ELECTRICAL CONTRACTOR LEGEND: ELECTRICAL
24 24
0L
0L
V V The works detailed on this drawing shall be constructed in accordance with Robin Russell & Associates' EXISTING UNDERGROUND CABLE
LV SWITCHBOARD LABELS AT VISION COURT(STN 3_) SC2069511 General Specification for Installation of Electricity Reticulation and Street Lighting - Issue 'Y'.
Lot 8 240LV 240LV U71339 CIRCUIT LABEL LABEL LETTER
LABEL INFORMATION PROPOSED UNDERGROUND CABLE
4SL
No. SIZE COLOUR SIZE
CIVIL CONTRACTOR
M80 14 240LV
TRANSF. PROPOSED NBN CONDUIT ON COMMS ALIGNMENT
ISOLATOR 80x35 WB 6 TRANSFORMER ISOLATOR The installation of all electrical conduits shall be supervised by the holder of an electrical work licence
A/B/C - Electrical Safety Act 2002.
24 24
0L 4S 4SL
COMMS CONDUIT IN SHARED TRENCH
0L V L
V
40(11
)
_
Energex conduits and transformer site retaining walls shall be installed strictly in accordance with
2 1 80x35 WB 5
Energex's specifications (see below). They will be inspected for compliance upon completion. BORED CONDUIT
Lot 7 240(1
1)
The civil contractor shall install enveloping conduits under retaining walls behind pillars - two 100mm GAS IN SHARED TRENCH
GATEWAY DVE
240LV EX 1 80x35 WB 5 _ conduits into each lot (one for Electricity, one for Telstra), 600mm deep behind the pillar, near ground
EX EX VENTURE DRIVE S70
level inside the lot. 12 STATION NUMBER
S70 S70
2 80x35 WB 5 _
Relevant specifications in Energex's Underground Distribution Construction Manual are found at - C PADMOUNT TRANSFORMER
Section C1: Conduits
PROPOSED POLE TRANSFORMER
EX Section C2: Excavation
Lot 6 S70 240LV
Section C3: Transformer Sites
L
2 80x35 WB 5 _ METER BOX / LV SWITCHBOARD
4S
These sections of the manual can be downloaded from the following Energex web site:
240LV Lot 13 http://www.energex.com.au/about_energex/asp/technical_documents.asp PROPOSED SERVICE PILLAR
TO VISION CRT (SOUTH) U1332699
240LV 3 80x35 WB 5 FIT NEW
240LV
240(11)
& SERVICES Civil engineers who have registered for access to the following RRA website may download extracts
24
240(11) EXISTING SERVICE PILLAR
V
0L
0L
24
240LV
1)
V
from Energex's manual at:
24
0(1
0L 240(11)
V
24
V
0L
TO VISION CRT (SOUTH) U1332699 http://www.robrus.com.au FUTURE SERVICE PILLAR
1)
11
24
DANGER 3 80x35 WB 5 FIT NEW
0(1
1 U71341 & SERVICES
24
V
The civil contractor shall ensure that all conduits have been installed before constructing retaining
1)
240L
240LV LIVE LV & HV
240(1
A/B/C EXISTING LINK PILLAR
240(11) A/B/C CABLES walls, paths, driveways & water services. The civil contractor shall please inform the electrical
TO VISION CRT (STH/WEST) U1332704
4 80x35 WB 5 FIT NEW contractor of any 'as constructed" departures from the civil design. PROPOSED C&I PILLAR
Lot 12 & SERVICES
Lot 5 M80 10
4SL
240LV
9 3 SC2069511 TO VISION CRT (STH/WEST) U1332704 Care! Lighting of new or altered existing roads might not comply with specified standards
EXISTING OVERHEAD ELECTRICITY MAINS
A/B/C A/B/C EX 4 80x35 WB 5 FIT NEW
240(11)
S70
1 & SERVICES until new road lighting has been commissioned. The civil contractor shall ensure that PROPOSED OVERHEAD ELECTRICITY MAINS
IN 2x240LV
Lot 11 necessary warning signs are installed and speed restrictions are applied if necessary.
