Skip to the record
NoosaWatch™: The source of truth.

Council archive · source document

Att 1 - Amended Architectural Plans · 132001.210164.1

of 15

Check the original when the exact wording matters.

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRICAL & MECHANICAL ENGINEER :

ID D D D D D D
2A.01 2A.02 2A.03 2A.04 2A.05 2A.07
DESCRIPTION SWING DOOR SWING DOOR SWING DOOR SWING DOOR SWING DOOR SWING DOOR SWING DOOR
NOTES SOLID CORE SOLID CORE SOLID CORE
g g Z| g g g g
& & g § & § &
| .REVISEDLEVEL 1FLOORLEVEL {| 0 a ee ee a ee ee Se Ee — —.—.—.—
RL 7.680
y 920 y y 920 y Y 820 y Y 820 y Y 820 y y 920 y y 920 y
ID D D
2A.08 2A.09
DESCRIPTION SWING DOOR SWING DOOR
NOTES
2 3
R g
| _ REVISED LEVEL 1 FLOOR LEVEL _ pe |
RL 7.680
920 920
/at\ DOOR SCHEDULE
(J LEVEL 1 - STAGE 24 SCALE 1:50
- CONFIRM ALL DOOR SIZES ON SITE PRIOR TO MANUFACTURER.
- ALL NEW INTERNAL AND FRONT ENTRY DOOR CLEARANCES, DOOR
HARDWARE, OPENING FORCES, AND LUMINANCE CONTRAST
REQUIREMENTS ARE TO BE IN COMPLIANCE WITH AS1428.12009.
- BRAILLE AND TACTILE SIGNAGE TO COMPLY WITH SPECIFICATION D3.6
OF NCC.
- PROVIDE LIFT OFF HINGES TO ALL SANITARY COMPARTMENTS WHERE
THE DOORS DO NOT OPEN OUTWARDS OR SLIDE.
- SIGNAGE IS REQUIRED TO A FIRE ISOLATED STAIRWAY DOOR ON THE
SIDE OF THE DOOR THAT FACES THE PERSON SEEKING EGRESS. SIGNS
ON THE DOORS ARE TO COMPLY WITH PART D2.23 OF BCA.
- DOORS IN A REQUIRED EXIT, FORMING A PART OF A REQUIRED EXIT, OR
IN A PATH OF A REQUIRED EXIT, MUST BE READILY OPENABLE
WITHOUT A KEY. OPERATION OF LATCH TO COMPLY WITH PART D2.21
OF BCA.
FG FIXED GLASS
FRL FIRE RESISTANCE LEVEL
HC HOLLOW CORE
KP KICK PLATE
PC POWDER COAT
sc SOLID CORE
VP VIEWING PANEL
NOTE OPENING ARROW POINTS TO HANDLE SIDE
NOT FOR CONSTRUCTION
CHECKED -............ coves
notes : issue | revision log by date issue | revision log by date consultants: project:
. : A | CONSULTANT ISSUE Na | 14-05-25 date: APR 23
1. The designs, drawings and specication are A] CONSULTANT ISSUE NO) 14-09-29 STRUCTURAL ENGINEER : JK N PROPOSED ALTERATIONS & ADDITIONS, ; Na
copyright and always remain the property o! company name! rawn:
Blackburne Jackson Design Pty Ltd. PH : Inumber] [Gemail here] 5/11 KINGFISHER DRIVE PEREGIAN BEACH
CIVIL ENGINEER : ARCHITECTURE | LANDSCAPE | INTERIOR | PROJECT MANAGEMENT client: checked: NK
2. Before commencing construction: [company name]
- Verify all dimensions and levels. PH : [number] [email here] PEREGIAN BEACH SURF LIFESAVING CLUB Inc. scaleA1: 1:50
- Verify location and levels of all services on site. HYDRAULIC ENGINEER : 37 Aerod Rd M hydore Qld .
- Verify that floor levels and finished levels will [company name] erodrome aroochydore title: scale@A3: 1:100
enable connection to services. PH : [number] [email here] P.O. Box 154 Cotton Tree QLD 4558 phone 07 5443 3200 DOOR SCHEDULE STAGE 2 project/drawing no. sheet: A

 

. Do not scale this drawing.

When in doubt refer to Architects.

 

 

 

 

 

 

 

 

 

[company name]

PH : [number] [email here]

 

 

email mail(@blackburnejackson.com.au fax 07 5443 4030

 

 

5766 _A09-01_B

 

 

5766-27-Peregian Surf Club ALTUM_STAGE 2.pin printed: Tuesday 20 May 2025 1:26PM

Used in these records

About this file

File size
2.2 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Att 1 - Amended Architectural Plans.pdf · 2.2 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.