTANTS REVIEW NN INASPECT TOOWOOMBA | BRISBANE | MOOLOOLABA www.aspectapm.net ABN 96 071 786 948 ACN 071 786 948 BOAQ 4487 BUILDING DESIGNERS "ASSOCIATION a 0 GENERAL NOTES THIS PLAN HAS BEEN PREPARED IN ACCORDANCE WITH ALL. RELEVANT BUILDING CODES AND STANDARDS. NO AMENDMENTS. SHALL BE MADE WITHOUT THE APPROVAL FROM ASPECT AND/OR RELEVANT LOCAL AUTHORITY.THESE DRAWINGS ARE SUPPLIED ON THE CONDITION THAT, IN THE EVENT OF ERROR, ASPECTS' LIABILITY IS LIMITED ONLY TO THE COST OF AMENDING THESE DRAWINGS. CONTRACTORS ARE TO VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PRODUCING SHOP DRAWINGS. THESE DRAWINGS ARE PROTECTED BY THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN PERMISSION OF ASPECT . PROJECT RACV NOOSA RESORT - ECO RESORT CONCEPT DESIGN FOR ROYAL AUTOMOBILE CLUB OF VICTORIA @ PROJECT ADDRESS DRAWING TITLE TYPICAL CABIN SECTIONS DATE SCALE @A1 DRAWN CHECKED 20/06/22 1: 100 AS TB DRAWING No. ISSUE 21-0910_ A50-02 B
Page 7
IMPORTANT:
ALL DRAWINGS MUST BE READ IN CONJUNCTION WITH
THE GENERAL NOTES SHEET
AMENDMENT SCHEDULE
ISS DATE DESCRIPTION BY
A 20/06/22 CONSULTANTS REVIEW ZT
VIEW 01
UNIT 3
TOOWOOMBA | BRISBANE | MOOLOOLABA
www.aspectapm.net
ABN 96 071 786 948 ACN 071 786 948
BOAQ 4487
BUILDING DESIGNERS
ASSOCIATION
GENERAL NOTES
THIS PLAN HAS BEEN PREPARED IN ACCORDANCE WITH ALL
RELEVANT BUILDING CODES AND STANDARDS. NO AMENDMENTS
SHALL BE MADE WITHOUT THE APPROVAL FROM ASPECT AND/OR
RELEVANT LOCAL AUTHORITY.THESE DRAWINGS ARE SUPPLIED ON
THE CONDITION THAT, IN THE EVENT OF ERROR, ASPECTS' LIABILITY
IS LIMITED ONLY TO THE COST OF AMENDING THESE DRAWINGS.
C:\Users\z.thorp\Documents\Revit User Files\AP210910-S01_REVISED_z.thorp.rvt
CONTRACTORS ARE TO VERIFY ALL DIMENSIONS ON SITE BEFORE
COMMENCING ANY WORK OR PRODUCING SHOP DRAWINGS. THESE
DRAWINGS ARE PROTECTED BY THE LAWS OF COPYRIGHT AND MAY
NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN
PERMISSION OF ASPECT .
PROJECT
RACV NOOSA RESORT - ECO
VIEW 02 RESORT
UNIT 3 FOR
ROYAL AUTOMOBILE CLUB OF
VICTORIA
CONCEPT DESIGN
@
PROJECT ADDRESS
DRAWING TITLE
20/06/2022 4:06:25 PM
PERSPECTIVES
DATE SCALE @ A1 DRAWN CHECKED
20/06/22 AS TB
DRAWING No. ISSUE
21-0910_ A90-01 A
Page 8
IMPORTANT:
ALL DRAWINGS MUST BE READ IN CONJUNCTION WITH
THE GENERAL NOTES SHEET
AMENDMENT SCHEDULE
ISS DATE DESCRIPTION BY
A 20/06/22 CONSULTANTS REVIEW ZT
VIEW 01
UNITS 7 & 8
TOOWOOMBA | BRISBANE | MOOLOOLABA
www.aspectapm.net
ABN 96 071 786 948 ACN 071 786 948
BOAQ 4487
BUILDING DESIGNERS
ASSOCIATION
GENERAL NOTES
THIS PLAN HAS BEEN PREPARED IN ACCORDANCE WITH ALL
RELEVANT BUILDING CODES AND STANDARDS. NO AMENDMENTS
SHALL BE MADE WITHOUT THE APPROVAL FROM ASPECT AND/OR
RELEVANT LOCAL AUTHORITY.THESE DRAWINGS ARE SUPPLIED ON
THE CONDITION THAT, IN THE EVENT OF ERROR, ASPECTS' LIABILITY
IS LIMITED ONLY TO THE COST OF AMENDING THESE DRAWINGS.
