Council archive · source document
130814 Acoustic Report 230913 · MCU13/0171
Cooroy Property Trust Pty Ltd c/- Lavin Trading Environmental Noise Level Study for Proposed Wimmers Soft Drink Manufacturing Facility, 271 Lake Macdonald Drive, Lake Macdonald Page 15 of 32 APPENDIX A: AMBIENT NOISE LEVEL MEASUREMENTS Measurement Equipment The following equipment was used to conduct the ambient noise level study at Monitoring Location A: • Bruel and Kjaer Type 2260I Modular Precision Sound Analyzer – Observer – Serial No. 2409371, with Type BZ 7220 Software and Prepolarised free-field ½” microphone, Type 4189, Serial No. 2395445; • Bruel and Kjaer Type 3592 outdoor microphone kit, including Type UA1404 outdoor microphone; • Bruel and Kjaer Type AO 0442 ten metre microphone extension cable; and • Bruel and Kjaer Type 4231 Sound Level Calibrator, Serial No. 2292736. All of the above equipment is Type 1 in accordance with the requirements of Australian Standard AS 1259-1990, Acoustics – Sound Level Meters, as required by Australian Standard AS 1055.1-1997. Measurement Equipment Settings The above equipment was used with the following settings: • Detector: RMS • Time Weighting: FAST • Frequency Weighting: A • Sound Incidence: FRONTAL • Microphone sensitivity: -26.1 dB • Range: 10-90 dB. Calibration The sound level meter was calibrated to the required value of 93.8 dB at 1000 Hz immediately before and after the noise level measurements were conducted. At no time was an adjustment of more than ±0.5 dB required. This complies with the requirements of the Australian Standard. Monitoring Location Monitoring Location A was at the southern end of the site, just to the north-east of the existing office building on the property, with the microphone elevated 1.8 metres above ground level. This monitoring location would have a similar ambient noise level to all of the surrounding residences, due to the rural/residential nature of the area and minimal traffic on Lake Macdonald Drive. Refer Figure 1 for further details. Atmospheric Conditions Throughout the ambient noise level study, atmospheric conditions complied with the requirements of the Australian Standard. David Moore & Associates Pty Ltd Our reference: R13095/D2847/Rev.0/23.09.13
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
130814 Acoustic Report 230913Related documentApplication case desk ↗
About this file
- File size
- 2.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.