SC1389563
MATERIAL: GRAVOPLY II (1.5mm) or similar HV POLE
) 2 ENERGEX REQUIRE 2 X LV LABELS AT TRANSFORMERS.
ON-SITE SERVICES CHECKS
(11 HV + LV POLE
95 1A 40LV 0LV
A/B/C
240LV
24
Lot 4 0L
V
8
2
JOIN TO EXISTING Robin Russell & Associates gives no warranty regarding the presence or location of buried services,
24
6 LV or STREET LIGHT POLE
7 CONDUITS STN 1A including newly-installed services. "As Constructed" locations may differ from what is drawn on this
25m
A/B/C N
A/B/C A/B/C U71343 500kVA PMT CCT1 CCT2 CCT3 CCT4 works plan. Contractors shall be responsible to identify and locate all buried services. Initial PROPOSED STREET LIGHT
4 identification can be obtained from:
240LV EXISTING STREET LIGHT
Dial Before You Dig Service
N
V
5 24
0L
Telephone 1100 FUTURE UNDERGROUND STREET LIGHT
3
COURT
240LV
Fax 1300 652 077
N
N
A/B/C RECOVER STREET LIGHT
LOT 12 Lot 10 On-line enquiries can be made at:
http://www.1100.com.au. EARTH
240LV 2
6 6L
S70 Having determined which services may be present, on-site locations should then be arranged with EXISTING RATE 3 STREETLIGHT CABLE
relevant service authorities.
Lot 3 240LV
PROPOSED RATE 3 STREETLIGHT CABLE
9 Sewerage and water plans for the subdivision may be obtained on request from the Superintendent.
7 LV SWITCHBOARD EXISTING RATE 3 STREET LIGHT
N
240LV LAYOUT FOR SC2069511 (STN 3) - VISION CRT INSTALLATION OF TELECOMMUNICATIONS CONDUITS BY TELSTRA PROPOSED RATE 3 STREET LIGHT
N
LOT 11 9L Telstra's contractor will install telecommunications conduits in shared trenches and other excavations
S70
240LV N
8L provided by the electrical contractor. In commercial subdivisions, or where more than 2xP100 conduits EXISTING CONSUMERS OVERHEAD CABLE
S70
N
VISION S70 Lot 8
are required, the conduits may not be installed above Energex conduits. They shall be laid in a PROPOSED CONSUMERS OVERHEAD CABLE
4SL
Z DEVELOPERS SURVEYOR separate trench on the standard communications alignment specified.
240LV
TO INSTALL LINE PEG BEHIND NEW LABELS EXISTING CONSUMERS UNDERGROUND CABLE
Contractors shall notify Telstra's contractor:
10m
4SL O PILLAR STN 8 TO SATISFY ENERGEX
REQUIREMENTS. one week before road crossing trenches will be open. PROPOSED CONSUMERS UNDERGROUND CABLE
two days before footpath trenches will be open.
8 ROCK WALL ON BOUNDARY PROPOSED CONSUMERS SWITCHBOARD
Lot 2 10 Telstra's contractors are:
PATHWAY
south of Brisbane River: Silcar Communications EXISTING CABLE
3m PILLAR
elsewhere: Service Stream Communications
PROPOSED CABLE
O 4SL
BIKE PATH CLEARANCES
32/40mm HD CONDUIT
5 4 "Austroads Guide to Road Design Part 6A: Pedestrian & Cyclist Paths" specifies a minimum
A/B/C U1389568 clearance of 0.5m between a bike path and any obstacle. In order to achieve specified road/ 80/100mm LD CONDUIT
S70 A/B/C TELSTRA - NOTE SC21257 path lighting within the specified verge, it has not been possible to satisfy that requirement.
