                                  VOID



     POOL
    BELOW
                                                  FALL
                                                                                                                                                 FALL


                                                                            SKYLIGHT




                                                                                          FALL                                SKYLIGHT

                                                                                          FLAT ROOF                           SKYLIGHT




                                                                            SKYLIGHT




   POOL                                           FALL
  BELOW                                                                                                                                          FALL




                                  VOID




                                               10230                                      7925                                           6870

                                               10230                                      7925

                                                                                                                                   600



                                                                                                                                                       700




                                                             2990


                                                                           2990




                                                                                                       2490

                                                                                                                     2490
                                VOID



                                                                                         FLAT ROOF
 POOL
BELOW

                                                  FALL                                                                                          FALL
                15370

                        15370




                                                                                                                                                             14870

                                                                                                                                                                     14870
                                                  FALL                                                                                          FALL

 POOL
                                                                                                                                                                             DRIVEWAY
BELOW
                                                                                         FLAT ROOF                                                                            BELOW


                                VOID
                                                          2490

                                                                    2490




                                                                                                              2490

                                                                                                                       2490
                                                                                                                                                       700


                                               10230                                      7925                                     600


                                               10230                                      7925                                           6870




                                                           BUILDING PERIMETER 90.75m

                                                           OF WHICH HAS EAVES 79.61m

                                                                                       =87.7%




                                                                                                                                                                                        CLIENT: Craig & Nathan Francis           PROJECT: REGENCY NOOSA
                                                                                                      GENERAL NOTES:
            www.chriscloutdesign.com.au                                                               Use written dimensions only. DO NOT scale drawings.                               SITE ADDRESS: LOT 2 & 3 MCH3881 128-132 Gympie Tce, NOOSAVILLE QLD 4566
            PO BOX 135, NOOSAVILLE, QLD                                                               Contractors to verify all dimensions on site prior to commencing
            4566
            E: [email protected]                                                           works. Site location in accordance with engineers details. These                  DRAWING TITLE:EAVES CALCULATION
            P: (07) 54748 107                                                                         drawings are to be read in conjunction with engineers design and
                                                                                                                                                                                        DATE: 07-09-23 SCALE: 1 : 100    @ A1 DRAWN BY:C.CLOUT
                                                                                                      details, the accompanying building specification and schedule of
            F: (07) 54748 108      BSA LICENCE: 1127508
                                                                                                      finishes. If in doubt, please request clarification. DO NOT                       ISSUE: PRELIMINARY CONCEPT
                                                                                                                                                                                                                                                      C8.0
                                                                                                      ASSUME.
Log in to download the original file

2ND LODGEMENT REPS design.pdf · 9.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.