SUPERSEDED - Compiled Approved Plans - MCU15-0109.04
The original of this document is very large (34.6 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn rev date issued details
Working Drawings
SK Plans... B 23.08.2017 RS Working Drawings
Legend
refer to schedules for details
Note:
all structural elements; including all
slabs, columns, beams, footings and - BLOCK 7
north BLOCK 12
framing; to be in accordance with
engineer's design and detail. APPROVED PLANS
BLOCK 8
BAL# !
CLA# !
Balustrade Type
Cladding Type
MCU15/0109 BLOCK 9
BLOCK 11
FLF#!
REN# !
Floor Finish Type
Blockwork Finish Type NOOSA COUNCIL BLOCK 10
west
21 SEPTEMBER 2017
RFS#! Roof SystemType
east
SCN# ! Screen Type
BRE! Breeze Blocks
CT! Cooktop
DP! Downpipe
FFL! Finish Floor Level south
GD! Grated Drain
HWS! Hot Water System
REF! Refrigerator
S! Sink
SHR! Shower
SOL! Solar Array
ST! Storage
VB! Vanity basin
OV! Oven
BTH! Bathtub
WM! Washing Machine
8m height limit
top of roof
CLA2 CLA2 RL+17,396
CLA1 fall 5 deg
1,910
1,910
ceiling first floor
RL+15,490
2,600
2,600
2,600
7,890
window hood first floor
380
RL+12,890
CLA3
2,460 380
380
3,000
BAL2 BAL2 SCN1 existing ground line
RL+9,510 RL+9,510
3,000
CLA3 ground floor
RL+8,710 RL+8,710 BAL2 BAL1 REN2 RL+10,050
REN2 RL+9,510
800 REN1
540
300mm thick wall pool footing refer to eng spec
S10 South Block 10 E10 East Block 10
Scale 1:200 Scale 1:200
8m height limit
RFS2 8m height limit
SOL RFS2 SOL
RFS1 top of roof
fall 5 deg RL+17,396
CLA2 CLA2 RFS1
1,910
1,910
380 2,600
ceiling first floor
RL+15,490
CLA1
380 2,600
360
2,600
window hood CLA3 CLA3
7,890
540 2,460
first floor
RL+12,890
2,100
existing ground line
RL+10,050 RL+10,050
3,000 380
existing ground line SCN1
540 2,460
390
390
390
SCN1 SCN1 BRE with REN2 under
REN2 REN2 CLA3 ground floor
BAL2 RL+10,050
800
BAL1
RL+9,510
RL+8,710
pool
800
800
800
N10 North Block 10 W10 West Block 10
Scale 1:200 Scale 1:200
a: shop 5, 212 david low way, peregian beach, qld 4573
p: (07) 5471 3033 Parkridge Villas Scale 1:200
sparks architects www.sparksarchitects.com
Precinct F Development, Noosa Springs Altum Constructions 119 RS Elevation Block 10 WD 2.8
sparks architects pty. ltd. abn 89 124 611 721
qld architect's registration No. 3974 project client job no. drawn drawing dwg no.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.