SEPERATE TRENCHING IS REQUIRED 100mm WHITE ENERGEX COMMS. CONDUIT
S/L 21m
U2071825
FOR TELSTRA CONDUITS IN
Lot 1 COMMERCIAL INDUSTRIAL SUBDIVISIONS. 125mm LD CONDUIT
CABLE MARKER POST
EX
U1389567 240AL
"ENERGEX ELECTRIC CABLE" MARKER PLATE
EX
240AL
GATEWAY DVE
LP2071830
EX.
UNDERGROUND CABLE CERTIFICATION
(OPEN)
U2071832 240L
V
EX EXISTING All cables detailed on this drawing have been checked using the
-20m 0 20 40 60m 185CU
PLAN VIEW VENTURE DRIVE
U4199324
cable locator described below and are, according to measurements
SCALE 1:1000 See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 2 sections
Section 2
EX.
SC754851 taken, on the correct alignment and at correct depths below the
1 : 1000 (A1 - NOT REDUCED) 240LV finished level, except as marked up. Alignments are subject to the
accuracy of survey pegs present at the time of measurement.
EX EX. EX
EX. 240AL 240AL 240AL
240AL Make: ____________________ Model: _______________________
U453522
LP2071827 Serial No: ____________ Date Cables Checked: _____/_____/_____
AVENUE
(OPEN) 3
SC2069511 Name of Person Who Conducted Checks: _______________________
EX Certified (signature of checker): _______________________________
1 240AL
COURT
PROJECT
SC1389563 CCT3 Phone No. of checker: ______________________________________
LP1004619
IN 80 IN
64 240AL (EX. OPEN)
EX. 240AL
ROAD LIGHTING CERTIFICATE
VISION
240AL CCT3 15/5/08
EX.
6 Within the bounds of this estate, this road lighting design is certified to
240AL
9
comply generally with the nominated categories of AS1158.1-1986,
7 2
31 AS/NZS1158.1.1:2005 and/or AS/NZS1158.3.1:2005 for luminaires
44 U1332699 and lamps supplied under Energex contract C10227.
49 31
U1389565 VISION COURT - CATEGORY P4
10 IN
8
240AL
U1332704 PROPOSED COMMISSIONING PLAN
Tentative only; subject to amendment by ENERGEX outage coordinator. ROAD LIGHTING MAINTENANCE SCHEDULE
This design assumes maintenance factors of 0.7 for minor road
LV ONLY lighting and 0.75 for major road lighting. These maintenance factors
Where interruptions to existing consumers are required, they shall be notified are based on the following nominal maintenance schedule, which
GATEWAY DRIVE
in line with ENERGEX policies. might not necessarily be adopted by Energex.
CONSTRUCTION CONTACTS TELECOMMUNICATIONS INFRASTRUCTURE 1. Lamps shall be replaced at 36-month intervals.
2. At that time, luminaires shall be cleaned, inspected & maintained.
ELECTRICAL ENGINEER CONDUITS & PITS to be designed by: Telstra's contractor 3. Vegetation shall be kept clear of street lights.
ROBIN RUSSELL & ASSOCIATES PTY LTD to be installed by: Telstra's contractor 4. Inspection patrols and spot lamp replacement shall maintain
DESIGNER LP1389559 to be owned by: service availability at not less than 95%.
ANTHONY HOBBS ph: 0499 993515 LV SCHEMATIC TELECOMMUNICATIONS INFRASTRUCTURE to be provided by: 5. Luminaires and lamps shall be replaced with exact equivalents.