C:\Users\z.thorp\Documents\Revit User Files\AP210910-S01_REVISED_z.thorp.rvt
CONTRACTORS ARE TO VERIFY ALL DIMENSIONS ON SITE BEFORE
COMMENCING ANY WORK OR PRODUCING SHOP DRAWINGS. THESE
DRAWINGS ARE PROTECTED BY THE LAWS OF COPYRIGHT AND MAY
NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN
PERMISSION OF ASPECT .
PROJECT
RACV NOOSA RESORT - ECO
VIEW 02 RESORT
UNITS 6 (LEFT), 4 (FAR BACK) & 3 (RIGHT) FOR
ROYAL AUTOMOBILE CLUB OF
VICTORIA
CONCEPT DESIGN
@
PROJECT ADDRESS
DRAWING TITLE
20/06/2022 4:06:37 PM
PERSEPCTIVES
DATE SCALE @ A1 DRAWN CHECKED
20/06/22 AS TB
DRAWING No. ISSUE
21-0910_ A90-02 A
Page 9
(3) wv, (eo) (8) (D) 22800 ®) Ns (o) NU? 3400 4600 3400 3400 4600 3400 LS 12560 3600 DECK 01 a |) BED4 \ 4600 1 i Sem || LOUNGE —_* AA ( DINING =" KITCHEN — DECK 02 = = DECK 02 a a [__| LOUNGE DINING 7 BED 2 BED 2 N ENTRY | 3 |sKITCHEN EA te 2560 1800 ~ ENSUITE O @ | UNIT5&6 CONCEPT DESIGN ISSUE IMPORTANT: ALL DRAWINGS MUST BE READ IN CONJUNCTION WITH THE GENERAL NOTES ON SHEET: A.00 No| Date | Amendment A 21/01/22 CONCEPT B 25/03/22 REVISION C 27/05/22 CONSULTANTS REVIEW D 20/06/22 CLIENT REVIEW GENERAL NOTES THIS PLAN RELEVANT DRAWINGS, AMENDMENTS SHALL BE MADE WITHOUT THE APPROVAL FROM ASPECT ANDIOR RELEVANT LOCAL AUTHORITY. THESE HAS BEEN PREPARED IN ACCORDANCE WITH ALL BUILDING CODES AND STANDARDS. NO BUILDING, ‘ARE SUPPLIED ON THE CONDITION THAT, IN THE EVENT OF ERROR, ASPECTS’ LIABILITY IS LIMITED ONLY TO THE COST OF AMENDING THESE DRAWINGS. ‘CONTRACT ORS ARE TO VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR PRODUCING SHOP. DRAWINGS, THESE DRAWINGS ARE PROTECTED BY THE LAWS. OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN PERMISSION OF ASPECT ALL DRAINAGE TO BE IN ACCORDANCE WITH LOCAL COUNCIL REQUIREMENTS AND APPROVED PLANS. ASPECT DESIGN STUDIOS IS NOT RESPONSIBLE FOR THE STRUCTURAL DESIGN OF THIS ga Ss BUILDING DESIGNERS ea "ASSOCIATION ASPECT TOOWOOMBA BRISBANE P. (07) 46 329 962 www.aspectapm.net A.B.N 96071786948 BOAQ 4487 RACV ECO CABIN RESORT NOOSA RACV Designer ~ | Sheet Name DUPLEX - FLOOR PLAN 01 Drawn by ~ | Sheet Number Gheckedby Checker A21-01 Client Signature / / Plot Date 20/06/22 Project Number 210910 | Scale 1:100 A3
Page 10
(pn) (By (c) (Dd) (E) (F) (6)
Ce (8) i) O (Ee) FD) \S)
| 22800 | |
T T T T T
3400 ; 4600 3400 3400 4600 3400
a fff
b
WY =
8
8 | | LOUNGE |_| 2
8 DECK 01 an a
| }—__F —— ; J bl
> DECK 02 —L —
(> \ :
Se ; 1 ed y = FA 7 = - a I | |
| BED 1 \ [| DINING jj LOUNGE r
. . i DECK 01
‘ef te! 7 BED 2 :
So =|
g| & DECK 02
R _
= ODO ENTRY FAA
|_| r-—4 (| DINING |}
(3\— = = ] INTCHEN | _ a - = = =)
Ye \ ee / |
° tre ENSUITE L/L _ |
gs —
n ye | | ENTRY
t | —— AL a
~ mi —-h | a 7 KITCHEN
= [
\4 J ~ ~ — = — ria — YT — _
2 ; Kt 4++UP a es
8 | ITT] ENSUITE =
= | H QO y
~ @ | —
( 5 } a + a a + a a a SS —————— = = =
WY
\
XY 8
a
—| rir ded &
| | ENSUITE |
| | co |
U N IT 7 & 8 \ \ \ ee \ \ >
IMPORTANT: ALL DRAWINGS MUST BE READ IN CONJUNCTION WITH THE GENERAL NOTES ON SHEET: A.00
No| Date | Amendment GENERAL NOTES RACV Designer - | Sheet Name DUPLEX - FLOOR PLAN
| ESgrtiaserrermescoprgg ns | a cs
A 2101/22 CONCEPT AMENDMENTS SHALL BE MADE WITHOUT mebROVAL | SAGERERPONSILE SOR SE SiRCN TUR DESC OE ES TOOWOOMBA Drawn by ~ | Sheet Number
FROM ASPECT AND/OR RELEVANT LOCAL AUTHORITY. THESE | BUILDING. BRISBANE a A21 01
B 25/03/22, REVISION EVENT OF ERROR, ASPECTS UAB SLUMTEDOMY TO | P. (07) 46 329 962 Checked by Checker .
