NOTES:
unit 13, the hastings, noosa parade 1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE AUSTRALIAN
DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH AS 1684.2 2010
RESIDENTIAL TIMBER FRAMING MANUAL.
3. PINE FRAMING TO BE MINIUMUM STRESS GRADE MGP 10/MGP12
NO 4.HARDWOOD FRAMING TO BE MINIMUM STRESS GRADE F14 & MINIMUM
JOINT GROUP J2.
OS 5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
SPECIFICATIONS ALL OTHER FIXINGS TO BE IN ACCORDANCE WITH
A AS 1684.2 2010
PA 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN TABLES WHERE
OTHER BRANDS ARE USED, SIZES TO BE CONFIRMED WITH
MANUFACTURERS SPECIFICATIONS.
RA 8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
9. BUILDER AND TRADES ARE TO CONFIRM ALL MEASUREMENTS, DETAILS
DE AND SPECIFICATIONS PRIOR TO SETOUT AND ORDERING OF MATERIALS
10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER AS NO
45.07 RESPONSIBILITY WILL BE TAKEN AFTER CONSTRUCTION HAS COMMENCED
0 11. ALL TRADES ARE TO CONFORM WITH THE CURRENT AUSTRALIAN
STANDARDS RELATING TO HIS OR HER OWN WORK
12. TERMITE PROTECTION TO BE PROVIDED AS PER AS 3660.1.2000
DOMESTIC SMOKE ALARMS:
1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED WITH
PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE WITH BUILDING FIRE
SAFETY LEGISLATION AMENDMENT REGULATION 2016
6600
2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE WITH AS
5400
1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL AND INTERCOM
UNIT 14 SYSTEMS.
3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD WIRED
existing timber fence (EXISTING DWELLINGS ONLY) THAT CANNOT BE
600
REMOVED FROM DEVICE
129.360
NOTE: SMOKE ALARMS TO BE INSTALLED IN ALL HALLWAYS AND BEDROOMS
TO EXISTING RESIDENCE
UNIT 13 -
NOOSA COUNCIL
APPROVED PLAN
51983.3225.08 5 APR 2017
(PROPOSED BUILD IN)
62.648
site plan
PROPOSED: CLIENT: JENIFER BASHFORD BUILDER: MICK GARDNER MANDY'S DESIGN & DRAFTING SHEET: 1 of 4 DATE: ISSUE NO:
BUILD IN GROUND+ALTERATIONS PH: 0412 104 710 PH: 0414 697 882 PH: 0403 481 474 SCALE: 1:100 MAR 2017 C
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 2 pages
Page 2
NOTES:
unit 13, the hastings, noosa parade 90 90 90
1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE AUSTRALIAN
DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH AS 1684.2 2010
elevation C
04 of 04 RESIDENTIAL TIMBER FRAMING MANUAL.
810 2280
04 of 04 3. PINE FRAMING TO BE MINIUMUM STRESS GRADE MGP 10/MGP12
01 4.HARDWOOD FRAMING TO BE MINIMUM STRESS GRADE F14 & MINIMUM
elevation B JOINT GROUP J2.
70 70 70 5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
store under 01 1630 1010 3730 6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
proposed bath/l'dry SPECIFICATIONS ALL OTHER FIXINGS TO BE IN ACCORDANCE WITH
0606AW
existing AS 1684.2 2010
90 tub 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN TABLES WHERE
u/bench wms
620
+ dryer over
OTHER BRANDS ARE USED, SIZES TO BE CONFIRMED WITH
pantry
kitkitchen to be renovated MANUFACTURERS SPECIFICATIONS.
2/520
1950
2520
8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
shr
9. BUILDER AND TRADES ARE TO CONFIRM ALL MEASUREMENTS, DETAILS
existing cross bracing
AND SPECIFICATIONS PRIOR TO SETOUT AND ORDERING OF MATERIALS
720
(door size to 10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER AS NO
RESPONSIBILITY WILL BE TAKEN AFTER CONSTRUCTION HAS COMMENCED
90
UP be confirmed)
11. ALL TRADES ARE TO CONFORM WITH THE CURRENT AUSTRALIAN
EXISTING cabinetry to be confirmed STANDARDS RELATING TO HIS OR HER OWN WORK
by owner/builder
2121OXSD
CARPORT 12. TERMITE PROTECTION TO BE PROVIDED AS PER AS 3660.1.2000
3300
0315OXSW
2600
(tiles)
DOMESTIC SMOKE ALARMS:
existing 90x90shs posts 1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED WITH
90
PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE WITH BUILDING FIRE
0315OXSW 01 SAFETY LEGISLATION AMENDMENT REGULATION 2016
2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE WITH AS
3290 3380 01 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL AND INTERCOM
SYSTEMS.
