Code Assessment
Attached to the e-mail MCU16/0066 & OPW16/0133 Plan of Development, Noise report & survey (4 of 4).
column 1 column 2 Proposal Complies
Specific Outcomes Probable solutions (if code
assessable)
any additional loading.
Sloping sites
O15 On sloping sites, buildings and S15.1 Buildings are of split Not applicable. N/A
structures are designed to maximise the level design that step down
use of natural slope and minimise the the slope or have suspended
need for cut and fill. floor construction; (See
Figure Error! No text of
specified style in
document..1below)
AND
S15.2 Cut or fill is less than
1.5m in depth;
AND
S15.3 The distance between
the ground and the lowest
part of the floor of the
building does not exceed 3m.
o Figure Error! No text
of specified style in
document..1—Design for
sloping site (suspended
floor)
Roof form
O16 Roof forms— S16.1 The main roof of the The proposed roof forms will contribute positively to Yes
a) contribute positively to the local building has a roof pitch no the skyline.
skyline; less than 12 degrees and
b) complement the low rise character of has roof overhangs a
the locality; minimum of 600mm wide;
c) use simple traditional roof designs, AND
such as hipped, gabled or skillion; S16.2 Building and structures
and do not include rooftop
132