   PO41                                                             AO41                                                           Compliant
   All premises and access routes are clearly identifiable to all   All premises are identified by the provision of the street     Street numbering can be prominently displayed as part of
   persons, particularly emergency services personnel.              number in a prominent location, preferably near                the proposed development.
                                                                    the site entry, (i.e. on the kerb or letterbox or by signage
                                                                    on the building or site).

   PO42                                                             AO42.1                                                         Compliant
   Building entries are visible and easily identifiable.            The number of entrances and exits are limited and              The proposed development limits building entrances/exits,
                                                                    main building entrances/exits are located at the front of      which are located at the frontages of the site, in view from
                                                                    the site in view of the street. Where this is not possible,    the street.
                                                                    due to site or existing building constraints, a well-defined
                                                                    path is provided to the entrance/exit.

                                                                    AO42.2                                                         Compliant
                                                                    All entrances/exits to buildings, are well lit and signed,     The proposed development will ensure all entrances/exits
                                                                    and signage includes hours of operation.                       are well lit and signed.


                                                                    AO42.3                                                         Not Applicable
                                                                    Entrances/exits are located to provide a direct link to        No onsite car parking areas are proposed as part of this
                                                                    driveways and car parking areas.                               development application.

                                                                    AO42.4                                                         Compliant
                                                                    Recessed doorways are avoided where the recess is of           Recessed doorways are avoided or otherwise sufficiently
                                                                    sufficient size to conceal a person or where recessed          sized to avoid concealment of persons.
                                                                    doorways are unavoidable, the following measures are
                                                                    used to enhance safety:
                                                                    a) good lighting;
                                                                    b) strategically placed mirrors;
                                                                    c) angled approaches; or
                                                                    d) gates which restrict access.

   Vandalism                                                        AO43                                                           Compliant
   PO43                                                             Buildings or structures that are visible or accessible from    The proposed development employs appropriate graffiti
   Buildings and structures are designed to minimise                a public street or laneway:                                    and vandalism control in its design.
   opportunities for vandalism.                                     a) avoid the use of solid fences and blank walls which
                                                                         attract graffiti. Where solid blank surfaces are
                                                                         unavoidable, measures in the form of landscaping,
                                                                         creepers, murals, vandal resistant paint, etc. are
                                                                         used;
                                                                    b) with windows at ground level use measures that
                                                                         deter break and enters without obscuring views to
                                                                         shopfronts; and


Ref: 204099.T003                                                                                                                                                                      Page 13
214 David Low Way
PEREGIAN BEACH QLD 4573
Log in to download the original file

Appendix 2 - Code Assessment.pdf · 950 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.