Log in to see the plans as drawnTreatment Train
Specifications
Regardless of the system type, the media filtration system
Performance Specification shall consist of the following components;
The stormwater filtration treatment train shall consist • Inlet energy dissipation
of x 200 micron gully pit basket/s and x • Cartridge section
460/690mm passive, siphon-actuated, radial flow, self • Outlet section to bypass storm flows and convey
cleaning media filtration cartridge system/s operating at a treated stormwater
specific flow rate of not more than 1.5L/s/m2.
• Access Lids in roof slab for access to Cartridges
• Siphon actuated cartridges filled with proprietary
The gully pit basket system shall consist of the
ZPG™ filter media
following components;
• Specific flow rate of each individual cartridge limited
• Removable 200 micron Nylon monofilament Precision
not to exceed 1.5L/s/m2
woven Filtration Bag
• Air Lock Cap complete with one way Air Valve Flap
• Fixed Galvanised Mesh Cage (no greater than 80mm x
• Outer Hood complete with Scrubbing Regulators
80mm) around the Filtration Bag
• Automated high-energy turbulence on the screen face
• Recycled modified ABS plastic to seal the unit into the pit
(only) at the end of storm flows to flush pollutants from
• By-pass mechanism above the Filter with no moving parts
the cartridge
• System rigidly fixed to the walls of the pit.
• Centre Drainage Tube complete with Buoyancy Float
The media filtration system shall be located within the • Individual Cartridge Flow Restrictor Disc
following structure.
• ¼ Turn Bayonet Fittings
• Manhole • Under drain manifold to convey treated stormwater to
• DownPipe the receiving environment.
• Linear
• Vault
• Large Box
• Detention.