07/0567 - MCU - Multiple Housing Type 2 Duplex [As Published] · 132007.567
PROJECT DESCRIPTION
LOT NO.S 1 & 2 ON GTP 4S2 OR RP 81559
PARISH OF NOOSA
COUNTY OF MARCH
LOCAL AUTHORITY : NOOSA COUNCIL
TOTAL ALLOTMENT AREA : 613m Sq
CONSTRUCTION NOTES
ACCESS & EGRESS:
THRESHOLDS:
FIRE HAZARD PROPERTIES:
FIRE RATINGS:
GENERAL
SITE VERIFICATION
CONTROL JOINTS
WINDOWS
EXTERNAL FIXINGS AND
FITTINGS
PLUMBING AND
ACCESS PANELS
e@ HANDRAILS
CARPARKS
SECURITY
SMOKE DETECTION
& EXTINGUISHERS
DESIGN / DRAWN :
ROBERT PATTERSON
LL) QBSA Lic.No, 1095554
fax : (07) 5449 1899
DESIGN to DETAIL m : 0401 394 964
: [email protected]
PROVIDE A CONTINUOUS PATH OF TRAVEL TO AND WITHIN THE BUILDING TO PROVIDE ACCESS TO ALL
REQUIRED FACILITIES. ACCESSWAYS, WALKWAYS, RAMPS AND LANDINGS SHALL HAVE AN
UNOBSTRUCCTED WIDTH OF NOT LESS THAN 900mm AND BE CONSTRUCTED WITH MIN. LIP OR STEP AT
JOINTS BETWEEN ABUTTING SURFACES. ALL GRADIENTS AND CROSSFALLS SHALL NOT EXCEED 1:40.
ALL THRESHOLDS FOR DISABLED ACCESS MUST HAVE A MAXIMUM CONSTRUCTION STEP TOLERANCE
OF 5mm WHICH {S ACCEPTABLE USING ROUNDED OR BEVELLED E0GES, PROVIDE RECESSED SLIDING
DOOR FRAMES WHERE REQUIRED. - GENERALLY 20mm TO 100MM STEP AS SHOWN ON DRAWINGS
ALL MATERIALS AND ASSEMBLIES MUST COMPLY WITH SPECIFICATION C1:10 OF THE BCA FOR CLASS 2
BUILDINGS.
EXTERNAL LOADBEARING WALLS 90/60/30
EXTERNAL LOADBEARING POSTS / COLUMNS 90/-/-
INTERNAL LOADBEARING WALLS lef
INTERNAL LOADBEARING POSTS / COLUMNS 60/-/-
COMMON WALLS OR FIRE-WALLS 90/90/30
FLOORS 60/-/-
ROOF a-f-
ALL WORK TO COMPLY WITH BUILDING CODE OF AUSTRALIA AND ITS MOST CURRENT AMENDMENTS
THIS
CONSTRUCTION BEING MIXED CLASSES 2 OF TYPE B CONSTRUCTION
BEFORE COMMENCING CONSTRUCTION ALL DIMENSIONS, EXISTING LEVELS, FINISHED LEVELS AND
ALL SITE'SERVICES ARE TO BE VERIFIED ARCHITECTURAL DRAWINGS ARE TO BE READ IN
CONJUNCTION WITH ANY ASSOCIATED CONSULTANTS DRAWINGS
GENERALLY WHERE FLUSH FINISH IS REQUIRED BETWEEN TWO BUILDING ELEMENTS, PROVIDE A V-
TYPE CONTROL JOINT PROVIDE CONTROL JOINTS AT MAXIMUM 3 METRE CENTRES TO EXTERNAL TILED
AREAS SUCH AS BALCONIES, ENTRANCES, ETC REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR
CONSTRUCTION JOINTS. 6M CENTRES FOR EXTERNAL WALLS, OR AS PER ENGINEERS DESIGN.
WINDOW FRAME AND GLAZING TO BE INSTALLED TO THE CORRECT TERRAIN CATEGORY INCLUDING
LOCAL PRESSURE FACTORS IN ACCORDANCE WITH AS1288
TO BE NON-COMBUSTIBLE AND CORROSION-RESISTANT
ALL PLUMBING DUCTS TO HAVE ACCESS PANELS TO COUNCIL REQUIREMENTS
HANDRAILING AND BALUSTRADING TO COMPLY WITH PARTS 02.16 AND 02.17 OF BCA
ALL CARPARKS SHALL BE IN ACCORDANCE WITH THE AUSTRALIAN CARPARK STANDARDS AS 2890.1 -
4993 AND LOCAL COUNCIL REQUIREMENTS
SELECTED BY OWNER, UPON MANUFACTURERS RECOMMENDATIONS.