CONSTRUCTION MANAGER
(SCALE 1:2000)
SHANE HYDE ph: 0419 021772 Telstra AFR: -
CIVIL ENGINEER Robin Russell RPEQ 1546
TOD NOOSA CONSULTING ENGINEERS
DOUG REYNOLDS ph: 5449 9600
SOURCE DOCUMENTS SITE INFORMATION
SURVEYOR
CREATOR DRAWING DWG. NO. REV. NO. DATE TOTAL NUMBER OF LOTS
MURRAY & ASSOCIATES PTY LTD (GYMPIE)
7
JOHN CAMPBELL ph: 5441 2188 TOD NOOSA CONSULTING ENGINEERS PROPOSED WATER 06583/21 T1 26/3/2008
PROPERTY DESCRIPTION
TELSTRA CONTRACTOR TOD NOOSA CONSULTING ENGINEERS BASE ACAD..06583 EMAIL 17/3/2014 LOTS 2-8 cancelling P/O LOT 81 ON SP211687
ISGM
TOD NOOSA CONSULTING ENGINEERS ROADWORKS & DRAINAGE - 6583-5A 17/3/2014
BOB TANNER ph: 0477 708028
ENERGEX
DATE REV REVISION APP. DATE REV REVISION APP. CURRENT REVISION CHANGES: SPECIFICATION
SWP47.1 DESIGNED A. HOBBS DESCRIPTION LOCATION DRAWING No.
SUBDIVISION ELECTRICAL SERVICES
27/3/2014 A PRELIMINARY ISSUE R.R.
Robin 204/6 Babarra Street,
Stafford, QLD 4053
COUNCIL S.C.R.C. DRAWN C. TODHUNTER ELECTRICITY RETICULATION GATEWAY RISE NOOSAVILLE - STAGE 2 B080-01B
15/05/2014 B COUNCIL APPROVAL R.R.
Russell Tel: (07) 3872 5555
Fax: (07) 3872 5566
COUNCIL REF OPW 14/0147 APPROVED BY ROBIN RUSSELL
RPEQ 1546
GATEWAY DRIVE & VENTURE DRIVE
& ASSOCIATES PTY. LTD. Email: [email protected]
www.robrus.com.au
UBD REF
Map
18
Grid
E1
SIGNED
CLIENT
NOOSAVILLE FOR TENDER ENERGEX PROJECT No. SHEET No.
A1 S0104663 1 2
CONSULTING ENGINEERS - ELECTRICAL A.B.N. 78 010 589 661
GATEWAY RISE PTY LTD THIS DOCUMENT IS COPYRIGHT AND THE PROPERTY OF ROBIN RUSSELL & ASSOCIATES PTY LTD OF
DWT REV V26 - 20140225 DATE 15/05/2014 C AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT AUTHORITY.
Section 3
ENERGEX
DATE REV REVISION APP. DATE REV REVISION APP. CURRENT REVISION CHANGES: SPECIFICATION
SWP47.1 DESIGNED A. HOBBS DESCRIPTION LOCATION DRAWING No.
SUBDIVISION ELECTRICAL SERVICES
27/3/2014 A PRELIMINARY ISSUE R.R.
Robin 204/6 Babarra Street,
Stafford, QLD 4053
COUNCIL S.C.R.C. DRAWN C. TODHUNTER ELECTRICAL SCHEDULES GATEWAY RISE NOOSAVILLE - STAGE 2 B080-02B
15/05/2014 B COUNCIL APPROVAL R.R.
Russell Tel: (07) 3872 5555
Fax: (07) 3872 5566
COUNCIL REF OPW 14/0147 APPROVED BY ROBIN RUSSELL
RPEQ 1546
GATEWAY DRIVE & VENTURE DRIVE
& ASSOCIATES PTY. LTD. Email: [email protected]
www.robrus.com.au
UBD REF
Map
18
Grid
E1
SIGNED
CLIENT
NOOSAVILLE FOR TENDER
ENERGEX PROJECT No. SHEET No.
A1 S0104663 2 2
CONSULTING ENGINEERS - ELECTRICAL A.B.N. 78 010 589 661
GATEWAY RISE PTY LTD THIS DOCUMENT IS COPYRIGHT AND THE PROPERTY OF ROBIN RUSSELL & ASSOCIATES PTY LTD OF
DWT REV V26 - 20140225 DATE 15/05/2014 C AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT AUTHORITY.