3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD WIRED
(EXISTING DWELLINGS ONLY) THAT CANNOT BE
REMOVED FROM DEVICE
Ground Floor First Floor
elevation A
01 04 of 04
NOTE: SMOKE ALARMS TO BE INSTALLED IN ALL HALLWAYS AND BEDROOMS
TO EXISTING RESIDENCE
existing existing -
T NOOSA COUNCIL
T
APPROVED PLAN
51983.3225.08 5 APR 2017
720
720
S
S
bed
bed
01
proposed floor
elevation D
04 of 04 Upper Floor
PROPOSED: CLIENT: JENIFER BASHFORD BUILDER: MICK GARDNER MANDY'S DESIGN & DRAFTING SHEET: 3 of 4 DATE: ISSUE NO:
BUILD IN GROUND+ALTERATIONS PH: 0412 104 710 PH: 0414 697 882 PH: 0403 481 474 SCALE: 1:100 MAR 2017 C
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
Page 3
NOTES:
unit 13, the hastings, noosa parade 1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE AUSTRALIAN
DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH AS 1684.2 2010
RESIDENTIAL TIMBER FRAMING MANUAL.
3. PINE FRAMING TO BE MINIUMUM STRESS GRADE MGP 10/MGP12
4.HARDWOOD FRAMING TO BE MINIMUM STRESS GRADE F14 & MINIMUM
JOINT GROUP J2.
5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
UPPER FLOOR TOP PLATE SPECIFICATIONS ALL OTHER FIXINGS TO BE IN ACCORDANCE WITH
UPPER FLOOR JOINERY AS 1684.2 2010
7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN TABLES WHERE
OTHER BRANDS ARE USED, SIZES TO BE CONFIRMED WITH
MANUFACTURERS SPECIFICATIONS.
2400
8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
9. BUILDER AND TRADES ARE TO CONFIRM ALL MEASUREMENTS, DETAILS
UPPER FLOOR AND SPECIFICATIONS PRIOR TO SETOUT AND ORDERING OF MATERIALS
FIRST FLOOR TOP PLATE 10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER AS NO
RESPONSIBILITY WILL BE TAKEN AFTER CONSTRUCTION HAS COMMENCED
FIRST FLOOR JOINERY LINE 11. ALL TRADES ARE TO CONFORM WITH THE CURRENT AUSTRALIAN
STANDARDS RELATING TO HIS OR HER OWN WORK
2400
12. TERMITE PROTECTION TO BE PROVIDED AS PER AS 3660.1.2000
FIRST FLOOR DOMESTIC SMOKE ALARMS:
GROUND FLOOR TOP PLATE 1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED WITH
GROUND FLOOR JOINERY LINE PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE WITH BUILDING FIRE
awning window SAFETY LEGISLATION AMENDMENT REGULATION 2016
2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE WITH AS
2400
1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL AND INTERCOM
SYSTEMS.
GROUND FLOOR 3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD WIRED
100
(EXISTING DWELLINGS ONLY) THAT CANNOT BE
PAD LEVEL
REMOVED FROM DEVICE
vertical timber cladding alike existing
elevation A elevation B NOTE: SMOKE ALARMS TO BE INSTALLED IN ALL HALLWAYS AND BEDROOMS
TO EXISTING RESIDENCE
UPPER FLOOR TOP PLATE
UPPER FLOOR JOINERY
2400
UPPER FLOOR
bed
FIRST FLOOR TOP PLATE
FIRST FLOOR JOINERY LINE
2400
FIRST FLOOR kit
GROUND FLOOR TOP PLATE
GROUND FLOOR JOINERY LINE
u/side of joists
2300
2400
vj lined and painted
proposed
between joists, nominal height to 90mm timber framing + cladding
u/side of lining 2400 over alike existing
GROUND FLOOR
slab and footings as required
Section 1 -
elevations
NOOSA COUNCIL
APPROVED PLAN
51983.3225.08 5 APR 2017
elevation C elevation D
PROPOSED: CLIENT: JENIFER BASHFORD BUILDER: MICK GARDNER MANDY'S DESIGN & DRAFTING SHEET: 4 of 4 DATE: ISSUE NO:
BUILD IN GROUND+ALTERATIONS PH: 0412 104 710 PH: 0414 697 882 PH: 0403 481 474 SCALE: 1:100 MAR 2017 C
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH