Original source · versioned page text
Appendix F - Survey
Original PDF page 2, section 1. The text section number identifies this passage in the reader.
90.27 90.18
0°00' Colorbond fence
90.29 90.23 90.13
90.20
14
D (C)
2
//
//
Steel shed 89.89
RP35096 90.19 90.16 SP316907
21 90.18 90.17
90.01
90.08 90.04 90.00
P5015
90
75.901
CP
165° //
D (C)
56.93
SP316907
26'
1
//
90.10 89.92
90.16
S (D)
90.08 90.05
D (C)
90.14 90.08 89.97
22
P5015 LEGEND:
S (D)
Road Terrain
//
//
90.13 90.15 90.07 Kerb Back Driveway
D (C)
Kerb Invert Footpath
89.89 Edge of Bitumen Slab Edge
90.06 90.05
Gravel 89.93 Edge of Gravel Retaining Wall Base
Timb
89.97
C (D
) Pad Road Crown Retaining Wall Top
Traffic Park Meter Change of Grade
S (D)
er fe //
C (D 90.07 Traffic Light Top of Bank
) 90.14 90.08 Traffic Pit Toe of Bank
D (C)
90.12 Traffic Sign Waterline
nce
C (D
)
SW Field Inlet:
Traffic Post Box Garden Edge
D) Creek Toe of Bank
IL: 89.559 S( Structures
//
C (D Type: 100 PVC Building Line Creek Top of Bank
)
Roof Ridgeline Creek Invert
S (D)
90.15 90.15 90.00 Fence Line Creek Waterline
90.11 90.08 90.03 D)
S( Gate Tree
Hand Rail Tree Canopy
Sewer MH:
Cattle Grid Control Point/PSM
D) Bollard
S(
//
(Unable to open) 89.96 Drainage
IL: 88.45 (from records) Sewer Pipe: Sewer D(*) Drainage line
Type: 160 PE-100 (Abandoned)
S(*) Sewer Line Open Drain
S (D)
//
90.05 n
rde S(
D) Valve Manhole
90.13
90.07 Ga Inspection Opening Field Inlet
90.14 S (D) S (D) Manhole Downpipe
90.18 S (D) S (D) S (D) S (D) //
)
S (D) Communications
S (D
S (D) S (D) S (D) Electrical
90 E(*) Electricity Line C(*) Communication Line
Sewer MH: Garden 89.86
EOH Overhead Line TOH Overhead Line
*Plotted from records*
IL: 88.58 (from records) Sewer MH: 89.98 Pits/Manholes Pits/Manholes
S (C)
Type: 160 PE-100 (Unable to open) // Pole Pillar
IL: 87.32 (from records) 90.02 Street Light Gas
//
Type: 160 PE-100 89.84
)
Light In-Ground Gas Line
S (D
G(*)
T6 Water Valve
90.23 W(*) Water Line Marker
90.19 T7
T8 // Meter General
Valve Pothole
S (C)
T14
H Fire Hydrant
Timber fence
Tap Subsurface Utility - QL
)
S (D
//
T13 Sprinkler * (A) * QL-A (H±50mm,V±50mm)
Garden T15 T29
T30 Fuel * (B) * QL-B (H±300mm,V±500mm)
//
4 P(*) Fuel Line * (C) * QL-C (H±300mm,2D)
.23 ' Fitting * (D) * QL-D (Exist Record)
40
°51
S (C)
89.84 /
/ 23 8 T27
)
S (D
90.16
Scale 1:250 T12 1 NOTES:
90.15 T11 // T16 RP35098 1. Drawn to scale on an A3 sheet.
//
)
S (C)
T26
89.93 2. Contour Interval... 0.25m
S (D
0m 5 10 15 20 25 T10 //
T28 89.50 3. All levels are in metres on the Australian Height
89.49 Datum referred to (PSM154817) - RL 92.282 AHD
n ce 89.53 situated in RECTORY ST POMONA.
T9 r fe 89.59
be 90 4. All Boundaries are vide title and subject to
90 Tim f Bank
)
Bottom o
S (D
confirmation by survey.
S (C)
//
89.82
89.71 5. The Location of Underground services are in
//
S (D) S (D) S (D)
89.94
90 S (D) accordance with AS5488:2019, the Australian
S (D) S (D) 89.76 S (D)
S (D) S (D)
S (D)
S (D) 90.39 Standard for classification of Subsurface Utility
S (D) Information (SUI). The exact nature and location
S (D)
S (D) 90.45 90.38
S (D) 90.49 T24 of these services should be confirmed prior to
S (D) 90.48 90
90.45 T22 construction.
90.17
Top of Bank
Sewer MH: T23 6. Area vide title : 1868m²
(Unable to open) T20 T21 T25
90 7. Field Survey Completed on 09/08/2024 & 23/10/2024
IL: 87.04 (from records) T18
T17
T19 89
Type: 160 PE-100 88.78
88.95 88.86
88.99
88.99
88.77
89.06 Bottom of Bank 89.03
88.77
88.96 D (D)
D (D)
88.94 88.69 D (D)
89 D (D)
89.05 88.98 88.65 D (D) Level datum: AHD Derived ((PSM154817))
88.99 88.68 D (D)
D (D)
D (D) Horiz datum: PLAN ((RP35096))
D (D) D (D) 88.79
D (D)
D 88.81
D (D) D (D) D (D) 88.79 (D) Coord Origin: Arbitrary ((NW Cor Site))
D (D)
D (D)88.84
D (D) D (D) D (D) D (D) 88.91 GDA System: Not Applicable Coordinate System: Plane 1:1
88.77
Channel 89 88.94 Meridian: + 0°00'00" RP35096
89.01 89.01 88.97 88.96
89.07 89.05 89.06 89
Title:
89.05 89.09
89.25
VERIFICATION PLOT
89.11
89.17 Bottom of Ban
k 89.51
89.60
89.55 Lot 14 on RP35096
89.79 89.64
89.70
89.87 89.69 5 School Street, Pomona
Top of Bank
90
90.10 89.94 89.87
90.01 90.00 89.96 89.82
Client: Rowan Anderson
Unsealed Bitumen Driveway Locality: Pomona
Rifle Street Local Gov: Noosa Shire Council
C (D) C (D) C (D) C (D) C (D) C (D) C (D) C (D) C (D) C (D) C (D) C (D) C (D) C (D) C (D) C (D) C (D) C (D) C (D) C (D) C (D) C (D) Surveyed By: WA Approved: CJ
Date Created: 23/10/24 Scale: 1:250
W (D) W (D) W (D) W (D) W (D) W (D) W (D) W (D) W (D) W (D) W (D) W (D) W (D) W (D) W (D) W (D) W (D) W (D) W (D) W (D) W (D) W (D) File Ref: 241221
Plan No: 241221_002_VER Rev: A
Page 2 of 3 A3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.