SMOKE DETECTORS SYSTEM TO AUSTRALIAN STANDARDS & BCA REQUIREMENTS LOCATEO BETWEEN
KITCHEN & BED RMS
FIGURED DIMENSIONS TO TAKE PRECEDENCE OVER
SCALED MEASUREMENTS, VERIFY ALL ON SITE
DIMENSIONS AND LEVELS PRIOR TO THE
COMMENCEMENT OF ANY CONSTRUCTION.
CONTRACTOR TO NOTIFY DESIGNER IMMEDIATELY
OF ANY DISCREPENCIES.
BUILDER :
KJ CONSTRUCTIONS
QBSA Lic.No. 21815
fax : (07) 5447 1714
m : 0409 471 714
€: [email protected]
K) CONSTRUCTIONS
CLIENT
PLANNING PERAMETERS
THIS PROJECT REQUIREMENTS :
SITE AREA:
CURRENT ZONING :
ASSESMENT :
OVERLAY Y/N:
QLD DEV. CODE
SUSTAINABILTY REQUIREMENTS :
WATER SAVINGS TARGETS :
IDEAS CHECKLIST SUPPLIED Y/N:
MAX BUILDING HEIGHT :
POPULATION DENSITY :
MAX PLOT RATIO (GROSS FLOOR AREA) :
MAX. SITE COVER
MIN, SOFT LANDSCAPING :
CAR PARKING :
FLOOD LEVEL & DRAINAGE :
THIS PROJECT :
Notes :
613m Sq
MULTIPLE HOUSING TYPE 2 DUPLEX
MCU APPLICATION : CODE ASSESABLE :
PART 14 DIV 1-12.
NO
YES
YES - TO QLD DEVELOPMENT CODE PART 29
YES - TO QLD DEVELOPMENT CODE PART 25
YES
8m MAX. 2 STOREY
2 BED PLUS 3 BED ALLOWANCE
0.45 :1 (45 %)
40% (245m)
20% (122.6m) NATIVE SPECIES.
41 OCCUPIER SPACE PLUS 1 VISITOR SPACE MIN,
RL 2.500
The site has an existing Duplex on it that is occupied by the owner in No.1. The owner
will build & occupy the new Duplex in No.1.
The old Duplex will be demolished & recycled appropriately.
The site will be filled & compacted with approved imported earth.
Footings will be designed to suit by an Engineer.
The Proposed GFA is well under the requirement, and is actually less than the existing
dwelling, but the Proposed Site Cover is a mere 1 % over the allowance.
2 visitor Car Parking Spaces will be provided.
A3 -point turn & forward gear can be used to enter & exit the proposed carparks &
Double lockup Garages from the street.
Also Refer Page 2 for further Notations
PROPOSED DUPLEX at
JOB DESCRIPTION
LOTS 1&2 AT 23 EDWARD ST,
NOOSAVILLE A
DESCRIPTION
THIS PROJECT PROVISIONS :
AREAS:
EXISTING :
LOT 1: 233.28 sqm
LOT 2: 235.97sqm
COMMON AREA: 143.86 sqm
LIVING : 177.6 sqm
GARAGE : 36.9 sqm
COURT: 25.9
TOTAL : 240.1 or 39% or Plot Ratio of 0,39:1
EXISTING GFA: 177.6 sqm or 29%
EXISTING SITE COVER : 221.5 sq mor 36 %
PROPOSED :
LOT 1: 246.20 sqm (40.2 % ea.)
LOT 2: 246.20 sqm
COMMON AREA: 120.70 sqm (19.6% )
GROUND FLOOR :
LIVING: 73 sqm
GARAGE : 47 sqm
OPEN ENTRY COURT : 12 sqm
(reduce to 7sqm after 600 o/hang for GFA)
TOTAL: 132sqm EA. (264sqm) or 43%
or 0.43:1 Plot Ratio
FIRST FLOOR:
LIVING: 110sqm
BALCONY : 40 sqm
TOTAL: 150 sqm
PROPOSED GFA: 85 sqm ea.: 170 sqm or 27 %
SITE COVER : 127sq m ea. ( 254. sqm) or 414%
LANDSCAPING :
PAVED : 66 sqm ea. (122 sq m) (incl. entry court)
EX. AGG DRIVE-WAY : 46 sqm ea. (92sq m)
SOFTSCAPE GARDEN BEDS : 61 sqm (122sq m) or 20 % .
POOL : 10.8 sqm ea. (21.6 sq m)
TOTAL : 178.8 ea. (357.6 sqm) or 58%
DEVELOPMENT
APPROVAL
{ NOT FOR CONSTRUCTION }
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/0567 - MCU - Multiple Housing Type 2 Duplex [As Published]Related documentApplication case desk ↗
About this file
- File size
- 2.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.