Log in to see the plans as drawn BIN KEEP WITH MATCHING 38X16 ALUMINIUM PROFILE - 40MM GAPS
SCREEN / SURROUND
REAR WALL PAINTED
REFER TO FINISHES
1200 1200
INTERNAL LANDING LANDING EXTERNAL
2100
240 300
MIN
BD6 TO EXIT
240
1000 MAX
MAX
2700 2665 MAX 2665
1LEVEL1 1LEVEL1
1490
16
2700 15 2700
14
FIRE EXIT 13
TO
1000
MAX
12 ENGINEERS
11 DESIGN
10
9
8
BD5
240 7
6
FIRE ESCAPE ELEVATION
158
MAX 5
4 SCALE: 1 : 50 6
EQUAL RISERS TO SUIT LEVELS AND TO BE;
3
175 2 RISER: 190 MAX AND 115 MIN C71.1
1 GOING: 240 MAX AND 355 MIN
AHD 4
HANDRAIL EXTENSION
C71.1 1200 1200
0 320 240 300 240
LANDING LANDING
300 MIN 1 TREAD
BD5
1 2 3 4 5 6 7 8 8 10 11 12 13 14 15 16 5 4 3 2 1
BD6
BASEMENT FIRE EXIT STAIR - SECTION 175
UP
2665
1750
SCALE: 1 : 50 1 UP
C71.1
LEVEL 1
1
SIDE SETBACKS – EQUAL OR
C71.1
LESS TO HALF THE WALL HEIGHT
BASEMENT FIRE EXIT STAIR - PLAN
1740 SCALE: 1 : 50
STAIR AND TACTILE SECTION
BOUNDARY
340 TOTAL 240
300 MIN ONE TREAD EXTENSION
FIRE
ESCAPE
STAIR
60
GAP
HANDRAIL
40
1000 MIN CLEAR WIDTH
TOP LANDING
PATHWAY
1970
60 40
HANDRAIL
GAP
FIRE ESCAPE & BOUNDARY SECTION BASEMENT FIRE EXIT STAIR - DETAILS
SCALE: 1 : 50 SCALE: 1 : 20
CLIENT: Hunter Hopkins PROJECT: INFINITY
www.chriscloutdesign.com.au GENERAL NOTES:
Use written dimensions only. DO NOT scale drawings. Contractors SITE ADDRESS: Lot1-RP66483 & Lot1-RP70165,217-219 Gympie Terrace, Noosaville 4567
PO BOX 135, NOOSAVILLE, QLD 4566 to verify all dimensions on site prior to commencing works. Site
E: [email protected] location in accordance with engineers details. These drawings are to DRAWING TITLE: STAIR DETAILS (FIRE ESCAPE)
P: (07) 54748 107 be read in conjunction with engineers design and details, the
accompanying building specification and schedule of finishes. If in DATE: 07/08/19 SCALE:As indicated
@ A2 DRAWN BY: DWL
F: (07) 54748 108 BSA LICENCE: 1127508
doubt, please request clarification. DO NOT ASSUME. ISSUE: MINOR CHANGE AMENDMENT SET
C71.1 [B]