Development Application - Part 1 of 4 - IDAS Form 1 & 6

of 13

Page text read automatically using OCR, there may be inaccuracies

                                                                                                                    .
                                                                                                                       "    l._y
                                                                                                                           r.
                                                                                                                            ,




  ODD
Applications for operational works involving stormwater drainage

drawings showing:                                                                         D confirmed
.
   existing and proposed contours
.
   drainage locations, diameters and class of pipe, open drains and easements
.  manhole location, chainage and offset or co-ordinates and inlet and outlet
   invert levels
.  inlet pit locations, chainage and offset or co-ordinates and invert and kerb
   levels

Applications for operational works involving water reticulation

drawings showing:                                                                         D confirmed
.  kerb lines or edge of pavement where kerb is not constructed
.  location and levels of other utility services where affected by water
   reticulation works
                                                                                                       .J

.
   pipe diameter, type of pipe and pipe alignment
.  water main alignments

.  water supply pump station details (if applicable)

.  minor reservoir details (if applicable)

.  conduits
.  location of valves and fire hydrants
.  location of house connections (if applicable)
.  location of bench marks and reference pegs

Applications for operational works involving sewerage reticulation
drawings showing:
                                                                                          D confirmed
.  location of all existing and proposed services
.  location of all existing and proposed sewer lines and manhole locations

.  location of all house connection branches
.  kerb lines or edge of pavement where kerb is not constructed
.
   chainages
.  design sewer invert levels
.
   design top of manhole levels
.
   type of manhole and manhole cover
.
   pipe diameter, type of pipe and pipe alignment
.  location of house connections (if applicable)
.sewer      pump station details (if applicable)

Applications for operational works involving street lighting
drawings showing:
                                                                                          D confirmed
.  location of all light poles and service conduits
.  location of all other cross road conduits

.
   type of wattage and lighting
.
   any traffic calming devices
.  additional plans for roundabouts and major roads (if applicable)
.  details of any variations to normal alignment
.  details of lighting levels




               "1                            Building nr opera/iollal work ilssessable against i1 planning ~(heme-IDAS form 6
                                                                                              Version 1.0 18 December 2009


[OCR of page images]
LO

 

Applications for operational works involving stormwater drainage

 

drawings showing:

e existing and proposed contours

e drainage locations, diameters and class of pipe, open drains and easements

e manhole location, chainage and offset or co-ordinates and inlet and outlet
invert levels

e inlet pit locations, chainage and offset or co-ordinates and invert and kerb
levels

| confirmed

 

Applications for operational works involving water reticulation

 

drawings showing:

e kerb lines or edge of pavement where kerb is not constructed

e location and levels of other utility services where affected by water
reticulation works

e pipe diameter, type of pipe and pipe alignment

e water main alignments

© water supply pump station details (if applicable)

¢ minor reservoir details (if applicable)

e conduits

e location of valves and fire hydrants

¢ location of house connections (if applicable)

e location of bench marks and reference pegs

LE] confirmed

 

Applications for operational works involving sewerage reticulation

 

drawings showing:

e location of all existing and proposed services

e location of all existing and proposed sewer lines and manhole locations
e location of all house connection branches

e kerb lines or edge of pavement where kerb is not constructed
e chainages

e design sewer invert levels

e design top of manhole levels

e type of manhole and manhole cover

e pipe diameter, type of pipe and pipe alignment

e location of house connections (if applicable)

© sewer pump station details (if applicable)

| confirmed

 

Applications for operational works involving street lighting

 

 

drawings showing:

e location of all light poles and service conduits

e location of all other cross road conduits

e type of wattage and lighting

e any traffic calming devices

e additional plans for roundabouts and major roads (if applicable)
e details of any variations to normal alignment

e details of lighting levels

 

| confirmed

 

 

—IDAS form 6
Version 1.0 18 December 2009

 

Log in to download the original (Development Application - Part 1 of 4 - IDAS Form 1 & 6.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.