               Noosa Shire Council Subordinate Local Law No. 1 (Administration) 2015          89


             (d)   public liability insurance in relation to the gate or grid is taken out and
                   maintained for an amount not less than $20,000,000 or such an amount as
                   determined by the local government and which also indemnifies the local
                   government in respect of any liability arising from the gate or grid; and
             (e)   a management program is in place, which details how and when the gate or
                   grid will be monitored and maintained.
    (3)   For approvals for installing or operating an electrified grid on a road, the conditions that
          will ordinarily be imposed are that the approval holder must ensure that –
             (a)   the energising unit conforms to international standards and is installed strictly
                   in accordance with the manufacturer’s requirements; and
             (b)   grid mats cover –
                   (i)    in the case of sealed roads – a minimum area of 6 metres by 1.8 metres;
                          and
                   (ii)   in the case of other roads – a minimum area of 3.6 metres by 1.8
                          metres; and
             (c)   grid mats are placed symmetrically about the centre line of the pavement unless
                   directed otherwise by the local government; and
             (d)   mats and mesh are installed in accordance with the manufacturer’s instructions;
                   and
             (e)   a sign on which the words “Caution – Electrified” are prominently and
                   permanently displayed is exhibited on a conspicuous part of the structure so
                   that it can be viewed by members of the public; and
             (f)   warning signs W8-1B (Red Triangle), W5-16B (Grid) and W8-Special B
                   (Caution electrified) are erected on both approaches so that –
                   (i) the warning signs are not less than 75 metres and not more than 225 metres
                          from the grid; and
                   (ii) the lateral placement of the warning signs is not less than 2 metres and not
                          more than 4 metres from the pavement edge; and
             (g)   a management program is maintained, which details how and when the grid
                   will be monitored and maintained.

7   Term of approval
    (1)   The term of an approval commences on the date the approval is granted and expires on
          the next 30th day of June, unless otherwise specified in the approval.
    (2)   An approval expires at the end of the day for expiry specified in subsection (1).

8   Term of renewal of approval

    The term of a renewal of the approval shall be the term stated in the renewal.
Log in to download the original file

2020-02-11 P&E Agenda - Item 4 - Attachment 2 - Subordinate Local Law No 1 (Administration) 2015(PDF, 2MB).pdf · 2.6 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.