Att 2 - BAL Report

Attached to the e-mail 002892 - MCU26_0047 - 122 Musa Vale Road_ Cooroy - Information Response.msg.

of 27
                                                                                                  ABN 82 617 701 210
                                                                                   [email protected]
                                                                                    www.bushfireassessmentqld.com.au
                                                                                                 Phone: 0418 799 818


     4. CONSTRUCTION REQUIREMENTS / CONCLUSIONS

4.1. BAL Rating

The BAL rating for the subject site has been calculated to be BAL-12.5. Shielding is not applicable for this
rating per clause 3.5 of AS3959-2018. As such the proposed new secondary dwelling, and associated
infrastructure, will need to comply with Section 3 and Section 5 of AS3959-2018.

It is vital to point out that this rating is only applicable for the separation distances (refer Table 2) being
maintained in perpetuity. Any change/s to any of these, or the proposed new secondary dwelling, and
associated infrastructure location will necessitate a recalculation of the BAL rating.

4.2. Maintenance of separation distances

The separation distances between the structure/s and the identified Vegetation Plots can be referred to as
an Asset Protection Zone (APZ). An APZ is a cleared area surrounding the structure/s where the minimum
distance is measured on a horizontal plane from the nearest part of the external wall/supporting column or
stair of the structure to the edge of the unmanaged vegetation. An APZ is to be maintained in perpetuity;
information on how to maintain an APZ is explained in the NSW Fire Service guide – Standards for Asset
Protection Zones, available from:

https://www.rfs.nsw.gov.au/__data/assets/pdf_file/0010/13321/Standards-for-Asset-Protection-Zones.pdf

This BAL rating is given on the assumption that an APZ of a minimum distance of 19.9m will be maintained
around the proposed dwelling in a manner as recommended by the guide, refer Figure 6 and Appendix B.




Bushfire Assessment Queensland ©                                                                                 17

Log in to download the original (Att 2 - BAL Report.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.