Original source · versioned page text
Approved Plans - MCU22-0116, OPW22-0173 RAL22-0014
The original of this document is very large (10.8 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Original PDF page 15, section 1. The text section number identifies this passage in the reader.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn -
APPROVED PLAN
MCU22/0116, OPW22/0173
& RAL22/0014
NOOSA COUNCIL
5 JANUARY 2023
A-3 A-2 A-1 B-3 B-2 B-1
-13°
86°
Q2100 10% AEP HGL
DATUM RL 21.00 22.00
COVER (& NATURAL SURFACE) LEVEL 29.30 (29.25) 29.30 (28.98) 27.95 (27.81) 29.30 (29.53) 29.30 (29.29) 29.30 (29.02)
DEPTH TO INVERT 0.35 0.71 1.10 0.13 0.35 0.60 0.62 0.85
28.67 28.31
HYDRAULIC GRADE LINE 29.05 28.41 27.91 29.19 29.05 28.80 28.57
INVERT LEVEL 28.95 28.59 28.20 27.83 28.95 28.70 28.68 28.45
PIPE CHAINAGE -9.52 9.00 18.72 -16.45 -0.92 13.81
PIPE LENGTH L=18.52 L=9.71 L=15.54 L=14.73
PIPE SIZE (mm) 150 (2x)75x125 150 150
PIPE GRADE (%) 1.94% 3.81% 1.61% 1.53%
PIPE GRADE (1 in) 1 in 51.4 1 in 26.3 1 in 62.1 1 in 65.5
PIPE COVER MINIMUM Cover=0.20 Cover=0.12 Cover=0.20 Cover=0.39
PIPE CLASS Class=uPVC SN10 Class=PVC Class=uPVC SN10 Class=uPVC SN10
PIPE ROUGHNESS n=0.013 n=0.013 n=0.013 n=0.013
Vcap - CAPACITY VELOCITY (m/s) Vcap=1.20 Vcap=1.41 Vcap=1.09 Vcap=1.07
Vc - CRITICAL DEPTH VELOCITY (m/s) Vc=0.97 Vc=1.03 Vc=0.96 Vc=1.17
Vn - NORMAL DEPTH VELOCITY (m/s) Vn=1.26 Vn=1.32 Vn=1.16 Vn=1.21
Vf - FULL PIPE VELOCITY (m/s) Vf=0.72 Vf=0.89 Vf=0.71 Vf=1.04
Qcap - CAPACITY FLOW (L/s) Qcap=21 Qcap=26 Qcap=19 Qcap=19
Q - PIPE FLOW (L/s) Q=13 Q=17 Q=13 Q=18
Qi - PIT INFLOW (L/s) & CHOKE (%) Qi=13 Qi=4 Qi=13 Qi=6
Ku (& Kw) - PIT LOSS FACTORS 0.00 2.07 (2.52) 5.24 0.00
PIT TYPE INSP PIT INSP PIT KERB ADAPTOR INSP PIT INSP PIT INSP PIT
1019.02E 1015.03E 1015.05E 1033.29E 1029.89E 1015.33E
PIT SETOUT 4989.76N 4971.67N 4961.96N 4984.62N 4969.46N 4971.70N
29.30Z 29.30Z 27.81Z 29.30Z 29.38Z 29.30Z
ROAD NAME &
ROAD CHAINAGE & OFFSET
LINE A LINE B
SCALE: CLIENT: APPROVED BY: PROJECT NAME:
RESIDENTIAL DUPLEX AT 22 DELORME ST
AS SHOWN TITLE: STATUS:
STORMWATER DRAINAGE ISSUED FOR APPROVAL
© ABN 89 647 469 707 C 21/10/22 REISSUED FOR APPROVAL MVP BRP NW SANTIAGO NOMINEES NATHAN WAGSTAFF SECTIONS
B 12/06/22 REVISED ARCH LAYOUT BRP BRP NW
37 MARY ST RPEQ: 26443
A 19/05/22 MCU ISSUE BRP BRP NW
NOOSAVILLE, QLD 4566 CPEng NER DRAWING NUMBER: PROJECT NUMBER: REV:
+61 7 5211 1003 REV DATE DESCRIPTION DWN CHK APP SHEET
DATE: 21/10/22 SIZE:
RECORCONSULTING.COM REVISIONS C44 20220130 A1 C
Document Set ID: 22234486
Version: 1, Version Date: 09/01/2023
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.