Residential Uses Code
Privacy
O14 For Multiple Housing Types 2, 3 and 4, S14.1 Transparent doors and windows are S14.1 – Complies
building and structures are designed and sited to designed and located so they do not directly face Any windows directly facing adjoining windows or
ensure the visual privacy of residents of the transparent doors or windows or the private open private open space can be appropriately screened.
development and neighbouring properties is space areas of other dwelling units within 10
protected. This could be a condition of approval.
metres;
AND
S14.2 – Complies
S14.2 Planter boxes, louvre screens, pergolas,
landscaping and architectural design of balconies Screening vegetation and fences will be provided
are used to screen the ground floor private open to ensure that amenity of the adjoining premises is
space of dwelling units or accommodation units not compromised.
from upper level units (refer to Figure 14-3 Privacy
Measures which illustrates how trees, awnings,
screens, fences and planter boxes reduce
minimise the ability to directly look into
neighbouring homes and yards).
Sloping sites S17.1 Buildings and structures on sloping sites— S17.1 – Not Applicable
O17 On sloping sites, buildings and structures are a) Have a maximum distance of 3m between the The subject site is flat.
designed to maximise the use of the natural ground and the lowest part of the floor of the
topography and minimise the need for cut and fill. building or the building incorporates undercroft
skirting or screening (eg. timber battens) to the full
height of any undercroft area higher than 3m
above ground level at the perimeter of the building;
b) are of split level design that step down the slope
or have suspended floor construction;
c) limit the amount of cut or fill to less than 2m in
depth relative to natural ground level; and
d) do not result in the spread of fill beyond the
footprint of the building and associated batters.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
APPENDIX B - CODE COMPLIANCE.pdfRelated documentApplication case desk ↗
APPENDIX B - CODE COMPLIANCE.pdfRelated documentApplication case desk ↗
About this file
- File size
- 576 KB (small file)
- File type
No other editions are linked here.