Original source · versioned page text
191001_05.2_Civil Drwgs
Attached to the e-mail Operational Works Application OPW21/0189 - DA Form 1 Application Driveway crossovers & Stormwater Discharge connection 13-15 Hilton Esplanade Tewantin.
EXISTING DRIVEWAY
REMOVED AND REPLACED
WITH KERB AND CHANNEL
1 2 3 4 5
NO FILL
LEGEND
INSTALL 600 X 600 STORMWATER
B.E.L BULK EARTHWORKS LEVEL PIT. CONNECT TO EXISTING
ACCESS PIT WITH Ø150 PIPE.
PROPOSED BLOCKWORK RETAINING WALL - REFER C101. PROPOSED ROOF WATER
TO CONNECT TO NEW PIT
PROPOSED TIMBER FENCE (SL 2.00 : IL 0.45)
EXISTING PROPERTY BOUNDARIES POOL NO FILL
PROPOSED ROOF WATER DRAINAGE 2.500
FILL DEPTH
VARIES
PROPOSED STORMWATER DRAINAGE (0 - 1.000m)
1.900
B.E.L 1.900m
PROPOSED 300 x 300 DRAINAGE PIT A (NOMINAL FILL
INSTALL 600 X 600 DEPTH 0.900m)
STORMWATER PIT
FALL DIRECTION
WITH Ø100 PIPE
1.900 SPOT LEVEL
BULK EARTHWORKS 1.900
FILL (DEPTH VARIES) IN YARD AREAS NO FILL
FILL TO RL 1.875 UNDER BOAT SHED
FILL TO RL 2.475 UNDER BUILDING PAD C
EXISTING POINCIANA TREE
TO BE RETAINED C101 E
FILL TO RL 1.900 AROUND POOL UNDER DECKS C101
FILL TO DRIVEWAY SURROUNDS B.E.L 2.475m
(NOMINAL FILL
NEW DRIVEWAY GENERALLY IN DEPTH 1.475m)
ACCORDANCE WITH IPWEAQ 2.100
STANDARD DRAWING RS-050. D
REFER C101 FOR LONG SECTION. C101
A
TO STREET
DRIVEWAY
C101 (TO GARAGE)
REMOVE EXISTING YARD DRAINAGE
B
NO FILL
AIN
TO REM
AINAGE
EXISTING PALM TREES 1.000
TO BE RETAINED
2.500 2.500 2.000
YARD DR
2.100
EXISTING
F.S.L TO MATCH DRIVEWAY C
C101 2.250
RECENT GRATED INVERT PIT
2.150
BUILT BY COUNCIL 2020
1.300
C D
C101
NEW DRIVEWAY GENERALLY IN DRIVEWAY
B.E.L 1.875m FILL DEPTH
ACCORDANCE WITH IPWEAQ B (TO BOAT SHED)
(NOMINAL FILL VARIES
STANDARD DRAWING RS-050. C101 DEPTH 0.875m) (0 - 1.500m)
REFER C101 FOR LONG SECTION.
2.250
D
1.350
STORMWATER DRAINAGE PIT (IL 0.80)
PROPOSED STORMWATER
DRAINAGE TO CONNECT TO
EXISTING GULLY PIT (IL 0.48)
Ø150 PVC Ø150 PVC Ø150 PVC
J:\2019\19630bd2_New_Residence_13_and_15_Hilton_Esp_Noosa\4.CADD\#ACAD\19630_CIVIL.dwg
NO FILL TIMBER FENCE TOE OF BATTER
(2.1m HIGH)
GENERAL ARRANGEMENT PLAN
SCALE 1:100 AT A1 0 1 2 3 4 5m
1:100 (A1) 1:200 (A3)
COPYRIGHT © Associated Consultants Client Drawn Verified Project Drawing Title Scale Sheet Size
JC JF
This drawing is subject to
copyright in accordance with P & R TAYLOR TAYLOR RESIDENCE GENERAL ARRANGEMENT PLAN AS SHOWN A1
the agreement between TOD Designed Verified
Consulting Pty Ltd (tc) and tc's JF DR 13-15 HILTON ESPLANADE, TEWANTIN Drawing Number
client. This drawing shall only
be used for this specific project.
C 27.08.20 ISSUED FOR APPROVAL DR
Approved RPEQ No RP DESCRIPTION 19630-C100
This drawing shall not be used Noosa: 07 5449 9600 Sunshine Coast: 07 5329 3190 D. REYNOLDS 9072 LOCAL AUTHORITY NOOSA COUNCIL
B 14.07.20 ISSUED FOR APPROVAL DR MCU APPROVAL HORIZ DATUM 0 10 20 30 40 50 60 Sheet Revision
for construction until marked as PO Box 61, Noosaville, QLD 4566 Signed
A 02.03.20 ISSUED FOR APPROVAL JC [email protected] www.todconsulting.com ROL APPROVAL VERT DATUM
'Issued For Construction' in the
revision description. Rev Date Revision Description Drawn ABN 39 128 805 336 27.08.20 OPW APPROVAL RL DATUM MEASUREMENT BAR - INCREMENTS IN mm 3 of 4 C
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.