Council archive · source document
130814 Acoustic Report 230913 · MCU13/0171
Cooroy Property Trust Pty Ltd c/- Lavin Trading Environmental Noise Level Study for Proposed Wimmers Soft Drink Manufacturing Facility, 271 Lake Macdonald Drive, Lake Macdonald Page 5 of 32 CRITERIA Measurements and Calculations All noise level measurements were conducted in accordance with the following: • general requirements of the Queensland environmental protection legislation; • Environmental Protection (Noise) Policy 2008; • Brisbane City Council City Plan 2000; rd • Noise Measurement Manual, Queensland Government – Environmental Protection Agency, 3 Edition, March 2000; and • Australian Standard AS 1055.1-1997, Acoustics – Description and Measurement of Environmental Noise, Part 1, General Procedures. Noise Limits The noise sources associated with the soft drink manufacturing facility are either steady state or time- varying. Steady state noise could include airconditioning units, fans, pumps, cooling towers, etc whilst time varying noise sources include on-site vehicle activities, forklifts, etc. In accordance with Hassall, J R & Zaveri, K, Acoustic Noise Measurements, Bruel & Kjaer, Denmark, January 1979: “… The following short table shows the subjective effects of changes in noise levels. Change in Noise Level Subjective Response 3 just perceptible 5 clearly perceptible 10 twice as loud … “ For time-varying noise sources, the selected noise limit criteria should ensure that the existing acoustic amenity does not significantly deteriorate. From the above reference, a change in noise level of 5 dB(A) is clearly perceptible, whereas a change of 3 dB(A) is only just perceptible. On this basis, the noise limit for time-varying noise is that, for like parameters, the source noise level combined with the ambient noise level should not exceed the ambient noise level by more than 3 dB(A), after due consideration of tonality and impulsiveness. For the night-time, the noise limit criteria is that of the World Health Organisation document Guidelines for Community Noise, 1999: “… For a good sleep, it is believed that indoor sound pressure levels should not exceed approximately 45 dB(A) LAmax more than 10-15 times per night. …” This is the noise limit that has been adopted for the night-time period and is assessed for inside the closest residences (whereas the time-varying noise limits for daytime and evening are external to the residences. For steady-state noise, the commonly applied residential noise limit criteria are as follows: • daytime (0700 to 1800 hours): background + 5 dB(A) • evening (1800 to 2200 hours): background + 5 dB(A) • night-time (2200 to 0700 hours): background + 3 dB(A) David Moore & Associates Pty Ltd Our reference: R13095/D2847/Rev.0/23.09.13
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
130814 Acoustic Report 230913Related documentApplication case desk ↗
About this file
- File size
- 2.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.