NOTES GENERAL 1, 2. Wind Classification W41N/N3 All work to conform to the current Building Code of Ausiralia- Class 1 & with AS1684.2 Residential Timber Framed Construction-N3 as applicable fo the work. The Builder shail check all dimensions, levels& details before excavation, construction & ordering. Report discrepancies to designer. Do not scale. drawings. The drawings and specifications shall be considered complementary, and any work and/or materials absent from one but present or implied in the other shall be furnished as if they were present in both. Drawings shall be read in conjunction with consuitants drawings. All work, materials & associated fixing methods shall conform to respective manufacturer's specifications & Australian Standards as applicable to the work. Construction shall not proceed before approval in writing has been received from both the Building Certifier & Council as applicable. It is the obligation of the contractor and / or plumbing contractor to survey alll existing services prior to construction. No footing, or wall to encroach the title boundary. . All proprietary waterproofing systems to be installed in accordance with the manufacturers recommendations. Plumbing to be caitied out by a licensed plumber and in accordance with the requirement of local authorities. the contractor shall be responsible for all permits and approvals. all hot water lines shall be fully insulated. Sanitary plumbing shall be connected to existing system with materials approved by the focal authority. Termite protection to be carried out in accordance with AS3660.1Termite Management- New Building Vehicle crossing / residential driveways to comply with RS-49 & RS-50 (RS-56 for rural Driveways) STORMWATER DRAINAGE yr. All stormwater runoff is to be directed to 90mm dia PVC downpipes to connect to an approved ouilet in accordance with AS3500.3 or to-water tanks as per Council Guidelines The control of stormwater pollution from the building site shall be carried out in accordance with the “Best Practice Guidelines”. WIND CLASSIFICATION W41N/N3 GROUND FLOOR BRACING NOTES s=—= M12 Bracing Sets < REQUIRED 109.58 kN PROVIDED 140.00 KN A REQUIRED 158.07 KN PROVIDED 180.0 kN 7 7 i 1 ' 1 po a e ok 20kN |Z R 5 ° i | zg R °. |Z R 20kN rr a oy ° i 1 ! [rs 4 [ne -l ng goon oe TOKN T0kN 20kN TOkN i lg j= ayaa Tt ° ° bd NK LEPTIN i i | | 4 20kN . ° z g z 8 HN ° NOTE THE BUILDER SHALL CHECK ALL DIMENSIONS, LEVELS & DETAILS BEFORE EXCAVATION, CONSTRUCTION & ORDERING. REPORT DISCREPANCIES TO EBIS. IF IN DOUBT -ASK! 20KN 20kN bw ene ee ee ee 20kN r SUB FLOOR BRACING PLAN 90mm TIMBER WALL FRAME ON BLOCKWORK LOAD BEARING WALL (MGP12) Top plate Bottom plate 90 x 35 not notched 90 x 35 not notched Studs 90 x 35 at 450 cts Nogging 90 x 35 1350 max cts JOIST TO TOP PLATE ]-framing anchor. 4-2.8 dia nails each leg. ORIGINAL ISSUE 24.41.2022 Engineering & Building Investigation Services Unit 1/4 Textile Ave, Warana Proposed Alterations / Raising of Existing Residence 0 Box 973 Buddina 4575 at Lot 31 (No. 81) Lake Flat Road Boreen Point Phone 07 54369199 Fax 07 54369198 E: [email protected] Client: Robert Killeen BRACING PLAN Drawing No. A3-220221-S1 Scale: 1:100 NOVEMBER 2022 Drawn: HS Checked: Edy
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.