C 27/05/22 CONSULTANTS REVIEW ‘THE COST OF AMENDING THESE DRAWINGS. ga www.aspectapm.net | ECO CABIN RESORT
D 20/06/22 CLIENT REVIEW re ; eS niSer feasts Client Signature /_/__| PlotDate 20/06/22
DRAWINGS THESE DRAWINGS ARE PROTECTED BY THE LAWS i, Boag 4487 | NOOSA RACV /
WITHOUT THE WRITTEN PERMISSIONOF ASPECT. ae ee Project Number 210910 mscae 1:100 A3
Page 11
UNITS 2-4 |
UNIT 1 MIRROR REVERSE
| 11400 y
L 3400 4600 L 3400
2505
(4)\—- + = ee -
r
8 | dl
8 DECK
1
LOUNGE SOFA BED
— |
@-- +, -
] AA
s [| DINING J]
5
= 2°
3
t+
(a
SZ
S N
g
-
(4\)—-—+- - —
(ej-L BL _
2
AREAS
UNIT GFA
DECK
97m?
9m2
CONCEPT DESIGN ISSUE
IMPORTANT: ALL DRAWINGS MUST BE READ IN CONJUNCTION WITH THE GENERAL NOTES ON SHEET: A.00
No |
Amendment
moon>
Date
21/01/22
28/01/22
25/03/22
27/05/22
20/06/22
CONCEPT
CONCPET V2
REVISION
CONSULTANTS REVIEW
CLIENT REVIEW
GENERAL NOTES
‘THIS PLAN HAS BEEN PREPARED IN ACCORDANCE WITH ALL
RELEVANT BUILDING CODES AND STANDARDS. NO
AMENDMENTS SHALL BE MADE WITHOUT THE APPROVAL
FROM ASPECT ANDIOR RELEVANT LOCAL AUTHORITY. THESE
DRAWINGS ARE SUPPLIED ON THE CONDITION THAT, IN THE
EVENT OF ERROR, ASPECTS’ LIABILITY IS LIMITED ONLY TO
THE COST OF AMENDING THESE DRAWINGS.
CONTRACTORS ARE TO VERIFY ALL DIMENSIONS ON SITE.
BEFORE COMMENCING ANY WORK OR PRODUCING SHOP.
DRAWINGS, THESE DRAWINGS ARE PROTECTED BY THE LAWS
OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED
WITHOUT THE WRITTEN PERMISSION OF ASPECT
ALL DRAINAGE TO BE IN ACCORDANCE WITH LOCAL COUNCIL
REQUIREMENTS AND APPROVED PLANS. ASPECT DESIGN STUDIOS
IS NOT RESPONSIBLE FOR THE STRUCTURAL DESIGN OF THIS
BUILDING,
A)
z BUILDING DESIGNERS. éa
"ASSOCIATION
ASPECT
TOOWOOMBA
BRISBANE
P. (07) 46 329 962
www.aspectapm.net
A.B.N 96071786948
BOAQ 4487
RACV Designer ~ | Sheet Name SINGLE UNIT - FLOOR PLAN LAYOUT
Drawn by ~ | Sheet Number
Checked by Checker A2 1 -01
ECO CABIN RESORT Client Signature Plot Date
NOOSA RACV / / 20/06/22
Project Number 21-0910 | Scale 1:100 A3