Council archive · source document
132006.268.03 - Original Court Approval - Attachment 1
| DIR = = design irrigation rate in mm/week
Therefore:
qw = 3,367L (from Table 5.1.1) x 7 days
t = 23,569L/week
ro DIR = 20mm/week (adopted from Global
' Testing report in Section 3)
I Ai = 23,569/20 = 1,180m?
| Assuming the conservative DIR of
20mm/week determined above, a minimum
| of 1,180m? is required for irrigation.
| Drawing number HJ0085.1.5 shows the
proposed redevelopment layout and
proposed irrigation area locations.
5.7 Buffer distances
Code (2007)*):
Secondary treated effluent
© 6m from an in-ground rainwater tank
used as a potable water supply for
i humans or animals.
* 30m from a dam, bore, weil or
permanent watercourse (embankment).
{ * 30m from an intermittent watercourse
(embankment) or drainage channel
t provided that they are not
. directly/indirectly used as a potable water
| supply for humans or animals.
* 6m from the water's edge of swimming
[ pool when located lower than the
: disposal area or 3m when higher (must
| also be outside of the pool enclosure).
t
~S800fH
ge wgI>”
a
and Wastewater Code’ (2007).
{ To protect downstream environmental
| values and prevent potential human health
impacts, the following setback distances
apply for effluent irrigation areas
L . (Queensland Plumbing and Wastewater
t
8 Queensland Department of Local Government,
Planning, Sport and Recreation ‘Queensland Plumbing
GILBERT+SUTHERLANG
© 4m from property boundaries, pedestrian
paths, footings of buildings, walkways,
recreation areas or retaining wall
footings and the like when focated
downslope from the disposal area, or 2m
when upslope or level.
For public health reasons the disposal areas
must have signage in accordance with
AS/NZS 1547:2000.
5.8 Additional buffer requirement
Further to the above recommended setback
distances the Noosa Shire Plan Planning
Scheme Policy 24 - Effluent Disposal
(effective February 3, 2006) requires that all
effluent disposal irrigation areas are to be
located not less than 100m from any
permanent or intermittent watercourse.
To this end it is proposed that the irrigation
area for this site will be located near the
western fot boundary to the south of the
access road, See Drawing No.HJ0085.1.6 (at
the end of this section).
5-3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
132006.268.03 - Original Court Approval - Attachment 1.pdfRelated documentApplication case desk ↗
About this file
- File size
- 6.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.